scholarly journals Estimation of the Abduction/Adduction Movement of the Metacarpophalangeal Joint of the Thumb

2021 ◽  
Vol 11 (7) ◽  
pp. 3158
Author(s):  
Néstor J. Jarque-Bou ◽  
Margarita Vergara ◽  
Joaquín L. Sancho-Bru

Thumb opposition is essential for grasping, and involves the flexion and abduction of the carpometacarpal and metacarpophalangeal joints of the thumb. The high number of degrees of freedom of the thumb in a fairly small space makes the in vivo recording of its kinematics a challenging task. For this reason, along with the very limited independence of the abduction movement of the metacarpophalangeal joint, many devices do not implement sensors to measure such movement, which may lead to important implications in terms of the accuracy of thumb models. The aims of this work are to examine the correlation between thumb joints and to obtain an equation that allows thumb metacarpophalangeal abduction/adduction movement to be estimated from the other joint motions of the thumb, during the commonest grasps used during activities of daily living and in free movement. The correlation analysis shows that metacarpophalangeal abduction/adduction movement can be expressed mainly from carpometacarpal joint movements. The model thus obtained presents a low estimation error (6.29°), with no significant differences between grasps. The results could benefit most fields that do not typically include this joint movement, such as virtual reality, teleoperation, 3D modeling, prostheses, and exoskeletons.

2021 ◽  
pp. 175319342110177
Author(s):  
Daniel B. Herren ◽  
Hajime Ishikawa ◽  
Marco Rizzo ◽  
Mark Ross ◽  
Michael Solomons

This review describes the different possibilities for arthroplasties at the proximal interphalangeal joint, thumb carpometacarpal joint, distal radioulnar joint, metacarpophalangeal joint and the wrist. For each joint, the indication for arthroplasty is explained, the surgical technique with the suitable implant is described and a brief summary of the outcomes reported in the literature is given.


Author(s):  
Xiaoli Zhang ◽  
Carl A. Nelson

The size and limited dexterity of current surgical robotic systems are factors which limit their usefulness. To improve the level of assimilation of surgical robots in minimally invasive surgery (MIS), a compact, lightweight surgical robotic positioning mechanism with four degrees of freedom (DOF) (three rotational DOF and one translation DOF) is proposed in this paper. This spatial mechanism based on a bevel-gear wrist is remotely driven with three rotation axes intersecting at a remote rotation center (the MIS entry port). Forward and inverse kinematics are derived, and these are used for optimizing the mechanism structure given workspace requirements. By evaluating different spherical geared configurations with various link angles and pitch angles, an optimal design is achieved which performs surgical tool positioning throughout the desired kinematic workspace while occupying a small space bounded by a hemisphere of radius 13.7 cm. This optimized workspace conservatively accounts for collision avoidance between patient and robot or internally between the robot links. This resultant mechanism is highly compact and yet has the dexterity to cover the extended workspace typically required in telesurgery. It can also be used for tool tracking and skills assessment. Due to the linear nature of the gearing relationships, it may also be well suited for implementing force feedback for telesurgery.


2011 ◽  
Vol 200 (1) ◽  
pp. 47-53 ◽  
Author(s):  
Sabine Scheibe ◽  
Mario M. Dorostkar ◽  
Christian Seebacher ◽  
Rainer Uhl ◽  
Frank Lison ◽  
...  

Author(s):  
Carlo Ferraresi ◽  
Carlo De Benedictis ◽  
Walter Franco ◽  
Daniela Maffiodo ◽  
Alberto Leardini

Author(s):  
Derek Lura ◽  
Rajiv Dubey ◽  
Stephanie L. Carey ◽  
M. Jason Highsmith

The prostheses used by the majority of persons with hand/arm amputations today have a very limited range of motion. Transradial (below the elbow) amputees lose the three degrees of freedom provided by the wrist and forearm. Some myoeletric prostheses currently allow for forearm pronation and supination (rotation about an axis parallel to the forearm) and the operation of a powered prosthetic hand. Older body-powered prostheses, incorporating hooks and other cable driven terminal devices, have even fewer degrees of freedom. In order to perform activities of daily living (ADL), a person with amputation(s) must use a greater than normal range of movement from other body joints to compensate for the loss of movement caused by the amputation. By studying the compensatory motion of prosthetic users we can understand the mechanics of how they adapt to the loss of range of motion in a given limb for select tasks. The purpose of this study is to create a biomechanical model that can predict the compensatory motion using given subject data. The simulation can then be used to select the best prosthesis for a given user, or to design prostheses that are more effective at selected tasks, once enough data has been analyzed. Joint locations necessary to accomplish the task with a given configuration are calculated by the simulation for a set of prostheses and tasks. The simulation contains a set of prosthetic configurations that are represented by parameters that consist of the degrees of freedom provided by the selected prosthesis. The simulation also contains a set of task information that includes joint constraints, and trajectories which the hand or prosthesis follows to perform the task. The simulation allows for movement in the wrist and forearm, which is dependent on the prosthetic configuration, elbow flexion, three degrees of rotation at the shoulder joint, movement of the shoulder joint about the sternoclavicular joint, and translation and rotation of the torso. All joints have definable restrictions determined by the prosthesis, and task.


2014 ◽  
Vol 13 (1) ◽  
pp. 167 ◽  
Author(s):  
Evgenij Bobrowitsch ◽  
Andrea Lorenz ◽  
Nikolaus Wülker ◽  
Christian Walter

2014 ◽  
Vol 2014 (0) ◽  
pp. _J0210205--_J0210205-
Author(s):  
Yuto KASUGA ◽  
Kiyoko KAZAMA ◽  
Makoto SAKAMOTO ◽  
Koichi KOBAYASHI

2020 ◽  
Author(s):  
Heiko Stark ◽  
Martin S. Fischer ◽  
Alexander Hunt ◽  
Fletcher Young ◽  
Roger Quinn ◽  
...  

AbstractDogs are an interesting object of investigation because of the wide range of body size, body mass, and physique. In the last several years, the number of clinical and biomechanical studies on dog locomotion has increased. However, the relationship between body structure and joint load during locomotion, as well as between joint load and degenerative diseases of the locomotor system (e.g. dysplasia), are not sufficiently understood. In vivo measurements/records of joint forces and loads or deep/small muscles are complex, invasive, and sometimes ethically questionable. The use of detailed musculoskeletal models may help in filling that knowledge gap. We describe here the methods we used to create a detailed musculoskeletal model with 84 degrees of freedom and 134 muscles. Our model has three key-features: Three-dimensionality, scalability, and modularity. We tested the validity of the model by identifying forelimb muscle synergies of a beagle at walk. We used inverse dynamics and static optimization to estimate muscle activations based on experimental data. We identified three muscle synergy groups by using hierarchical clustering. Predicted activation patterns exhibited good agreement with experimental data for most of the forelimb muscles. We expect that our model will speed up the analysis of how body size, physique, agility, and disease influence joint neuronal control and loading in dog locomotion.


2011 ◽  
Vol 133 (5) ◽  
Author(s):  
Lyle T. Jackson ◽  
Patrick M. Aubin ◽  
Matthew S. Cowley ◽  
Bruce J. Sangeorzan ◽  
William R. Ledoux

The symptomatic flatfoot deformity (pes planus with peri-talar subluxation) can be a debilitating condition. Cadaveric flatfoot models have been employed to study the etiology of the deformity, as well as invasive and noninvasive surgical treatment strategies, by evaluating bone positions. Prior cadaveric flatfoot simulators, however, have not leveraged industrial robotic technologies, which provide several advantages as compared with the previously developed custom fabricated devices. Utilizing a robotic device allows the researcher to experimentally evaluate the flatfoot model at many static instants in the gait cycle, compared with most studies, which model only one to a maximum of three instances. Furthermore, the cadaveric tibia can be statically positioned with more degrees of freedom and with a greater accuracy, and then a custom device typically allows. We created a six degree of freedom robotic cadaveric simulator and used it with a flatfoot model to quantify static bone positions at ten discrete instants over the stance phase of gait. In vivo tibial gait kinematics and ground reaction forces were averaged from ten flatfoot subjects. A fresh frozen cadaveric lower limb was dissected and mounted in the robotic gait simulator (RGS). Biomechanically realistic extrinsic tendon forces, tibial kinematics, and vertical ground reaction forces were applied to the limb. In vitro bone angular position of the tibia, calcaneus, talus, navicular, medial cuneiform, and first metatarsal were recorded between 0% and 90% of stance phase at discrete 10% increments using a retroreflective six-camera motion analysis system. The foot was conditioned flat through ligament attenuation and axial cyclic loading. Post-flat testing was repeated to study the pes planus deformity. Comparison was then made between the pre-flat and post-flat conditions. The RGS was able to recreate ten gait positions of the in vivo pes planus subjects in static increments. The in vitro vertical ground reaction force was within ±1 standard deviation (SD) of the in vivo data. The in vitro sagittal, coronal, and transverse plane tibial kinematics were almost entirely within ±1 SD of the in vivo data. The model showed changes consistent with the flexible flatfoot pathology including the collapse of the medial arch and abduction of the forefoot, despite unexpected hindfoot inversion. Unlike previous static flatfoot models that use simplified tibial degrees of freedom to characterize only the midpoint of the stance phase or at most three gait positions, our simulator represented the stance phase of gait with ten discrete positions and with six tibial degrees of freedom. This system has the potential to replicate foot function to permit both noninvasive and surgical treatment evaluations throughout the stance phase of gait, perhaps eliciting unknown advantages or disadvantages of these treatments at other points in the gait cycle.


Author(s):  
Andrea J. Rebmann ◽  
Barry P. Boden ◽  
Frances T. Sheehan

In order to correctly diagnose and treat pathological knee joint mechanics we must be able to non-invasively quantify the 3D in vivo kinematics of this joint. Unfortunately, the majority of clinical diagnoses, for this joint, are based upon static 2D imaging. This is due to the fact that currently there is a scarcity of noninvasive measurement techniques that acquire 3D in vivo data dynamically. Thus, in vivo patellofemoral (PF) kinematic measurements typically compress a 3D time-dependent joint attitude to a static 2D representation. The purpose of this study was to investigate if patellar maltracking is limited to two dimensions, as assumed clinically, or if it is a complete six-degree of freedom problem. To do this, we quantified the 3D patellofemoral and tibiofemoral (TF) kinematics in both healthy individuals and those with suspected patellofemoral maltracking using fast-phase contrast magnetic resonance imaging, a technique developed in our previous work. Our data suggest that variations in kinematics were not confined to the standard axial plane measures (e.g. patellar tilt, patellar subluxation), but variations are exhibited in all six degrees of freedom. Therefore, future clinical diagnoses and interventions along with future research will be most effective if the measures used are broadened to include all six-degrees of freedom.


Sign in / Sign up