scholarly journals Adaptive Abnormal Oil Temperature Diagnosis Method of Transformer Based on Concept Drift

2021 ◽  
Vol 11 (14) ◽  
pp. 6322
Author(s):  
Zhibin Zhao ◽  
Jianfeng Xu ◽  
Yanlong Zang ◽  
Ran Hu

The diagnosis of abnormal transformer oil temperature is of great significance to guarantee the normal operation of the transformer. Due to concept drift, the oil temperature abnormal diagnosis of the oil-immersed main power transformer is usually unstable via the classic data mining method. Thus, this paper proposes an adaptive abnormal oil temperature diagnosis method (AAOTD) of the transformer based on concept drift. First, the bagging ensemble learning method was used to predict the oil temperature. Then, abnormal diagnosis was performed based on the difference between the predicted oil temperature and the actual measured oil temperature. At the same time, based on the concept drift detection strategy and Adaboost ensemble learning methods, adaptive update of the base classifier in the abnormal diagnosis model was realized. Experiments validated that the algorithm proposed in this paper can significantly reduce the influence of concept drift and has higher oil temperature prediction accuracy. Furthermore, since this method only utilizes the existing power grid data resources to realize abnormal oil temperature diagnosis without extra monitoring equipment, it is an economic and efficient solution for practical scenarios in the electric power industry.

2014 ◽  
Vol 535 ◽  
pp. 157-161
Author(s):  
Jeeng Min Ling ◽  
Ming Jong Lin ◽  
Chao Tang Yu

Dissolved gas analysis (DGA) is an effective tool for detecting incipient faults in power transformers. The ANSI/IEEE C57.104 standards, the most popular guides for the interpretation of gases generated in oil-immersed transformers, and the IEC-Duval triangle method are integrated to develop the proposed power transformer fault diagnosis method. The key dissolved gases, including H2, CH4, C2H2, C2H4, C2H6, and total combustible gases (TCG), suggested by ASTM D3612s instruction for DGA is investigated. The tested data of the transformer oil were taken from the substations of Taiwan Power Company. Diagnosis results with the text form called IEC-Duval triangle method show the validation and accuracy to detect the incipient fault in the power transformer.


2015 ◽  
Vol 43 (2) ◽  
pp. 211-226
Author(s):  
Sobhy S. Dessouky ◽  
Adel El Faraskoury ◽  
Sherif Ghoneim ◽  
Ahmed Haassan

2012 ◽  
Vol 262 ◽  
pp. 361-366
Author(s):  
Zhuo Fei Xu ◽  
Hai Yan Zhang ◽  
Ling Hui Ren

Roller-mark is a common problem in offset printing and its solution method is important for printing. A new detecting method of texture analysis was given in this paper. In this study, printing image was acquired with high-speed CCD. Compared the difference between printing image and standard image, a defective image was obtained. Then the reason of roller-marks was given by the texture recognition of defect image. Finally, experiments were taken to prove the feasibility and effectiveness of this new method for the roller-marks diagnosis in the offset printing machine.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Nitin K. Dhote ◽  
Jagdish B. Helonde

Dissolved gas analysis (DGA) of transformer oil has been one of the most reliable techniques to detect the incipient faults. Many conventional DGA methods have been developed to interpret DGA results obtained from gas chromatography. Although these methods are widely used in the world, they sometimes fail to diagnose, especially when DGA results fall outside conventional methods codes or when more than one fault exist in the transformer. To overcome these limitations, the fuzzy inference system (FIS) is proposed. Two hundred different cases are used to test the accuracy of various DGA methods in interpreting the transformer condition.


2011 ◽  
Vol 204-210 ◽  
pp. 1553-1558
Author(s):  
Rui Rui Zheng ◽  
Ji Yin Zhao ◽  
Min Li ◽  
Bao Chun Wu

To forecast power transformer fault, this paper proposed a integrated algorithm. Research found that discrete time series of power transformer dissolved gases concentration have 2 main types: the s type and the monotone increasing type. The gray verhulst model was chosen for forecasting the s type series, while the gray model predicted the monotone increasing type data. The two models combined a new integrated forecast model. The fault diagnosis method combines the improved three-ratio method and gray artificial immune algorithm, so it can diagnoses both single and multi power transformer faults, and give the fault location. Experiments show that the power transformer fault forecast algorithm is effective and reliable.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5084
Author(s):  
Mardhiah Hayati Abdul Hamid ◽  
Mohd Taufiq Ishak ◽  
Nur Sabrina Suhaimi ◽  
Jaafar Adnan ◽  
Nazrul Fariq Makmor ◽  
...  

Transformer oil does not only serve as an insulating liquid, but also in removing heat from the windings and cores. Mineral oil (MO) has been widely used in transformers for more than 150 years. Recently, researchers have attempted to search for alternative insulating oils due to the possibility that MO will run out in the future together with the concern on fire safety and environmental pollution. Among the potential oils is rice bran oil (RBO). This work presents the studies of the lightning impulse (LI) of RBO behavior under various electric fields, gap distances and testing methods. The electrical performances of LI tests show that RBO and Palm Oil (PO) have lower LI breakdown voltage than MO under both uniform and non-uniform electric fields. However, the difference in LI breakdown voltages between RBO, PO and MO are slightly small which is less than 20%. In addition, there is no significant effect in the various testing methods under both uniform field and non-uniform field where the percentages of difference are less than 12% and 8% respectively. The data of LI breakdown voltage were statistically analysed to predict the withstand voltage and 50% breakdown voltage of oil samples by using Weibull distribution. The Weibull distribution of MO, PO and RBO has well fit with the fitting line. Finally, the relationship between LI voltages under a non-uniform field with various parameters of PO and RBO was obtained and proposed. From this work, it can be concluded that RBO shows promising results to be considered as an alternative to MO in transformer applications.