scholarly journals Cervical Vertebral Maturation Method: Reproducibility and Efficiency of Chronological Age Estimation

2021 ◽  
Vol 11 (7) ◽  
pp. 3160
Author(s):  
Lydia Schoretsaniti ◽  
Anastasia Mitsea ◽  
Kety Karayianni ◽  
Iosif Sifakakis

The aim of this study was to investigate the reproducibility of the Cervical Vertebral Maturation (CVM) method and the potential for chronological age estimation using this method. The sample consisted of 474 lateral cephalometric radiographs, from orthodontic patients aged 6.4–22.4 years. Six raters were trained to the CVM method (Baccetti). All images were assessed twice. Intra- and inter-rater agreements were assessed by Cohen’s weighted kappa and intraclass correlation coefficient, respectively. Analysis of variance was performed to investigate the correlation between cervical maturation stages and chronological age. The age prediction potential of the method was tested by general linear model regression analysis. Intra-rater reliability ranged from 0.857 to 0.931. Intra-rater absolute agreement ranged from 77% to 87% however inter-rater absolute agreement was lower than 50%. Inter-rater reliability was higher than 0.9. The 3rd Cervical Maturation Stage (CS3) showed the lowest reproducibility. The mean age differences among the 6 CS stages were statistically significant and increased as the CS increased. CS and gender could roughly explain the 60% (adjusted R2 = 0.61) of the age variance of the sample. This CVM method proved able to show high reliability; however, it cannot predict accurately the pubertal growth spurt. A direct correlation was found between cervical stages and chronological age. This method provides a broad estimation of chronological age.

PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9687
Author(s):  
Vanina Costa ◽  
Óscar Ramírez ◽  
Abraham Otero ◽  
Daniel Muñoz-García ◽  
Sandra Uribarri ◽  
...  

Background Elbow and wrist chronic conditions are very common among musculoskeletal problems. These painful conditions affect muscle function, which ultimately leads to a decrease in the joint’s Range Of Motion (ROM). Due to their portability and ease of use, goniometers are still the most widespread tool for measuring ROM. Inertial sensors are emerging as a digital, low-cost and accurate alternative. However, whereas inertial sensors are commonly used in research studies, due to the lack of information about their validity and reliability, they are not widely used in the clinical practice. The goal of this study is to assess the validity and intra-inter-rater reliability of inertial sensors for measuring active ROM of the elbow and wrist. Materials and Methods Measures were taken simultaneously with inertial sensors (Werium™ system) and a universal goniometer. The process involved two physiotherapists (“rater A” and “rater B”) and an engineer responsible for the technical issues. Twenty-nine asymptomatic subjects were assessed individually in two sessions separated by 48 h. The procedure was repeated by rater A followed by rater B with random order. Three repetitions of each active movement (elbow flexion, pronation, and supination; and wrist flexion, extension, radial deviation and ulnar deviation) were executed starting from the neutral position until the ROM end-feel; that is, until ROM reached its maximum due to be stopped by the anatomy. The coefficient of determination (r2) and the Intraclass Correlation Coefficient (ICC) were calculated to assess the intra-rater and inter-rater reliability. The Standard Error of the Measurement and the Minimum Detectable Change and a Bland–Altman plots were also calculated. Results Similar ROM values when measured with both instruments were obtained for the elbow (maximum difference of 3° for all the movements) and wrist (maximum difference of 1° for all the movements). These values were within the normal range when compared to literature studies. The concurrent validity analysis for all the movements yielded ICC values ≥0.78 for the elbow and ≥0.95 for the wrist. Concerning reliability, the ICC values denoted a high reliability of inertial sensors for all the different movements. In the case of the elbow, intra-rater and inter-rater reliability ICC values range from 0.83 to 0.96 and from 0.94 to 0.97, respectively. Intra-rater analysis of the wrist yielded ICC values between 0.81 and 0.93, while the ICC values for the inter-rater analysis range from 0.93 to 0.99. Conclusions Inertial sensors are a valid and reliable tool for measuring elbow and wrist active ROM. Particularly noteworthy is their high inter-rater reliability, often questioned in measurement tools. The lowest reliability is observed in elbow prono-supination, probably due to skin artifacts. Based on these results and their advantages, inertial sensors can be considered a valid assessment tool for wrist and elbow ROM.


2019 ◽  
Vol 32 (1) ◽  
pp. 69-74
Author(s):  
Seul Gi Koo ◽  
Hae Yean Park ◽  
Jongbae Kim ◽  
Areum Han

Objective The purpose of this study is to introduce a standardised assessment tool by verifying the reliability of the translated Korean version of the Feeding Abilities Assessment (K-FAA), which was developed to suit Korean culture. Methods The research subjects were 65 patients with dementia living in nursing homes. The K-FAA was completed by verifying the suitability of translation and reverse translation. The validity of the K-FAA was established through content validity, while its reliability was analysed based on internal consistency reliability for the items, test–retest reliability and inter-rater reliability. Results The content validity index determined, based on the assessment of professors, occupational therapists, and nurses, was more than .70. Cronbach’s α was more than .929, showing good internal consistency. A test–retest reliability of .884 was derived using Pearson’s correlation coefficient (p < .01), and an inter-rater reliability of .800 was derived using the kappa coefficients; intraclass correlation coefficient was .897, which also indicated good reliability. Conclusion The K-FAA was modified to fit the Korean domestic situation, and this assessment had high reliability. Therefore, K-FAA can evaluate the feeding ability of patients with dementia. Future studies should focus on providing evidence-based data to maintain or supplement the feeding ability of patients with dementia in Korea.


2021 ◽  
Vol 39 ◽  
Author(s):  
Juliana Vieira Campos ◽  
Mariana Alves Moreno ◽  
Ricardo de Bastos Silva ◽  
Jessica Neves Quirino da Silva ◽  
Milena Ferreira de Carvalho ◽  
...  

ABSTRACT Objective: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. Methods: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were placed in the supine position, with retroverted pelvis and semiflexed knees. Acrylic markers were positioned on surgical tape in eight predetermined anatomical points. We analyzed 4 variables in lateral view and 11 in anterior view (angular and linear) (ImageJ®), divided into two stages: 1. same frames - three blinded evaluators analyzed frames previously selected by the main researcher (inter-rater analysis 1), reviewing these same frames after 15 days (intra-rater analysis 1); 2. different frames - each evaluator selected the frames from the original video and repeated the protocol (inter-rater analysis 2), with a review after 15 days (intra-rater analysis 2). In stage 2, we tested the reliability of the entire process, from image selection to the analysis of variables. Data agreement and reproducibility were obtained by the intraclass correlation coefficient (ICC). Results: Agreement was high, particularly in angular variables (ICC 0.82 to 0.99). Linear variables ranged between very good and excellent in analysis 1 (same frames: ICC 0.64 to 0.99) and analysis 2 (different frames: ICC 0.44 to 0.89). Conclusions: The present study suggests that the proposed protocol for the thoracoabdominal motion analysis of preterm neonates has high reliability.


2019 ◽  
Vol 9 (2) ◽  
pp. 52-56
Author(s):  
Natasha Patil ◽  
Neha Maheshwari ◽  
Rohit Sharma ◽  
Shashank Soni ◽  
Ashish Kushwah

Introduction: Skeletal maturity indicators are very important indicators when diagnosing and panning the treatment in growing population. Cervical Vertebrae Method (CVM) and Fishman’s Skeletal Maturity Indicators are two commonly used methods for the diagnosis and treatment planning. The aim of the study was to investigate the correlation between cervical vertebral maturation (CVM)and Fishman’s hand-wrist skeletal maturity indicator and chronological age by including subjects within the range of circumpubertal growth spurt in Central India. Materials & Method: One Twenty Five contemporary hand-wrist and lateral cephalometric radiographs from population of Central India were randomly selected and analyzed. All subjects were within the circumpubertal period i.e. female subjects were between 10 and 15 years of age, and the male subjects were between 12 and 17 years of age. The hand-wrist bone analysis was evaluated using the method developed by Fishman whereas cervical vertebra bone analysis was evaluated using the method developed by Baccetti and co-workers. These two methods and chronological age were correlated using the Spearman rank correlation analysis. Result: CVM was significantly correlated with hand-wrist maturation (r=0.8868). However low correlation was found between the CVM and chronological age( r =0.7139) and little correlation was found between the HWM and chronological age ( r =0.6892). Conclusion: CVM is a valid indicator of skeletal growth during the circumpubertal growth period and has a high correlation with the HWM for the Central India population. However chronological age is not suitable to measure skeletal maturity as shown by the low correlations found between the chronological age and both CVM and HWM.


2020 ◽  
Vol 3 (1) ◽  
pp. 34-39
Author(s):  
Jun Hayakawa ◽  
Mitsuhiro Ochi ◽  
Yudai Yano ◽  
Ryutaro Matsugaki ◽  
Yuto Ogata ◽  
...  

Purpose: This study aimed to determine the inter- and intra-rater reliability of and minimal detectable changes (MDCs) at the 95% confidence interval in gait performance tests in patients with chronic hemiplegic stroke who can walk independently. Materials and Methods: Thirty patients with chronic hemiplegic stroke (24 men, 6 women, mean age 62.5 ± 11.6 years) were enrolled. Physical therapists (mean clinical experience: 9.1 ± 9.3 years) performed the timed up and go test (TUG), 10-m walk test (10MWT), and 6-min walk test (6MWT) 1 day apart. Reliability was evaluated using the intraclass correlation coefficient (ICC) and Bland–Altman analysis. Results: The ICC was ≥0.9 for all tests, and no systematic bias was found. MDC at the 95% confidence interval was 1.9 s for the TUG, 0.16 m/s for the 10MWT, and 28.4 m for the 6MWT. Discussion: We demonstrated excellent intra- and inter-rater reliability of all tests. These results suggest that gait performance tests are reliable. Conclusion: These commonly used gait performance tests demonstrated high reliability and can be recommended to evaluate clinically meaningful improvements in patients with chronic hemiplegic stroke who can walk independently.


Author(s):  
Atefeh Siahi Ahangar ◽  
Sahebeh Ghanbari ◽  
Majid Hajibabaei ◽  
Mahnaz Saremi ◽  
Narges Azadi ◽  
...  

Background: Musculoskeletal disorders are one of the most common occupational diseases, and in recent years, several methods have been developed to evaluate risk factors for these types of disorders. Methods: In this cross-sectional study, 40 tasks in small industries including carpentry, turning, welding, loading and unloading, and sewing were recorded with a video camera and in the second stage, the postures were reviewed and evaluated by six raters. In total, forty of the worst and most frequent postures were analyzed by self-raters and then, the same risk levels were determined for the six methods and analyzed with correlation and Kappa agreement coefficient tests using SPSS (version 19), and then they were compared with each other using the Intraclass correlation coefficient (ICC). Results: The results revealed the importance of Kappa Coefficient in which it shows the risk level of different method and specified pair method: OCRA/SI =0.25, OCRA/HAL=0.2, SI/HAL= 0.32, SI/ RULA= 0.33, REBA/OCRA = 0.4, QEC/SI= 0.27, QEC/ RULA= 0.23Inter-rater Reliability of the methods was found as follow:ICCOCRA=0.3, ICCSI= 0.67, ICCHAL= 0.8, ICCRULA= 0.85, ICCREBA=0.8, ICCQEC=0.972.Conclusions: The results showed that there was no complete agreement among the methods. This agreement among methods is evaluated from poor to good (0.2-0.4). The ICC showed high reliability in the methods except in the OCRA method.


Children ◽  
2020 ◽  
Vol 7 (3) ◽  
pp. 16 ◽  
Author(s):  
Milan Lackovic ◽  
Dejan Nikolic ◽  
Dejan Filimonovic ◽  
Ivana Petronic ◽  
Sladjana Mihajlovic ◽  
...  

Our study aimed to analyze the reliability, consistency, and temporal stability of the Alberta Infant Motor Scale (AIMS) in Serbian infants. Additionally, we aimed to present a percentile distribution of AIMS in the tested population. The prospective study included 60 infants that were divided into three age groups: 0–3 months, 4–7 months, and 8–14 months. The Serbian version of AIMS was tested by two raters on two different occasions (test/retest) with a five day period between tests. The observed inter-rater reliability (intraclass correlation coefficient (ICC)) was more than 0.75 for all AIMS scores, except for standing (ICC 0.655 = moderate) in the age group of 4–7 months on retest between raters. The observed intra-rater reliability (ICC) was more than 0.75 for all AIMS scores except standing (ICC 0.655 = moderate) in the age group 4–7 months in test–retest for Rater One, and for sitting (ICC 0.671 = moderate) and standing (ICC 0.725 = moderate) in the age group between 0–3 months on test–retest for Rater Two. The Serbian version of AIMS was shown to have high consistency and high reliability with good to high temporal stability. Thus, it can be used in the evaluation of infants’ motor development in Serbia.


JKCD ◽  
2019 ◽  
Vol 9 (1) ◽  
pp. 9-11
Author(s):  
Sadaf Ambreen

Objectives: To compare Demirjian Dental scoring method with Greulich-Pyle (GP) Skeletal method of age estimation in pubertal children. Materials and Methods: Sample of the study included 267 male healthy subjects of 11-16 years of age group.. Demirjian Scoring system was utilized to evaluate the orthopantomograms to assess their Dental age and the Hand-Wrist radiographs were analyzed to calculate the skeletal age by utilizing GP atlas. Chronological age was obtained from the date of birth of the subject .Both methods were compared with one another and with the chronological age. It was a cross-sectional study and only healthy male subjects without any clinical abnormalities were included in the study. Results: A total of 267 male subjects of 11-16 years of age group were assessed by Demirjian and Greulich Pyle Methods. Both were compared with Chronological Age. Data obtained was statistically analyzed and the Student “t” test was applied in the study population. The mean difference between Chronolgical age and dental age was 0.69years and that of chronological age and skeletal age was 0.87 years. It was observed from dental age assessment that it does not differ much from the skeletal age. Conclusion: It was concluded that Demirjian method of Age Estimation is more precise than Greulich Pyle method of Age Estimation. Furthermore both methods can be used selectively in Medicolegal cases to access bone age which can be easily correlated to chronological age.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Author(s):  
Blanca De-la-Cruz-Torres ◽  
Emmanuel Navarro-Flores ◽  
Daniel López-López ◽  
Carlos Romero-Morales

Background: the aim of this study was to compare the echotexture of patients with soleus muscle injury and age matched controls. Methods: a sample of 62 athletes was recruited at the private clinic and was divided in two group: a healthy group (n = 31) and a soleus pathology group whose athletes had soleus muscle injury, located in the central tendon (n = 31). The muscle thickness (MTh), echointensity (EI) and echovariation (EV) were analyzed. An intra-rater reliability test (Intraclass Correlation Coefficient-ICC) was performed in order to analyze the reliability of the values of the measurements. Results: Sociodemographic variables did not show statistically significant differences (p > 0.05). Ultrasound imaging measurements who reported statistically significant differences were EI (p = 0.001) and standard deviation (SD) (p = 0.001). MTh and EV variables did not show statistically significant differences (p = 0.381 and p = 0.364, respectively). Moreover, reliability values for the MTh (ICC = 0.911), EI (ICC = 0.982), SD (ICC = 0.955) and EV (ICC = 0.963). Based on these results the intra-rater reliability was considered excellent. Conclusion: Athletes with a central tendon injury of soleus muscle showed a lower EI when they were compared to healthy athletes. The echogenicity showed by the quantitative ultrasound imaging measurement may be a more objective parameter for the diagnosis and follow-up the soleus muscle injuries.


Sign in / Sign up

Export Citation Format

Share Document