scholarly journals Clinical Assessment of Dental Implants Placed in Low-Quality Bone Sites Prepared for the Healing Chamber with Osseodensification Concept: A Double-Blind, Randomized Clinical Trial

2021 ◽  
Vol 11 (2) ◽  
pp. 640
Author(s):  
Rafael Coutinho Mello-Machado ◽  
Carlos Fernando de Almeida Barros Mourão ◽  
Kayvon Javid ◽  
Henrique T. Ferreira ◽  
Pietro Montemezzi ◽  
...  

The present study aimed to compare the stability of dental implants placed in low-quality bone prepared for the healing chamber with osseodensification technique and a standard undersized drilling. Sixteen subjects presenting D3 or D4 bone density according to Misch’s classification were randomly distributed to receive dental implants following either osseodensification (G1: n = 29) or standard undersized drilling (G2: n = 26) preparation techniques. Implant insertion torque (IT) and implant stability quotient (ISQ) were measured immediately after implant placement. Implant survival and secondary stability (ISQ) were evaluated after six months. The G1 group showed higher IT (39.0 ± 6.4 Ncm) than G2 (32.0 ± 3.4 Ncm) (p < 0.001). ISQ values were similar (p > 0.05) at the implant insertion (67.1 ± 3.2 and 65.5 ± 2.7 for G1 and G2, respectively). After six months healing, implant survival was equally comparable in both groups (p > 0.05), and ISQ values were higher than those of implant insertion (p < 0.001) but similar (p > 0.05) for both groups (74.0 ± 3.6 and 73.3 ± 3.2 for G1 and G2, respectively). Within the limitations of this study, the present RCT demonstrated that a wider surgical bed prepared by osseodensification instrumentation allowed for the bone healing-chamber concept in low-quality bone without any reduction in implant stability and success rate.

Author(s):  
Noha El-Wassefy ◽  
Lars Sennerby ◽  
Dhoom SIngh Mehta ◽  
Thiago De Santana Santos

“Osseointegration” as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows choice of protocol on a patient to patient basis and provides better case documentation. A successful implant reflects good bone to implant contact and is determined by implant stability both primary and secondary. Implant stability is achieved at two different stages – primary (immediately after implant placement) and secondary (3-4 months after implant placement). Implant stability has been confirmed to affect the process of osseointegration and therefore is essential to understand the methods to measure implant stability and factors influencing. Various methods are developed to assess implant stability which suggests the prognosis of an implant.


2021 ◽  
Vol 15 (4) ◽  
pp. 226-231
Author(s):  
Gulsum Sayin Ozel ◽  
Ozgur Inan ◽  
Asli Secilmis Acar ◽  
Gamze Alniacik Iyidogan ◽  
Dogan Dolanmaz ◽  
...  

Background. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA). Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n=25) or modified (SLActive) surface properties (n=25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time. Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P<0.05). Stability improved each week except in the 4th week in SLActive surface measurements. No significant differences were observed between the groups at 2 and 3 months (P>0.05). Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Mehran Shokri ◽  
Arash Daraeighadikolaei

Background.There is no doubt that the success of the dental implants depends on the stability. The aim of this work was to measure the stability of dental implants prior to loading the implants, using a resonance frequency analysis (RFA) by Osstell mentor device.Methods.Ten healthy and nonsmoker patients over 40 years of age with at least six months of complete or partial edentulous mouth received screw-type dental implants by a 1-stage procedure. RFA measurements were obtained at surgery and 1, 2, 3, 4, 5, 7, and 11 weeks after the implant surgery.Results.Among fifteen implants, the lowest mean stability measurement was for the 4th week after surgery in all bone types. At placement, the mean ISQ obtained with the magnetic device was 77.2 with 95% confidence interval(CI)  =2.49, and then it decreased until the 4th week to 72.13 (95%CI=2.88), and at the last measurement, the mean implant stability significantly (Pvalue<0.05) increased and recorded higher values to 75.6 (95%CI=1.88), at the 11th week.Conclusions.The results may be indicative of a period of time when loading might be disadvantageous prior to the 4th week following implant placement. These suggestions need to be further assessed through future studies.


Author(s):  
João Paulo do Vale Souza ◽  
Clóvis Lamartine de Moraes Melo Neto ◽  
Lucas Tavares Piacenza ◽  
Emily Vivianne Freitas da Silva ◽  
André Luiz de Melo Moreno ◽  
...  

Abstract Objectives This study aimed to assess the relation between the insertion torque and implant stability quotient (ISQ recorded immediately and 6 months after implant placement). Materials and Methods Twenty-five patients over the age of 18 years were selected for this study. One implant was placed per patient after tooth extraction. The implant site needed 15 mm in height and 8 mm in width. All implants had the same size (11.5 × 3.75 mm) and brand (Hexagonal Morse cone, DSP Biomedical). The insertion torque (Ncm) and resonance frequency analysis (ISQ value) (Osstell Mentor) were used to assess the primary stability (on the day of surgery). After 6 months, ISQ value was used to assess the secondary stability of each implant. Statistical Analysis The insertion torque data were correlated with ISQ measurements by using Pearson’s correlation. The significance level was 5%. Results There was a positive correlation between insertion torque and initial ISQ (correlation: 0.457; p = 0.022); however, no correlation was found between insertion torque and final ISQ (p = 0.308). Conclusion The present study demonstrated that there is a positive correlation between the insertion torque and the initial ISQ. Therefore, the higher the insertion torque, the higher the initial ISQ (or vice versa).


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Eik Schiegnitz ◽  
Lena Katharina Müller ◽  
Keyvan Sagheb ◽  
Lisa Theis ◽  
Vahide Cagiran ◽  
...  

Abstract Background and purpose The aim of this clinical study was to investigate the clinical long-term and patient-reported outcome of dental implants in patients with oral cancer. In addition, analysis of the influence of radiation therapy, timing of implant insertion, and augmentation procedures on implant survival was performed. Material and methods This retrospective study investigated the clinical outcome of 711 dental implants in 164 oral cancer patients, inserted by experienced surgeons of the Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Germany. Oral health-related quality of life (OHRQoL) was evaluated. Results Cumulative 5-year and 10-year implant survival rates for all included implants were 87.3% and 80.0%. Implants placed straight after ablative surgery (primary implant placement) and implants placed after completing the oncologic treatment (secondary implant placement) showed a comparable implant survival (92.5% vs. 89.5%; p = 0.635). Irradiation therapy had no significant influence on implant survival of secondary placed implants (p = 0.929). However, regarding implant site (native bone vs. augmented bone) and radiation therapy (non-irradiated bone vs. irradiated bone), implants inserted in irradiated bone that received augmentation procedures showed a statistically significant lower implant survival (p < 0.001). Patients reported a distinct improvement in OHRQoL. Conclusions Promising long-term survival rates of dental implants in patients after treatment of oral cancer were seen. In addition, patients benefit in form of an improved OHRQoL. However, bone augmentation procedures in irradiated bone may result in an impaired implants’ prognosis.


2013 ◽  
Vol 70 (6) ◽  
pp. 586-594 ◽  
Author(s):  
Zoran Vlahovic ◽  
Branko Mihailovic ◽  
Zoran Lazic ◽  
Mileta Golubovic

Background/Aim. Flapless implant surgery has become very important issue during recent years, mostly thanks to computerization of dentistry and software planning of dental implants placements. The aim of this study was to compare flap and flapless surgical techniques for implant placement through radiographic and radiofrequency analyses. Methods. The experiment was made in five domestic pigs. Nine weeks following domestic pigs teeth extraction, implants were placed, on the right side using surgical technique flap, and flapless on the left side. Digital dental Xrays were applied to determine primary dental implant stability quality (ISQ). At certain intervals, not later than three months, the experimental animals were sacrificed, and just before it, control X-rays were applied to measure dental implants stability. Results. Radiographic analysis showed that peri-implant bone resorption in the first 4 weeks following placement implants with flap and flapless surgical techniques was negligible. After the 3 months, mean value of peri-implant bone resorption of the implants placed using flap technique was 1.86 mm, and of those placed using flapless technique was 1.13 mm. In relation to the primary dental implant stability in the first and second week there was an expected decrease in ISQ values, but it was less expressed in the dental implants placed using the flapless technique. In the third week the ISQ values were increased in the dental implants placed by using both techniques, but the increase in flapless implant placement was higher (7.4 ISQ) than in flap implant placement (1.5 ISQ). The upward trend continued in a 4- week period, and after 3 months the dental implant stability values in the implants placed using flap technique were higher than the primary stability for 7.1 ISQ, and in the implants placed using flapless technique were higher comparing to the primary stability for 10.1 ISQ units. Conclusion. Based on the results of radiographic and resonance frequency analyses it can be concluded that the flapless technique in surgical implants placemat, leads to better results.


2017 ◽  
Vol 43 (2) ◽  
pp. 131-138 ◽  
Author(s):  
Yen-Ting Lin ◽  
Adrienne Hong ◽  
Ying-Chin Peng ◽  
Hsiang-Hsi Hong

Clinical decisions regarding the stability and osseointegration of mandibular implants positioned using the bone expansion techniques are conflicting and limited. The objective was to evaluate the stability of implants placed using 2 surgical techniques, selected according to the initial width of the mandibular posterior edentulous ridge, with D3 bone density, during a 12-week period. Fifty-eight implants in 33 patients were evaluated. Thirty-two implants in 24 patients were positioned using the osteotome expansion technique, and 26 fixtures in 17 patients were installed using the conventional drilling technique. The implant stability quotient values were recorded at weeks 0, 1, 2, 3, 4, 6, 8, 10, and 12 postsurgery and evaluated using analysis of variance, independent, and paired t tests. Calibrated according to the stability reading of a 3.3-mm diameter implant, the osteotome expansion group was associated with a lower bone density than the conventional group (64.96 ± 6.25 vs 68.98 ± 5.06, P = .011). The osteotome expansion group achieved a comparable primary stability (ISQb-0, P = .124) and greater increases in secondary stability (ISQb-12, P = .07) than did the conventional technique. A D3 quality ridge with mild horizontal deficiency is expandable by using the osteotome expansion technique. Although the 2 groups presented similar implant stability quotient readings during the study period, the osteotome expansion technique showed significant improvement in secondary stability. The healing patterns for these techniques are therefore inconsistent.


2019 ◽  
Vol 2019 ◽  
pp. 1-4 ◽  
Author(s):  
Antonio Scarano ◽  
Bartolomeo Assenza ◽  
Francesco Inchingolo ◽  
Filiberto Mastrangelo ◽  
Felice Lorusso

Background. The immediate placement of a dental implant could represent an option treatment for the rehabilitation of a postextractive missing tooth socket to replace compromised or untreatable teeth, with the advantage of single-session surgery. In this way, the anatomy of the alveolar bone defect, the preservation of the buccal cortical bone, and the primary stability of the fixture represent the critical factors that consent a precise implant placement. Objective. This case report describes a novel fixture design for postextractive alveolar socket immediate implant. Methods. Two patients (25 and 31 years old) were treated for postextractive dental implant placement to replace both central upper incisor teeth with four implants. The residual bone implant gap was not filled with graft or bone substitute. The restoration was provided following a standard loading protocol by a cement-sealed prosthetic abutment. Results. Clinically, all implants positioned showed an excellent insertion torque. No postoperative complications were reported. At 6 months of healing, the buccal cortical bone and the implant stability were present and well maintained. Conclusion. The evidence of this study allows us to underline the possible advantages of this new fixture design for postextractive implant technique.


2019 ◽  
Vol 8 (5) ◽  
pp. 618 ◽  
Author(s):  
Manuel Fernández-Domínguez ◽  
Victor Ortega-Asensio ◽  
Elena Fuentes Numancia ◽  
Juan Aragoneses ◽  
Horia Barbu ◽  
...  

The aim of this experimental animal study was to assess guided bone regeneration (GBR) and implant stability (ISQ) around two dental implants with different macrogeometries. Forty eight dental implants were placed within six Beagle dogs. The implants were divided into two groups (n = 24 per group): G1 group implants presented semi-conical macrogeometry, a low apical self-tapping portion, and an external hexagonal connection (whereby the cervical portion was bigger than the implant body). G2 group implants presented parallel walls macrogeometry, a strong apical self-tapping portion, and an external hexagonal connection (with the cervical portion parallel to the implant body). Buccal (mouth-related) defects of 2 mm (c2 condition) and 5 mm (c3 condition) were created. For the control condition with no defect (c1), implants were installed at crestal bone level. Eight implants in each group were installed under each condition. The implant stability quotient (ISQ) was measured immediately after implant placement, and on the day of sacrifice (3 months after the implant placement). Histological and histomorphometric procedures and analysis were performed to assess all samples, measuring crestal bone loss (CBL) and bone-to-implant contact (BIC). The data obtained were compared with statistical significance set at p < 0.05. The ISQ results showed a similar evolution between the groups at the two evaluation times, although higher values were found in the G1 group under all conditions. Within the limitations of this animal study, it may be concluded that implant macrogeometry is an important factor influencing guided bone regeneration in buccal defects. Group G1 showed better buccal bone regeneration (CBL) and BIC % at 3 months follow up, also parallel collar design can stimulate bone regeneration more than divergent collar design implants. The apical portion of the implant, with a stronger self-tapping feature, may provide better initial stability, even in the presence of a bone defect in the buccal area.


2019 ◽  
Vol 2019 ◽  
pp. 1-14 ◽  
Author(s):  
Fernanda Faot ◽  
Amália Machado Bielemann ◽  
Alessandra Julie Schuster ◽  
Raissa Micaella Marcello-Machado ◽  
Altair Antoninha Del Bel Cury ◽  
...  

Aim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi2 test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). Results. G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. Conclusion. The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.


Sign in / Sign up

Export Citation Format

Share Document