scholarly journals Numerical Design and Laboratory Testing of Encapsulated PCM Panels for PCM-Air Heat Exchangers

2021 ◽  
Vol 11 (2) ◽  
pp. 676
Author(s):  
Thiago Santos ◽  
Luiz C. Wrobel ◽  
Nick Hopper ◽  
Maria Kolokotroni

Heat transfer between encapsulated PCM panels and air plays an important role in PCM-Air heat exchangers. A new design for the encapsulation panel was developed considering practical aspects such as the cost of production and ease of manufacturing, in addition to heat transfer and pressure drop. A number of encapsulated panel surfaces were first investigated via 3D CFD simulations and compared with an existing panel in use by a commercial PCM-Air heat exchanger manufacturer. After validation, 2D CFD simulations were carried out for 32 different geometries to select the most effective design, which was fabricated and tested in the laboratory. Laboratory parameters tested included heat transfer, pressure drop and melting/solidifying. The laboratory results confirmed the improvements of the new panel in comparison with the existing panel and a flat panel. It was found that the proposed design doubled the heat transfer, holds 13.7% more material and the fan can overcome the increased pressure drop.

2021 ◽  
Vol 1 (8 (109)) ◽  
pp. 25-35
Author(s):  
Krisdiyanto Krisdiyanto ◽  
Rahmad Kuncoro Adi ◽  
Sudarisman Sudarisman ◽  
Sinin Bin Hamdan

Heat exchangers are important equipment for the process of placing heat. The most widely used type of heat exchanger is shell and tube. This type is widely used because of its simple and easy design. Design of shell and tube heat exchangers is done by the side or shell variations to get the desired performance. Therefore, research is conducted to study the effect of tube thickness on heat transfer, pressure drop, and stress that occurs in the shell and tube heat exchanger so that the optimal tube thickness is obtained. In this research, the activities carried out are the design of heat exchangers for the production of oxygen with a capacity of 30 tons/day. The standard used in this study is the 9th edition heat exchanger design guidance document compiled by the Tubular Exchanger Manufacturer Association (TEMA). Analysis of the tube thickness effect on heat transfer, pressure drop, and stress was carried out using the SimScale platform. The effect of variations in tube thickness on heat transfer is that the thicker the tube, the lower the heat transfer effectiveness. The highest value of the heat exchanger effectiveness is 0.969 at the tube thickness variation of 0.5 mm. The lowest value of the heat exchanger effectiveness is 0.931 at the tube thickness variation of 1.5 mm. The effect of variations in tube thickness on pressure drop is that the thicker the tube, the higher the pressure drop. The highest value of pressure drop is in the variation in tube thickness of 1.5 mm, 321 Pa. The lowest value of drop pressure is in the variation of 0.5 mm tube thickness, which is 203 Pa. The thickness of the tube also increases the maximum stress on the components of the shell, head, tubesheet, baffle, and saddle, but the value is fluctuating


2018 ◽  
Vol 134 ◽  
pp. 277-291 ◽  
Author(s):  
Mohammad Sepehr ◽  
Seyed Saeed Hashemi ◽  
Mohammad Rahjoo ◽  
Vahid Farhangmehr ◽  
Ashkan Alimoradi

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2069
Author(s):  
Eloy Hontoria ◽  
Alejandro López-Belchí ◽  
Nolberto Munier ◽  
Francisco Vera-García

This paper proposes a methodology aiming at determining the most influent working variables and geometrical parameters over the pressure drop and heat transfer during the condensation process of several refrigerant gases using heat exchangers with pipes mini channels technology. A multi-criteria decision making (MCDM) methodology was used; this MCDM includes a mathematical method called SIMUS (Sequential Interactive Modelling for Urban Systems) that was applied to the results of 2543 tests obtained by using a designed refrigeration rig in which five different refrigerants (R32, R134a, R290, R410A and R1234yf) and two different tube geometries were tested. This methodology allows us to reduce the computational cost compared to the use of neural networks or other model development systems. This research shows six variables out of 39 that better define simultaneously the minimum pressure drop, as well as the maximum heat transfer, saturation pressure fluid entering the condenser being the most important one. Another aim of this research was to highlight a new methodology based on operation research for their application to improve the heat transfer energy efficiency and reduce the CO2 footprint derived of the use of heat exchangers with minichannels.


2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2021 ◽  
Author(s):  
Ronald E. Vieira ◽  
Thiana A. Sedrez ◽  
Siamack A. Shirazi ◽  
Gabriel Silva

Abstract Air-water two-phase flow in circular pipes has been studied by many investigators. However, investigations of multiphase flow in non-circular pipes are still very rare. Triangular pipes have found a number of applications, such as multiphase flow conditioning, erosion mitigation in elbows, compact heat exchanges, solar heat collectors, and electronic cooling systems. This work presents a survey of air-water and air-water-sand flow through circular and triangular pipes. The main objective of this investigation is to study the potential effects of triangular pipe geometry on flow patterns, slug frequency, sand erosion in elbows, and heat transfer in multiphase flow. Firstly, twenty-three experiments were performed for horizontal air-water flow. Detailed videos and slug frequency measurements were collected through circular and triangular clear pipes to identify flow patterns and create a database for these pipe configurations. The effect of corners of the triangular pipe on the liquid distribution was investigated using two different orientations of triangular pipe: apex upward and downward and results of triangular pipes were compared to round tubes. Secondly, ultrasonic wall thickness erosion measurements, paint removal studies, and CFD simulations were carried out to investigate the erosion patterns and magnitudes for liquid-sand and liquid-gas-sand flows in circular and triangular elbows with the same radius of curvature and cross-sectional area. Thirdly, heat transfer rates for liquid flows were also simulated for both circular and triangular pipe cross-sections. Although similar flow patterns are observed in circular and triangular pipe configurations, the orientation of the triangular pipes seems to have an effect on the liquid distribution and slug frequency. For higher liquid rates, slug frequencies are consistently lower in the triangular pipe as compared to the circular pipe. Similarly, the triangular elbow offers better flow behavior as compared to circular elbows when investigated numerically with similar flow rates for erosion patterns for both liquid-sand flow and liquid-gas-sand flows. Experimental and CFD results show that erosion in the circular elbow is about three times larger than in the triangular elbow. Paint studies results validated erosion patterns and their relations with particle impacts. Finally, heat transfer to/from triangular pipes is shown to be more efficient than in circular pipes, making them attractive for compact heat exchangers and heat collectors. This paper represents a novel experimental work and CFD simulations to examine the effects of pipe geometries on multiphase flow in pipes with several practical applications. The present results will help to determine the efficiency of utilizing triangular pipes as compared to circular pipes for several important applications and field operations such as reducing slug frequencies of multiphase flow in pipes, and reducing solid particle erosion of elbows, and also increasing the efficiency of heat exchangers.


Sign in / Sign up

Export Citation Format

Share Document