scholarly journals Smart Heating and Cooling Heat Pump System by Standing Column Well and Cross-Mixing Balancing Well Heat Exchangers

2020 ◽  
Vol 10 (21) ◽  
pp. 7643
Author(s):  
Donggyu Kim ◽  
Myungkwan Lim ◽  
Byeongseok Yu ◽  
Changhee Lee

Standing column well (SCW) geothermal heat exchanger permits a bleeding discharge of less than 20% in the event of a maximum load, which is an inappropriate method of using underground water. In this study, the existing operational method of two adjacent SCW geothermal heat exchangers, each with a single well, was modified. This technology aims to improve the coefficient of performance (COP) of the geothermal system by fundamentally preventing underground water discharge and maintaining a constant temperature of the underground heat exchanger. To curb the bleed water discharge, two balancing wells of cross-mixing methods were employed. The result of the cooling and heating operations with the existing SCW heat exchange system and the balancing well cross-combined heat exchange system showed that the measured COP increases by 23% and 12% during the cooling and heating operations, respectively. When operating with a balanced well cross-mixed heat exchange system, the initial temperature of the underground was constant with a small standard deviation of 0.08–0.12 °C.

Author(s):  
Andrei A. Akhremenkov ◽  
Anatoliy M. Tsirlin ◽  
Vladimir Kazakov

In this paper we consider heat exchange system from point of view of Finite-time thermodynamics. At first time the novel estimate of the minimal entropy production in a general-type heat exchange system with given heat load and fixed heat exchange surface is derived. The corresponding optimal distribution of heat exchange surface and optimal contact temperatures are also obtained. It is proven that if a heat flow is proportional to the difference of contacting flows’ temperatures then dissipation in a multi-flow heat exchanger is minimal only if the ratio of contact temperatures of any two flows at any point inside heat exchanger is the same and the temperatures of all heating flows leaving exchanger are also the same. Our result based on those assumptions: 1. heat transfer law is linear (17); 2. summary exchange surface is given; 3. heat load is given; 4. input tempretures for all flows are given; 5. water equivalents for all flows are given.


2020 ◽  
Vol 12 (24) ◽  
pp. 10445
Author(s):  
Myungkwan Lim ◽  
Kyoungbin Lim ◽  
Changhee Lee

This study proposed a technology to improve the performance characteristics and coefficient of performance (COP) of a geothermal system by fundamentally preventing underground water discharge and maintaining a constant temperature of the underground heat exchanger composed of bleed discharge water that utilizes two balancing wells using cross-mixing methods. Using the standing column well (SCW) and cross-mixing balancing well underground heat exchanger, we compared and analyzed the effective thermal conductivity characteristics and COP characteristics during heating and cooling modes. Consequently, the cross-mixing balancing well underground heat exchanger exhibited more effective thermal conductivity than the SCW underground heat exchanger, with a high COP. Therefore, suggesting the performance was improved using groundwater flow rather than SCW. The comparison and analysis results of the effective heat map characteristics using the results of the SCW and balancing well system showed that the heating operation for the SCW underground heat exchanger had better thermal conductivity characteristics than the cooling operation. In addition, regarding a balancing well underground heat exchanger, the cooling operation exhibited superior thermal conductivity characteristics. Thus, the performance was considered to have improved due to the flow of activated groundwater in the ground and the rapid heat transfer without heat accumulation.


2019 ◽  
Vol 133 ◽  
pp. 1236-1246 ◽  
Author(s):  
Genyr Kappler ◽  
João Batista Dias ◽  
Fernanda Haeberle ◽  
Paulo Roberto Wander ◽  
Carlos Alberto Mendes Moraes ◽  
...  

2019 ◽  
Vol 123 ◽  
pp. 01023 ◽  
Author(s):  
Mykhailo Fyk ◽  
Volodymyr Biletskyi ◽  
Ihor Ryshchenko ◽  
Mohammed Abbood

A review has been conducted of key trends in the development of geometric topology of geothermal heat exchangers. Authors proposed approaches to improving the designs and network structures for heat-transfer media circulation in the bottom-hole space of oil-and-gas reservoirs. Four geometric topologies of geothermal heat exchangers have been analysed: І – ІІ – rectilinear vertical smooth and finned pipelines; ІІІ – IV – a cluster in the form of a set of smooth and finned single-pipe elements, representing a figure of “squirrel wheel” or “meridian sphere” type. It is shown that the most effective technical solution, which ensures the increase in the coefficient of performance (COP) of bore-hole geothermal systems is finning the heat exchanging pipes. For the heat exchangers of І – ІІ type, the calculated increase in COP in comparison with smooth pipes is 40%, and for ІІІ – IV type – 95%. The key parameters influencing the COP of a geothermal heat exchanger are: the radius of fluids draining out during the heat exchange process, the radius of pipelines with circulating heat-transfer medium, the diameter of a cluster heat exchanger, the heat exchange area, the parameters of rocks thermal resistance in the bottom-hole zone of heat-receiving.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1893
Author(s):  
Kwonye Kim ◽  
Jaemin Kim ◽  
Yujin Nam ◽  
Euyjoon Lee ◽  
Eunchul Kang ◽  
...  

A ground source heat pump system is a high-performance technology used for maintaining a stable underground temperature all year-round. However, the high costs for installation, such as for boring and drilling, is a drawback that prevents the system to be rapidly introduced into the market. This study proposes a modular ground heat exchanger (GHX) that can compensate for the disadvantages (such as high-boring/drilling costs) of the conventional vertical GHX. Through a real-scale experiment, a modular GHX was manufactured and buried at a depth of 4 m below ground level; the heat exchange rate and the change in underground temperatures during the GHX operation were tracked and calculated. The average heat exchanges rate was 78.98 W/m and 88.83 W/m during heating and cooling periods, respectively; the underground temperature decreased by 1.2 °C during heat extraction and increased by 4.4 °C during heat emission, with the heat pump (HP) working. The study showed that the modular GHX is a cost-effective alternative to the vertical GHX; further research is needed for application to actual small buildings.


Author(s):  
Xiao Wang ◽  
Lin Fu ◽  
Xiling Zhao ◽  
Hua Liu

In recent years, with the continuous urban expansion, the central heating sources are commonly insufficient in the areas of Northern China. Besides, the increasing heat transfer temperature difference results in more and more exergy loss between the primary heat network and the secondary heat network. This paper introduces a new central heating system which combines the urban heat network with geothermal energy (CHSCHNGE). In this system, the absorption heat exchange unit, which is composed of an absorption heat pump and a water to water heat exchanger, is as alternative to the conventional water to water heat exchanger at the heat exchange station, and the doing work ability of the primary heat network is utilized to drive the absorption heat pump to extract the shallow geothermal energy. In this way, the heat supply ability of the system will be increased with fewer additional energy consumptions. Since the water after driving the absorption heat pump has high temperature, it can continue to heat the supply water coming from the absorption heat pump. As a result, the water of the primary heat network will be stepped cooled and the exergy loss will be reduced. In this study, the performance of the system is simulated based on the mathematical models of the heat source, the absorption heat exchange unit, the ground heat exchanger and the room. The thermodynamic analyses are performed for three systems and the energy efficiency and exergy efficiency are compared. The results show that (a) the COP of the absorption heat exchange unit is 1.25 and the heating capacity of the system increases by 25%, which can effectively reduce the requirements of central heating sources; (b) the PER of the system increases 14.4% more than that of the conventional co-generation central heating system and 54.1% more than that of the ground source heat pump system; (c) the exergy efficiency of the CHSCHNGE is 17.6% higher than that of the conventional co-generation central heating system and 45.6% higher than that of the ground source heat pump system.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1762 ◽  
Author(s):  
Zhe Wang ◽  
Fenghui Han ◽  
Yulong Ji ◽  
Wenhua Li

A marine seawater source heat pump is based on the relatively stable temperature of seawater, and uses it as the system’s cold and heat source to provide the ship with the necessary cold and heat energy. This technology is one of the important solutions to reduce ship energy consumption. Therefore, in this paper, the heat exchanger in the CO2 heat pump system with graphene nano-fluid refrigerant is experimentally studied, and the influence of related factors on its heat transfer enhancement performance is analyzed. First, the paper describes the transformation of the heat pump system experimental bench, the preparation of six different mass concentrations (0~1 wt.%) of graphene nanofluid and its thermophysical properties. Secondly, this paper defines graphene nanofluids as beneficiary fluids, the heat exchanger gains cold fluid heat exergy increase, and the consumption of hot fluid heat is heat exergy decrease. Based on the heat transfer efficiency and exergy efficiency of the heat exchanger, an exergy transfer model was established for a seawater source of tube heat exchanger. Finally, the article carried out a test of enhanced heat transfer of heat exchangers with different concentrations of graphene nanofluid refrigerants under simulated seawater constant temperature conditions and analyzed the test results using energy and an exergy transfer model. The results show that the enhanced heat transfer effect brought by the low concentration (0~0.1 wt.%) of graphene nanofluid is greater than the effect of its viscosity on the performance and has a good exergy transfer effectiveness. When the concentration of graphene nanofluid is too high, the resistance caused by the increase in viscosity will exceed the enhanced heat transfer gain brought by the nanofluid, which results in a significant decrease in the exergy transfer effectiveness.


Sign in / Sign up

Export Citation Format

Share Document