scholarly journals Determination of the Spatial Resolution in the Case of Imaging Magnetic Fields by Polarized Neutrons

2021 ◽  
Vol 11 (15) ◽  
pp. 6973
Author(s):  
Wolfgang Treimer ◽  
Ralf Köhler

One of the most important parameters characterizing imaging systems (neutrons, X-rays, etc.) is their spatial resolution. In magnetic field imaging, the spatial resolution depends on the (magnetic) resolution of the depolarization of spin-polarized neutrons. This should be realized by different methods, but they all have in common that a spin-polarizing and spin-analyzing system is part of the resolution function. First a simple and useful method for determining the spatial resolution for unpolarized neutrons is presented, and then methods in the case of imaging with polarized neutrons. Spatial resolution in the case of polarized neutron imaging is fundamentally different from ‘classical’ spatial resolution. Because of π-periodicity, the shortest path along which a spin-flip can occur is a measure of ‘magnetic’ spatial resolution. Conversely, the largest detectable magnetic field (B-field) within a given path length is also a measure of magnetic spatial resolution. This refers to the spatial resolution in the flight direction of the neutrons (Δy). The Δx and Δz refers to the spatial resolution in x- or z-direction; however, in these cases a different method must be used. Therefore, two independent methods are used to distinguish longitudinal and lateral spatial resolution, one method to determine the modulation transfer function (MTF) by recording the frequency-dependent fringe contrast of magnetic field images of a coil (longitudinal spatial resolution), and the second method, to observe the fringe displacement at the detector as a function of magnetic motion, provided that the accuracy of the motion is much better than the pixel size (at least half the pixel size) of the detector (lateral spatial resolution). The second method is a convolution of the fringe pattern with the pixel array of the detector.

2014 ◽  
Vol 70 (a1) ◽  
pp. C882-C882
Author(s):  
Tilman Donath ◽  
Benjamin Lüthi ◽  
Clemens Schulze-Briese

The PILATUS was the first Hybrid Pixel Detector available for SAXS. It has transformed data collection by its photon-counting technology, which enables noise-free X-ray detection with high dynamic range and excellent stability at high frame rates. These properties are essential for superior data quality in all scattering experiments, especially for optimal background correction when studying low-concentration samples. Besides optimal data quality at each sampling point, highest resolution is desired in most SAXS experiments both in q-range and in time. The newly developed EIGER pixel detector more than doubles the q-resolution that can be achieved when compared with PILATUS3 for the same sample-to-detector distance. EIGER features a pixel size of only 75 µm (in comparison: PILATUS3 has 172 µm). To characterize the spatial resolution of these detectors, point-spread functions were measured at the PTB laboratory at BESSY II, which show that the resolution is directly proportional to the pixel size with minimal cross talk between neighboring pixels. The EIGER 1M detector allows data acquisition at up to 3'000 frames per second. This enables unprecedented temporal resolution in time-resolved SAXS measurements and increases the speed of novel imaging techniques such as scanning SAXS/WAXS and coherent diffractive imaging applications, allowing images to be recorded faster or with higher spatial resolution. The design of the EIGER detector makes it vacuum compatible. Operation at low X-ray energies and correspondingly large scattering angles is another way of increasing q-resolution and also gives access to the lowest q data near the beam stop. In-vacuum detectors enable measurements with ultra-soft x-rays and thus high q-resolution. Moreover they optimize the data quality in scattering experiments by removing absorption and scatter caused from air and windows. An in-vacuum PILATUS 1M detector has been installed at the BESSY-2 FCM beamline and is applied for SAXS/GI-SAXS measurements at energies from 1.75 to 10 keV. For simultaneous SAXS/WAXS applications covering an even wider q-range, in-vacuum detectors with L-shaped detection surface are under development. These will detect the WAXS signal, while a clearance in the detector permits the direct beam to pass on to a SAXS detector placed at larger distance. These latest detector developments will be presented along with corresponding experimental results.


2000 ◽  
Vol 179 ◽  
pp. 263-264
Author(s):  
K. Sundara Raman ◽  
K. B. Ramesh ◽  
R. Selvendran ◽  
P. S. M. Aleem ◽  
K. M. Hiremath

Extended AbstractWe have examined the morphological properties of a sigmoid associated with an SXR (soft X-ray) flare. The sigmoid is cospatial with the EUV (extreme ultra violet) images and in the optical part lies along an S-shaped Hαfilament. The photoheliogram shows flux emergence within an existingδtype sunspot which has caused the rotation of the umbrae giving rise to the sigmoidal brightening.It is now widely accepted that flares derive their energy from the magnetic fields of the active regions and coronal levels are considered to be the flare sites. But still a satisfactory understanding of the flare processes has not been achieved because of the difficulties encountered to predict and estimate the probability of flare eruptions. The convection flows and vortices below the photosphere transport and concentrate magnetic field, which subsequently appear as active regions in the photosphere (Rust & Kumar 1994 and the references therein). Successive emergence of magnetic flux, twist the field, creating flare productive magnetic shear and has been studied by many authors (Sundara Ramanet al.1998 and the references therein). Hence, it is considered that the flare is powered by the energy stored in the twisted magnetic flux tubes (Kurokawa 1996 and the references therein). Rust & Kumar (1996) named the S-shaped bright coronal loops that appear in soft X-rays as ‘Sigmoids’ and concluded that this S-shaped distortion is due to the twist developed in the magnetic field lines. These transient sigmoidal features tell a great deal about unstable coronal magnetic fields, as these regions are more likely to be eruptive (Canfieldet al.1999). As the magnetic fields of the active regions are deep rooted in the Sun, the twist developed in the subphotospheric flux tube penetrates the photosphere and extends in to the corona. Thus, it is essentially favourable for the subphotospheric twist to unwind the twist and transmit it through the photosphere to the corona. Therefore, it becomes essential to make complete observational descriptions of a flare from the magnetic field changes that are taking place in different atmospheric levels of the Sun, to pin down the energy storage and conversion process that trigger the flare phenomena.


Author(s):  
J. R. Michael

X-ray microanalysis in the analytical electron microscope (AEM) refers to a technique by which chemical composition can be determined on spatial scales of less than 10 nm. There are many factors that influence the quality of x-ray microanalysis. The minimum probe size with sufficient current for microanalysis that can be generated determines the ultimate spatial resolution of each individual microanalysis. However, it is also necessary to collect efficiently the x-rays generated. Modern high brightness field emission gun equipped AEMs can now generate probes that are less than 1 nm in diameter with high probe currents. Improving the x-ray collection solid angle of the solid state energy dispersive spectrometer (EDS) results in more efficient collection of x-ray generated by the interaction of the electron probe with the specimen, thus reducing the minimum detectability limit. The combination of decreased interaction volume due to smaller electron probe size and the increased collection efficiency due to larger solid angle of x-ray collection should enhance our ability to study interfacial segregation.


Author(s):  
S.I. Woods ◽  
Nesco M. Lettsome ◽  
A.B. Cawthorne ◽  
L.A. Knauss ◽  
R.H. Koch

Abstract Two types of magnetic microscopes have been investigated for use in high resolution current mapping. The scanning fiber/SQUID microscope uses a SQUID sensor coupled to a nanoscale ferromagnetic probe, and the GMR microscope employs a nanoscale giant magnetoresistive sensor. Initial scans demonstrate that these microscopes can resolve current lines less than 10 µm apart with edge resolution of 1 µm. These types of microscopes are compared with the performance of a standard scanning SQUID microscope and with each other with respect to spatial resolution and magnetic sensitivity. Both microscopes show great promise for identifying current defects in die level devices.


2021 ◽  
Vol 13 (10) ◽  
pp. 1958
Author(s):  
Shelly Elbaz ◽  
Efrat Sheffer ◽  
Itamar M. Lensky ◽  
Noam Levin

Discriminating between woody plant species using a single image is not straightforward due to similarity in their spectral signatures, and limitations in the spatial resolution of many sensors. Seasonal changes in vegetation indices can potentially improve vegetation mapping; however, for mapping at the individual species level, very high spatial resolution is needed. In this study we examined the ability of the Israel/French satellite of VENμS and other sensors with higher spatial resolutions, for identifying woody Mediterranean species, based on the seasonal patterns of vegetation indices (VIs). For the study area, we chose a site with natural and highly heterogeneous vegetation in the Judean Mountains (Israel), which well represents the Mediterranean maquis vegetation of the region. We used three sensors from which the indices were derived: a consumer-grade ground-based camera (weekly images at VIS-NIR; six VIs; 547 individual plants), UAV imagery (11 images, five bands, seven VIs) resampled to 14, 30, 125, and 500 cm to simulate the spatial resolutions available from some satellites, and VENμS Level 1 product (with a nominal spatial resolution of 5.3 m at nadir; seven VIs; 1551 individual plants). The various sensors described seasonal changes in the species’ VIs at different levels of success. Strong correlations between the near-surface sensors for a given VI and species mostly persisted for all spatial resolutions ≤125 cm. The UAV ExG index presented high correlations with the ground camera data in most species (pixel size ≤125 cm; 9 of 12 species with R ≥ 0.85; p < 0.001), and high classification accuracies (pixel size ≤30 cm; 8 species with >70%), demonstrating the possibility for detailed species mapping from space. The seasonal dynamics of the species obtained from VENμS demonstrated the dominant role of ephemeral herbaceous vegetation on the signal recorded by the sensor. The low variance between the species as observed from VENμS may be explained by its coarse spatial resolution (effective ground spatial resolution of 7.5) and its non-nadir viewing angle (29.7°) over the study area. However, considering the challenging characteristics of the research site, it may be that using a VENμS type sensor (with a spatial resolution of ~1 m) from a nadir point of view and in more homogeneous and dense areas would allow for detailed mapping of Mediterranean species based on their seasonality.


Author(s):  
Leslie M. Phinney ◽  
Wei-Yang Lu ◽  
Justin R. Serrano

This paper reports and compares Raman and infrared thermometry measurements along the legs and on the shuttle of a SOI (silicon on insulator) bent-beam thermal microactuator. Raman thermometry offers micron spatial resolution and measurement uncertainties of ±10 K. Typical data collection times are a minute per location leading to measurement times on the order of hours for a complete temperature profile. Infrared thermometry obtains a full-field measurement so the data collection time is on the order of a minute. The spatial resolution is determined by the pixel size, 25 μm by 25 μm for the system used, and infrared thermometry also has uncertainties of ±10 K after calibration with a nonpackaged sample. The Raman and infrared measured temperatures agreed both qualitatively and quantitatively. For example, when the thermal microactuator was operated at 7 V, the peak temperature on an interior leg is 437 K ± 10 K and 433 K ± 10 K from Raman and infrared thermometry, respectively. The two techniques are complementary for microsystems characterization when infrared imaging obtains a full-field temperature measurement and Raman thermometry interrogates regions for which higher spatial resolution is required.


1994 ◽  
Vol 50 (10) ◽  
pp. 6774-6778 ◽  
Author(s):  
G. D. Waddill ◽  
J. G. Tobin ◽  
X. Guo ◽  
S. Y. Tong