scholarly journals Does Adhesive Layer Thickness and Tag Length Influence Short/Long-Term Bond Strength of Universal Adhesive Systems? An In-Vitro Study

2021 ◽  
Vol 11 (6) ◽  
pp. 2635
Author(s):  
Naji Kharouf ◽  
Tarek Ashi ◽  
Ammar Eid ◽  
Levi Maguina ◽  
Jihed Zghal ◽  
...  

(1) Background: This study investigated the effect of the adhesive layer thickness and the length of resin tags on dentin bond strength of five universal adhesives applied in self-etch mode. (2) Methods: One hundred and fifty extracted human third molars were used. Five different universal adhesives were applied in self-etch mode on the dentin surface. Half of the specimens were subjected to an aging procedure for six months. A shear bond strength (SBS) test was performed and the results were statistically analyzed with a t-test and one-way ANOVA test. Scanning electron microscopy (SEM) was executed to measure the adhesive layer thickness and tag depth. (3) Results: No statistical differences were found between the five adhesive systems after a 24 h storage period, regardless of layer thickness and tag depth (p < 0.05). After 6 months of aging in water at 37 °C, Iperbond Max and Scotchbond Universal preserved the bond strength over time (p < 0.05), whilst the SBS of Iperbond Ultra, FuturaBond M+, and Ibond Universal decreased significantly after the aging period. No relation was observed between the adhesive thickness or tags’ length on SBS. (4) Conclusions: Within the limitation of this study, the stability over time of the bond strength of universal adhesives depends on their compositions regardless of the adhesive layer thickness and/or tags’ length.

2017 ◽  
Vol 42 (3) ◽  
pp. 284-296 ◽  
Author(s):  
EC Martini ◽  
SO Parreiras ◽  
MF Gutierrez ◽  
AD Loguercio ◽  
A Reis

SUMMARY Objectives: The aim of this study was to investigate the effect of different protocols of 17% ethylene diamine tetra-acetic acid (EDTA) conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Methods and Materials: Forty bovine teeth with sclerotic dentin and 20 human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, two-minute EDTA conditioning manual application, 30-second EDTA manual application, 30-second EDTA sonic application) and adhesives systems (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bond specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests, respectively. The etching pattern produced on the unground enamel and the sclerotic dentin surfaces under the different protocols and adhesive systems was evaluated under scanning electron microscopy. Results: For enamel, only the main factor adhesive was significant (p&lt;0.0001), with SBU showing the highest μSBS. In sclerotic dentin, the lowest mean was observed for the group without EDTA application and the highest mean in the group with EDTA application with the sonic device for 30 seconds. Regardless of the EDTA protocol, the highest means of μTBS were observed for SBU (p&lt;0.05). Conclusions: EDTA conditioning improves the bonding performance of universal adhesives in the self-etch mode on sclerotic dentin, mainly when applied for 30 seconds with the aid of a sonic device. EDTA pretreatment also improves the retentive etching pattern of enamel, but it does not result in higher enamel bond strength.


2015 ◽  
Vol 40 (3) ◽  
pp. 282-292 ◽  
Author(s):  
MA Muñoz ◽  
I Luque-Martinez ◽  
P Malaquias ◽  
V Hass ◽  
A Reis ◽  
...  

SUMMARY Purpose To evaluate the immediate and 6-month resin-dentin bond strength (μTBS) and nanoleakage (NL) of universal adhesives that contain or do not contain methacryloyloxydecyl dihydrogen phosphate (MDP) and are used in the etch-and-rinse and self-etch strategies. Methods and Materials Forty caries-free extracted third molars were divided into eight groups for μTBS (n=5). The groups were bonded with the Clearfil SE Bond (CSE) and Adper Single Bond 2 (SB) as controls; Peak Universal, self-etch (PkSe) and etch-and rinse (PkEr); Scotchbond Universal Adhesive, self-etch (ScSe) and etch-and-rinse (ScEr); and All Bond Universal, self-etch (AlSe) and etch-and-rinse (AlEr). After composite restorations, specimens were longitudinally sectioned to obtain resin-dentin bonded sticks (0.8 mm2). The μTBS of the specimens was tested immediately (IM) or after 6 months of water storage (6M) at 0.5 mm/min. Some sticks at each storage period were immersed in silver nitrate and photo developed, and the NL was evaluated with scanning electron microscopy. Data were analyzed with two-way repeated-measures analysis of variance and Tukey test (α=0.05). Results At the IM period, PkSe and PkEr showed μTBS similar to the control adhesives (p&gt;0.05) but increased NL pattern and lower μTBS after 6M (p&lt;0.05). ScSe and ScEr showed intermediary μTBS values at the IM period but remained stable after 6 months (p&gt;0.05). AlSe showed the lowest μTBS (p&lt;0.05), but μTBS and NL remained stable after 6M (p&gt;0.05). AlEr showed higher IM μTBS but showed higher degradation after 6M (p&lt;0.05). Conclusions Universal adhesives that contain MDP showed higher and more stable μTBS with reduced NL at the interfaces after 6 months of water storage.


2021 ◽  
Vol 45 (3) ◽  
pp. 186-192
Author(s):  
Min Jin Kim ◽  
Joonhee Kim ◽  
Ji-Soo Song ◽  
Shin Hye Chung ◽  
Hong-Keun Hyun

Objective: To compare the shear bond strength (SBS) after thermocycling of four universal adhesives applied in self-etch mode on dentin and etch-and-rinse mode on enamel. Study design: Flat 144 buccal or lingual dentin and enamel surfaces from 72 non-carious primary molars were prepared. Samples were segregated into 12 groups (n=12): Adper Single Bond 2 etch-and-rinse (SB_T) and Clearfil SE Bond self-etch (SE_S) applied to enamel and dentin served as controls. Scotch Bond Universal Adhesive (SBU), Clearfil S3 Bond Universal Adhesive (SEU), Tetric N-Bond Universal Adhesive (TEN), and All Bond Universal (BIS) were applied in etch-and-rinse mode to enamel and in self-etch mode to dentin. They were thermocycled for 5000 cycles. SBS testing and the evaluation of fracture mode were performed. Results: SB_T showed statistically higher SBS than other adhesive groups using etch-and-rinse mode on enamel. SE_S and BIS had statistically higher SBS than other adhesive groups using self-etch mode on dentin. Mixed failure was the most common failure mode in each group. Conclusion: The universal adhesives did not show higher SBS than SB_T when using etch-and-rinse on enamel. All universal adhesives showed higher SBS than SB_T and had SBS similar to SE_S, except SBU when using self-etch mode on dentin.


Author(s):  
Serdar Akarsu DDS, PhD ◽  
Sultan Aktuğ Karademir DDS

The aim of this study was to evaluate the shear bond strength (SBS) of two universal adhesives (Universal Single Bond and All Bond Universal) and a two-step self-etch adhesive system (Clearfil SE Bond) to dentine at various temperatures. Materials and Methods: One hundred and twenty dentin specimens were divided randomly to 12 groups, according to adhesive systems (Universal Single Bond and All Bond Universal, Clearfil SE Bond)  and temperature  ( 4ºC, 20 ºC, 36ºC, 55ºC) used. Dentin specimens were prepared (n :10, adhesives were applied, and composite cylinders were polymerized. Statistical analysis of the SBS data was performed using Two-way analysis of variance (ANOVA) and Tukey’s Honestly Significant Differences post-hoc test. Results: The Clearfil SE Bond was shown to have higher SBS than the universal adhesives at all temperatures; however, there was no statistically significant difference (P>0.05). In both groups, the lowest SBS values were observed in the samples at 4°C while the highest SBS values were observed in the samples at 55°C. In this case, there was a statistically significant difference (P<0.05). Conclusions: The results suggest that the effectiveness of an adhesive may increase if it is preheated at 36°C or above before use instead of being used immediately after removal from the refrigerator or at room temperature.


2017 ◽  
Vol 18 (1) ◽  
pp. 34-38
Author(s):  
Mojtaba Abdollahi ◽  
Masoumeh Ebrahimi ◽  
Alireza Sarraf Shirazi ◽  
Faraneh Abdolhoseinpour

ABSTRACT Introduction One of the possible mechanisms for the gradual destruction of bond strength in dentin-resin interface, could be due to the demineralized unstable collagen matrix. Use of protease inhibitors, such as tannic acid (TA) could prevent destruction of collagen fibers. The aim of this study was to compare the TA effect on bond strength of etch and rinse and self-etch adhesive systems in the dentin of primary teeth. Materials and methods This in vitro study was done on 40 extracted primary molar teeth. The teeth were sectioned in the mesiodistal direction, and enamel of buccal and lingual surfaces was removed. Samples were randomly divided into four groups: Single bond (SB) + TA, SB, Clearfil SE Bond (CSB) + TA, and CSB. Then, Z250 and Clearfil AP-X composites were cured on the surfaces of SB and CSB groups respectively. After that, all samples were divided into aging and non-aging groups. For 3 months, samples were placed under 1,000 thermal cycles in aging group. Subsequently, the shear bond strengths of all groups were measured by the International testing machine, and failure mode was evaluated by an optical stereomicroscope. Data were analyzed with paired t-test and independent t-test. Results Tannic acid induced a significant reduction in the immediate bond strength of adhesive SB. Meanwhile, TA had no significant effect on shear bond strength of the CSB system. Conclusion Based on our findings, use of TA is not recommended with SB and CSB adhesives on primary teeth. Clinical significance Tannic acid may not be considered in resin restorations of primary teeth. How to cite this article Ebrahimi M, Sarraf Shirazi A, Abdolhoseinpour F, Abdollahi M. Effect of Tannic Acid on Bond Strength of Etch and Rinse and Self-etch Adhesive Systems in Dentin of Primary Teeth. J Contemp Dent Pract 2017;18(1):34-38.


2005 ◽  
Vol 16 (2) ◽  
pp. 107-111 ◽  
Author(s):  
Eduardo Batista Franco ◽  
Lawrence Gonzaga Lopes ◽  
Paulo Henrique Perlatti D'Alpino ◽  
José Carlos Pereira

The purpose of this study was to investigate the effect of pH of different adhesive systems on the polymerization of a chemically cured composite resin (Adaptic - AD), by means of tensile bond strength testing. The adhesive systems tested were: ARM, Prime & Bond 2.1 (PB), Scotchbond Multi Purpose (SMP) and Single Bond (SB). Bond strength at the resin/adhesive system/resin interface was assessed. Five groups (n=5) were formed, according to following configuration: G1: AD/ARM/AD; G2: AD/PB/AD; G3: AD/SMP/AD; G4: AD/SB/AD; G5: AD/AD (no adhesive). A two-mold stainless steel matrix with a cone-shaped opening (1-mm-thick; 4 mm in diameter) was used to obtain resin discs. AD resin was inserted into the first mold, left-self curing and an adhesive layer was applied onto resin surface and light-cured. The second mold was assembled over the first and was filled with the resin. After 10 min, this setting was loaded in tension in a universal testing machine running at a crosshead speed of 0.5 mm/min. Data were submitted to one-way ANOVA and Tukey's test (p<0.05). Bond strength means (kgf) were: G1: 15.23 ± 4.1; G2: 0.00 ± 0.0; G3: 16.96 ± 2.4; G4: 10.08 ± 2.7; G5: 15.44 ± 0.9. There were statistically significant differences (p<0.05) between G2-G1; G2-G3; G2-G4; G4-G1; G4-G3. The systems with the lowest pHs (PB and SB) yielded the lowest bond strength. The findings of this in vitro study demostrates that the pH of adhesive systems influences the polymerization and bond strength of chemically cured resin materials. The low pH simplified adhesive systems showed distinct degrees of incompatibility with the chemically cured resin, when compared to the conventional adhesive systems.


2015 ◽  
Vol 16 (5) ◽  
pp. 335-339 ◽  
Author(s):  
Zeeshan H Ahmad ◽  
Sukumaran Anil ◽  
Alaa El Araby ◽  
Mohammad D Al Amri

ABSTRACT Objective To evaluate the influence of Expasyl® gingival retraction paste on the shear bond strength of self-etch and total-etch adhesive systems. Materials and methods Twenty-four specimens of extracted, caries-free, sound human molars were used in this study. The molars were then cut vertically into halves through the buccal and lingual cusps. Forty-eight specimens were divided into four groups (total-etch, total-etch with Expasyl application, self-etch, self-etch with Expasyl application) and the shear bond strength was tested. Results Expasyl significantly reduced the shear bond strength of the self-etch and total-etch adhesive systems. The self-etch system showed relatively lower performance compared with the total-etch adhesive system. The shear bond strength values of the total-etch adhesive without Expasyl showed the highest bond strength (21.48 ± 2.89), while the self-etching group adhesive treated with Expasyl showed the lowest shear bond strength value (14.89 ± 1.81). Conclusion From the observations of this in vitro study, it can be concluded that the use of Expasyl® gingival retraction system can negatively affect bond strength of adhesives. The total-etch system showed better compatibility to the Expasyl gingival retraction system than the self-etch. How to cite this article Al Baker AMA, El Araby A, Al Amri MD, Sukumaran A. The Impact of Expasyl® Gingival Retraction Paste on the Bond Strength of Self-etch and Total-etch Systems. J Contemp Dent Pract 2015;16(5):335-339.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Sign in / Sign up

Export Citation Format

Share Document