scholarly journals Design of a Cell Phone Lens-Based Miniature Microscope with Configurable Magnification Ratio

2021 ◽  
Vol 11 (8) ◽  
pp. 3392
Author(s):  
Xinjun Wan ◽  
Xuechen Tao

Application of cell-phone-based microscopes has been hindered by limitations such as inferior image quality, fixed magnification and inconvenient operation. In this paper, we propose a reverse cell phone lens-based miniature microscope with a configurable magnification ratio. By switching the objectives of three camera lens and applying the digital zooming function of the cell phone, a cell phone microscope is built with the continuously configurable magnification ratio between 0.8×–11.5×. At the same time, the miniature microscope can capture high-quality microscopic images with a maximum resolution of up to 575 lp/mm and a maximum field of view (FOV) of up to 7213 × 5443 um. Furthermore, by moving the tube lens module of the microscope out of the cell phone body, the built miniature microscope is as compact as a <20 mm side length cube, improving operational experience profoundly. The proposed scheme marks a big step forward in terms of the imaging performance and user operational convenience for cell phone microscopes.

2019 ◽  
Author(s):  
Jin-Sun Jeong ◽  
Nan-Sim Pang ◽  
Yiseul Choi ◽  
Kyeong-Mee Park ◽  
Taekbin Kim ◽  
...  

BACKGROUND High-quality photos are critical for the remote diagnosis of dental trauma and thus are beneficial to the prognosis. The quality of the images obtained using a cell phone depends on the level of dental and photography knowledge of the person who is taking the photos. OBJECTIVE This study aimed to determine the efficacy of photography education in improving images used for the remote diagnosis of dental trauma. METHODS The subjects comprised 30 laypeople and 30 dentists who were randomly assigned to 15 subgroups with 2 subjects in each. Each subject was asked to take photos of their own anterior teeth and those of their partner on the assumption that an accident occurred using both an iPhone 4s and iPhone 6. Education about how to take an appropriate photo of the anterior teeth for teleconsultation purposes was then provided, after which photos were taken again. Photos were assessed by a dentist for their usefulness in diagnosis. RESULTS This study analyzed 965 photos: 441 taken by laypeople and 524 taken by dentists. Photos taken after providing education had significantly higher scores for all assessment items than those taken before education (<i>P</i>&lt;.05). The scores were also significantly higher for photos taken using the rear camera than those taken using the front camera (<i>P</i>&lt;.02). The iPhone 6 did not have overwhelming advantages. The photos taken by dentists had significantly higher scores than those taken by laypeople for most of the evaluated items. CONCLUSIONS Both laypeople and dentists might find photography education useful for when they are taking photos to be used in teleconsultations. The type of cell phone does not significantly affect the usefulness of such photos.


2016 ◽  
Vol 71 (5) ◽  
pp. 988-995 ◽  
Author(s):  
Patrick D. Barnett ◽  
S. Michael Angel

A spatial heterodyne Raman spectrometer (SHRS) with millimeter-sized optics has been coupled with a standard cell phone camera as a detector for Raman measurements. The SHRS is a dispersive-based interferometer with no moving parts and the design is amenable to miniaturization while maintaining high resolution and large spectral range. In this paper, a SHRS with 2.5 mm diffraction gratings has been developed with 17.5 cm−1 theoretical spectral resolution. The footprint of the SHRS is orders of magnitude smaller than the footprint of charge-coupled device (CCD) detectors typically employed in Raman spectrometers, thus smaller detectors are being explored to shrink the entire spectrometer package. This paper describes the performance of a SHRS with 2.5 mm wide diffraction gratings and a cell phone camera detector, using only the cell phone’s built-in optics to couple the output of the SHRS to the sensor. Raman spectra of a variety of samples measured with the cell phone are compared to measurements made using the same miniature SHRS with high-quality imaging optics and a high-quality, scientific-grade, thermoelectrically cooled CCD.


10.2196/15152 ◽  
2020 ◽  
Vol 8 (3) ◽  
pp. e15152
Author(s):  
Jin-Sun Jeong ◽  
Nan-Sim Pang ◽  
Yiseul Choi ◽  
Kyeong-Mee Park ◽  
Taekbin Kim ◽  
...  

Background High-quality photos are critical for the remote diagnosis of dental trauma and thus are beneficial to the prognosis. The quality of the images obtained using a cell phone depends on the level of dental and photography knowledge of the person who is taking the photos. Objective This study aimed to determine the efficacy of photography education in improving images used for the remote diagnosis of dental trauma. Methods The subjects comprised 30 laypeople and 30 dentists who were randomly assigned to 15 subgroups with 2 subjects in each. Each subject was asked to take photos of their own anterior teeth and those of their partner on the assumption that an accident occurred using both an iPhone 4s and iPhone 6. Education about how to take an appropriate photo of the anterior teeth for teleconsultation purposes was then provided, after which photos were taken again. Photos were assessed by a dentist for their usefulness in diagnosis. Results This study analyzed 965 photos: 441 taken by laypeople and 524 taken by dentists. Photos taken after providing education had significantly higher scores for all assessment items than those taken before education (P<.05). The scores were also significantly higher for photos taken using the rear camera than those taken using the front camera (P<.02). The iPhone 6 did not have overwhelming advantages. The photos taken by dentists had significantly higher scores than those taken by laypeople for most of the evaluated items. Conclusions Both laypeople and dentists might find photography education useful for when they are taking photos to be used in teleconsultations. The type of cell phone does not significantly affect the usefulness of such photos.


Author(s):  
A. V. Crewe ◽  
J. Wall ◽  
L. M. Welter

A scanning microscope using a field emission source has been described elsewhere. This microscope has now been improved by replacing the single magnetic lens with a high quality lens of the type described by Ruska. This lens has a focal length of 1 mm and a spherical aberration coefficient of 0.5 mm. The final spot size, and therefore the microscope resolution, is limited by the aberration of this lens to about 6 Å.The lens has been constructed very carefully, maintaining a tolerance of + 1 μ on all critical surfaces. The gun is prealigned on the lens to form a compact unit. The only mechanical adjustments are those which control the specimen and the tip positions. The microscope can be used in two modes. With the lens off and the gun focused on the specimen, the resolution is 250 Å over an undistorted field of view of 2 mm. With the lens on,the resolution is 20 Å or better over a field of view of 40 microns. The magnification can be accurately varied by attenuating the raster current.


2011 ◽  
Vol 20 (1) ◽  
pp. 34-37 ◽  
Author(s):  
David Chapple

Abstract Over the past 20 years, there have been many advances in the computer industry as well as in augmentative and alternative communication (AAC) devices. Computers are becoming more compact and have multiple purposes, such as the iPhone, which is a cell phone, mp3 player, and an Internet browser. AAC devices also have evolved to become multi-purpose devices; the most sophisticated devices have functionality similar to the iPhone and iPod. Recently, the idea of having the iPhone and iPad as a communication device was initiated with the development of language applications specifically for this format. It might be true that this idea could become the future of AAC devices; however, there are major access issues to overcome before the idea is a reality. This article will chronicle advancements in AAC devices, specifically on access methods, throughout the years, towards the transition to handheld devices. The newest technologies hold much promise with both features and affordability factors being highly attractive. Yet, these technologies must be made to incorporate alternate access if they are to meet their fullest potential as AAC tools.


Author(s):  
Patrick Siebert ◽  
Mustapha Mouloua ◽  
Kendra Burns ◽  
Jennifer Marino ◽  
Lora Scagliola ◽  
...  

This study used both cellular phones and analogue radio to measure driver distraction and workload in a low fidelity driving simulator. Thirty-four participants performed a simulated driving task while using either a cell phone or a radio in conjunction with a secondary task assessing their spare attentional capacity. The results showed that more lane deviations were made during the cell phone and radio tuning use than both of the pre-allocation and Post-allocation phases. The secondary task errors were also higher during both the cell phone and radio tuning allocation phase than the pre-allocation and post-allocation phases. These findings indicate the greater workload load levels associated with the use of telemetric devices. These findings have major implications for driver safety and telemetric systems design.