scholarly journals Evaluation of the Thermal Performance and Energy Efficiency of CRAC Equipment through Mathematical Modeling Using a New Index COP WEUED

2021 ◽  
Vol 11 (13) ◽  
pp. 5950
Author(s):  
Alexandre F. Santos ◽  
Pedro D. Gaspar ◽  
Heraldo J. L. de Souza

As the world data traffic increasingly grows, the need for computer room air conditioning (CRAC)-type equipment grows proportionally. The air conditioning equipment is responsible for approximately 38% of the energy consumption of data centers. The energy efficiency of these pieces of equipment is compared according to the Energy Standard ASHRAE 90.1-2019, using the index Net Sensible Coefficient Of Performance (NetSCOP). This method benefits fixed-speed compressor equipment with a constant inlet temperature air-cooled condenser (35 °C). A new method, COP WEUED (COP–world energy usage effectiveness design), is proposed based on the IPLV (integrated part load value) methodology. The IPLV is an index focused on partial thermal loads and outdoor temperature data variation for air intake in the condenser. It is based on the average temperatures of the USA’s 29 major cities. The new method is based on the 29 largest cities worldwide and with data-center-specific indoor temperature conditions. For the same inverter compressor, efficiencies of 4.03 and 4.92 kW/kW were obtained, using ASHRAE 90.1-2019 and the proposed method, respectively. This difference of almost 20% between methods is justified because, during less than 5% of the annual hours, the inlet air temperature in the condenser is close to the NetSCOP indication.

2011 ◽  
Vol 19 (02) ◽  
pp. 131-140
Author(s):  
QUBO LI ◽  
DEMISS A. AMIBE ◽  
NORBERT MÜLLER

An air conditioning system using water as refrigerant (R718) that compresses water vapor with multistage stage variable speed axial compressor with intercooling between stages by water injection is considered. Four stage compression with flash intercooling resulted in 50% improvement of coefficient of performance (COP) at full load compared to conventional refrigerants like R134a. The energy efficiency of an air conditioning unit is specified by seasonal energy efficiency ratio (SEER). SEER is defined as the ratio of cooling output of an air conditioner measured and electrical energy consumption as per AHRI 210/240 during cooling season. The SEER is computed after determining the evaporator cooling capacity and the electrical energy demand of the compressor at each bin temperature using assumed compressor isentropic efficiency, mechanical efficiency and electrical efficiency and multiplying by the weight of each bin temperature to determine the total for the cooling season. As a result of multistage compression, best part load performance of water as a refrigerant and operation of compressor near design point at part load due to variable speed drive, 50%–60% improvement in SEER is obtained compared to the best available in the market using conventional refrigerants such as R134a with single stage compression.


Author(s):  
Ajay Landage

A simulation approach to heat pump systems is proposed in this paper. The evaluation of working fluids is conducted. Moreover, the selected refrigerants are used in the simulation. Subsequently, the system is analyzed in terms of the coefficient of performance (COP) and energy efficiency. Some alternative refrigerants, instead of R22 used R290 refrigerent. It is described the selection of refrigerants adapted to each utilization, based on the thermodynamic and -physical properties, the technological behaviour, costs and use constraints as principal aspects of the environmental protection. Also, it is performed a comparative analysis in function of the total equivalent warming impact (TEWI) for some possible substitutes of refrigerant R22 used in various refrigeration and heat pump systems.


Energies ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 5016
Author(s):  
Ioan Sarbu ◽  
Calin Sebarchievici

Ground-coupled heat pumps (GCHPs) are an efficient thermal energy production system that can satisfy the gap between heating and air-conditioning. Be that as it may, exploratory research on GCHPs is still lacking. The first objective of this article is to describe a utilitarian energy-efficiency improvement device for a vertical GCHP system that includes a buffer tank (BT) between the heat pump unit and the fan coil units and user supply, utilizing the quantitative regulation of water flow rate with a variable-speed circulation pump. At that point, the investigative estimations are utilized to test the performances of the GCHP system in various operating modes. Fundamental efficiency parameters (coefficient of performance (COP) and CO2 emission) are achieved for one month of running utilizing two control strategies of the GCHP—standard and optimized regulation of the water pump speed—and a benchmarking of these parameters is achieved. Exploratory research has indicated higher efficiency of the system for the flow regulation solution utilizing a BT and programmed control equipment for the circulation pump speed compared with the standard regulation solution (COPsys with 7–8% higher and CO2 emission level 7.5–8% lower). The second objective is to elaborate a simulation model of the necessary heat/cold in heating and air-conditioning periods, utilizing the Transient Systems Simulation (TRNSYS) program. Finally, the simulation, acquired utilizing the TRNSYS program, is analyzed and compared with experimental information, leading to a good agreement and, along these lines, the simulation model is approved.


Author(s):  
Demiss A. Amibe ◽  
Qubo Li ◽  
Norbert Mu¨ller

An air conditioning system using water as refrigerant (R718) that compresses water vapor with multistage stage variable speed axial compressor with intercooling between stages by water injection is considered. Four stage compression with flash intercooling resulted in 50% improvement of coefficient of performance (COP) at full load compared to conventional refrigerants like R134a. The energy-efficiency of an air conditioning unit is specified by seasonal energy efficiency ratio (SEER). SEER is defined as the ratio of cooling output of an air conditioner measured and electrical energy consumption as per AHRI 210/240 during cooling season. The SEER is computed after determining the evaporator cooling capacity and the electrical energy demand of the compressor at each bin temperature using assumed compressor isentropic efficiency, mechanical efficiency and electrical efficiency and multiplying by the weight of each bin temperature to determine the total for the cooling season. As a result of multistage compression, best part load performance of water as a refrigerant and operation of compressor near design point at part load due to variable speed drive, 50–60% improvement in SEER is obtained compared to the best available in the market using conventional refrigerants such as R134a with single stage compression.


1997 ◽  
Vol 119 (1) ◽  
pp. 62-69 ◽  
Author(s):  
G. Cammarata ◽  
A. Fichera ◽  
L. Mammino ◽  
L. Marletta

In this paper, exergonomic theory is applied to an air-conditioning system for optimization purposes. The investigation is addressed to an all-air system with air recirculation, The thermodynamic cycle includes a mixing plenum, a cooling and heating coil, chiller, and heater. The thermodynamic model is stated according to recent formulations of exergy for moist air streams, while the economic model is based on cost balance equations and real cost data for mechanical equipment. The objective function to minimize includes the following decision variables: fresh to total air rate, coefficient of performance for the chiller, inlet temperature of water for the cooling and the heating coils, temperature difference of the same streams. For the exergonomic optimization, the authors followed the approach proposed by Tsatsaronis (1984). The optimum configuration is obtained through an iterative procedure aimed at the design improvement. The results show that there is considerable room for improvement with respect to a system based on typical design parameters.


Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3303
Author(s):  
Suzane A. Monteiro ◽  
Flávia Monteiro ◽  
Maria E. Tostes ◽  
Carminda Carvalho

The purpose of this article is to develop a methodology to apply to multi-objective optimization algorithms aimed at energy efficiency in buildings, considering aspects such as incremental cost, energy consumption, greenhouse gas emissions and energy efficiency levels of lighting and air conditioning system, according to the mandatory technical regulation in public buildings in Brazil. Presenting a solution to assist in the decision making of engineers, architects or building managers for the optimal arrangements’ choice for lighting and air conditioning equipment, considering each built environment and project profile. For the validation process, a basic building was created with 15 rooms spread over three floors, according to the most common construction parameters in the North of Brazil. First, different combinations of objective-function candidates were investigated to compose the multi-objective algorithm fitness function, analyzing its performance in two central scenarios: (1) adding some “baits” in air conditioning equipment files, and (2) without this inclusion. Thus, it was found that considering only three objective functions—incremental cost, energy consumption and the air conditioning energy efficiency coefficient—it is possible to get optimal non-dominated solutions in both scenarios, thus highlighting the robustness of the proposed methodology.


2020 ◽  
Vol 68 (3) ◽  
pp. 209-225
Author(s):  
Masaaki Mori ◽  
Kunihiko Ishihara

An aerodynamic sound generated by a flow inside a duct is one of the noise pro- blems. Flows in ducts with uneven surfaces such as grooves or cavities can be seen in various industrial devices and industrial products such as air-conditioning equipment in various plants or piping products. In this article, we have performed experiments and simulations to clarify acoustic and flow-induced sound characteris- tics of L-shaped duct with a shallow cavity installed. The experiments and simula- tions were performed under several inflow velocity conditions. The results show that the characteristics of the flow-induced sound in the duct are strongly affected by the acoustic characteristics of the duct interior sound field and the location of the shallow cavity. Especially, it was found that the acoustic characteristics were af- fected by the location of the shallow cavity in the frequency range between 1000 Hz and 1700 Hz.


Processes ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 395
Author(s):  
Feng Cheng ◽  
Boqing Ding ◽  
Xiuwei Li

An absorption air-conditioning system is a good choice for green buildings. It has the superiority in the utilization of renewable energy and the refrigerant is environment-friendly. However, the performance of the traditional absorption system has been restricted by the energy waste in the thermal regeneration process. Capacitive deionization (CDI) regeneration is proposed as a potential method to improve system efficiency. In the new method-based air-conditioning system, strong absorbent solutions and pure water are acquired with the joint work of two CDI units. Nevertheless, the practical CDI device is composed of a lot of CDI units, which is quite different from the theoretical model. To reveal the performance of multiple CDI units, the model of the double/multi-stage CDI system has been developed. Analysis has been made to expose the influence of some key parameters. The results show the double-stage system has better performance than the single-stage system under certain conditions. The coefficient of performance (COP) could exceed 4.5, which is higher than the traditional thermal energy-driven system, or even as competitive as the vapor compression system. More stages with proper voltage distribution better the performance. It also provides the optimization method for the multi-stage CDI system.