scholarly journals Digital Intraoral Scanners and Alginate Impressions in Reproducing Full Dental Arches: A Comparative 3D Assessment

2020 ◽  
Vol 10 (21) ◽  
pp. 7637
Author(s):  
Kyungmin Clara Lee ◽  
Seong-Joon Park

The purpose of this in vivo study was to compare in vivo full arch intraoral scans obtained using two intraoral scanners and conventional impression. Twenty patients were scanned using TRIOS and iTero scanners, as well as conventional impression. Dental models obtained from alginate impression were scanned with a laboratory desktop scanner. Individual intraoral scan data were compared with corresponding model scans using three-dimensional (3D) surface analysis. The average surface deviations were calculated for quantitative evaluation, and these values were compared between two intraoral scanners using the paired t-test. In the 3D surface analysis, most deviations between intraoral scans and model scans presented on the posterior teeth. The average surface deviations were less than 0.10 ± 0.03 mm. The results of 3D surface analysis indicated that there was 0.10 mm of overall deviation between conventional alginate impressions and in vivo full dental arch intraoral scans. Clinicians should take this into consideration when performing intraoral scanning for full dental arches.

2021 ◽  
Vol 11 (10) ◽  
pp. 4612
Author(s):  
KweonSoo Seo ◽  
Sunjai Kim

Purpose: The aim of this study was to present a new method to analyze the three-dimensional accuracy of complete-arch dental impressions and verify the reliability of the method. Additionally, the accuracies of conventional and intraoral digital impressions were compared using the new method. Methods: A master model was fabricated using 14 milled polyetheretherketone cylinders and a maxillary acrylic model. Each cylinder was positioned and named according to its corresponding tooth position. Twenty-five definitive stone casts were fabricated using conventional impressions of the master model. An intraoral scanner was used to scan the master model 25 times to fabricate 25 digital models. A coordinate measuring machine was used to physically probe each cylinder in the master model and definitive casts. An inspection software was used to probe cylinders of digital models. A three-dimensional part coordinate system was defined and used to compute the centroid coordinate of each cylinder. Intraclass correlation coefficient (ICC) was evaluated to examine the reliability of the new method. Independent two sample t-test was performed to compare the trueness and precision of conventional and intraoral digital impressions (α = 0.05). Results: ICC results showed that, the new method had almost perfect reliability for the measurements of the master model, conventional and digital impression. Conventional impression showed more accurate absolute trueness and precision than intraoral digital impression for most of the tooth positions (p < 0.05). Conclusions: The new method was reliable to analyze the three-dimensional deviation of complete-arch impressions. Conventional impression was still more accurate than digital intraoral impression for complete arches.


Author(s):  
Young-Kyun Kim ◽  
So-Hyun Kim ◽  
Tae-Hyun Choi ◽  
Edwin H. Yen ◽  
Bingshuang Zou ◽  
...  

Abstract Objectives The purpose of this retrospective study was to evaluate the accuracy of intraoral scan (IOS) images in the maxillary and mandibular arches with orthodontic brackets. Material and methods From digital impressions of 140 patients who underwent orthodontic treatment, consecutive IOS images were selected based on standardized inclusion criteria: Two pre-orthodontic IOS images (IOS1 and IOS2) of permanent dentition with fully erupted second molars and IOS images obtained immediately after orthodontic bracket bonding (IOSb). Superimpositions were performed to evaluate the reproducibility of repeated IOS images. Accuracy of IOSb images was analyzed by comparing the average surface errors between IOS1c and IOS2c images, which were IOS images cut based on the same region of the interest as between IOS1 and IOSb images. Results A total of 84 IOS images was analyzed. The average surface errors between IOS1 and IOS2 images were 57 ± 8 μm and 59 ± 14 μm in the maxillary and mandibular arch, respectively, and their reliability was almost perfect. The average errors between IOSb and IOS1c images exhibited an increase, which measured 97 ± 28 μm in the maxillary arch and 95 ± 29 μm in the mandibular arch. These surface deviations between IOSb and IOS1c images were significantly larger in each region as well as entire dentition (P < 0.001) compared to those between IOS1c and IOS2c images. Conclusions The average surface errors of the scans with brackets showed increased values compared with those without brackets. This suggests that orthodontic brackets could affect the trueness of intraoral scan images. Clinical relevance It is necessary for clinicians to consider the effect of brackets on digital impression when using IOS images in orthodontic patients.


2017 ◽  
Vol 10 (03) ◽  
pp. 1750003 ◽  
Author(s):  
Shuang Zhang ◽  
Chengcai Leng ◽  
Hongbo Liu ◽  
Kun Wang ◽  
Jie Tian

Bioluminescence tomography (BLT) is a novel optical molecular imaging technique that advanced the conventional planar bioluminescence imaging (BLI) into a quantifiable three-dimensional (3D) approach in preclinical living animal studies in oncology. In order to solve the inverse problem and reconstruct tumor lesions inside animal body accurately, the prior structural information is commonly obtained from X-ray computed tomography (CT). This strategy requires a complicated hybrid imaging system, extensive post imaging analysis and involvement of ionizing radiation. Moreover, the overall robustness highly depends on the fusion accuracy between the optical and structural information. Here, we present a pure optical bioluminescence tomographic (POBT) system and a novel BLT workflow based on multi-view projection acquisition and 3D surface reconstruction. This method can reconstruct the 3D surface of an imaging subject based on a sparse set of planar white-light and bioluminescent images, so that the prior structural information can be offered for 3D tumor lesion reconstruction without the involvement of CT. The performance of this novel technique was evaluated through the comparison with a conventional dual-modality tomographic (DMT) system and a commercialized optical imaging system (IVIS Spectrum) using three breast cancer xenografts. The results revealed that the new technique offered comparable in vivo tomographic accuracy with the DMT system ([Formula: see text]) in much shorter data analysis time. It also offered significantly better accuracy comparing with the IVIS system ([Formula: see text]) without sacrificing too much time.


2020 ◽  
Vol 9 (3) ◽  
pp. 688 ◽  
Author(s):  
Alexander Schmidt ◽  
Leona Klussmann ◽  
Bernd Wöstmann ◽  
Maximiliane Amelie Schlenz

The aim of this clinical study was to update the available data in the literature regarding the transfer accuracy (trueness/precision) of four current intraoral scanners (IOS) equipped with the latest software versions and to compare these data with conventional impressions (CVI). A metallic reference aid served as a reference dataset. Four digital impressions (Trios3Cart, Trios3Pod, Trios4Pod, and Primescan) and one CVI were investigated in five patients. Scan data were analyzed using three-dimensional analysis software and conventional models using a coordinate measurement machine. The transfer accuracy between the reference aid and the impression methods were compared. Differences with p < 0.05 were considered to be statistically significant. Overall, mean ± standard deviation (SD) transfer accuracy ranged from 24.6 ± 17.7 µm (CVI) to 204.5 ± 182.1 µm (Trios3Pod). The Primescan yielded the lowest deviation for digital impressions (33.8 ± 31.5 µm), followed by Trios4Pod (65.2 ± 52.9 µm), Trios3Cart (84.7 ± 120.3 µm), and Trios3Pod. Within the limitations of this study, current IOS equipped with the latest software versions demonstrated less deviation for short-span distances compared with the conventional impression technique. However, for long-span distances, the conventional impression technique provided the lowest deviation. Overall, currently available IOS systems demonstrated improvement regarding transfer accuracy of full-arch scans in patients.


2017 ◽  
Vol 7 ◽  
pp. 215-218 ◽  
Author(s):  
Shuaib Al Ali ◽  
Pratik Premjani ◽  
Anas H. Al-Mulla ◽  
Donald J. Ferguson

Purpose The purpose of this study was to assess the accuracy of three-dimensional (3D) cone beam computed tomography (CBCT) study casts by comparing with direct measurements taken from plaster study casts. Materials and Methods The dental arches of 30 patient subjects were imaged with a Kodak 9300 3D CBCT devise; Anatomodels were created and in vivo 5 imaging software was used to measure 10 dental arch variables which were compared to measurements of plaster study casts. Results: Three of the 10 variables, i.e., overbite, maxillary intermolar width, and arch length, were found significantly smaller (P < 0.05) using the Anatomodels following nonparametric Wilcoxon signed-rank testing. None of the differences found in the study averaged <0.5 mm. Conclusions 3D CBCT imaging provided clinically acceptable accuracy for dental arch analysis. 3D CBCT imaging tended to underestimate the actual measurement compared to plaster study casts.


Author(s):  
D. Reis ◽  
B. Vian ◽  
J. C. Roland

Wall morphogenesis in higher plants is a problem still open to controversy. Until now the possibility of a transmembrane control and the involvement of microtubules were mostly envisaged. Self-assembly processes have been observed in the case of walls of Chlamydomonas and bacteria. Spontaneous gelling interactions between xanthan and galactomannan from Ceratonia have been analyzed very recently. The present work provides indications that some processes of spontaneous aggregation could occur in higher plants during the formation and expansion of cell wall.Observations were performed on hypocotyl of mung bean (Phaseolus aureus) for which growth characteristics and wall composition have been previously defined.In situ, the walls of actively growing cells (primary walls) show an ordered three-dimensional organization (fig. 1). The wall is typically polylamellate with multifibrillar layers alternately transverse and longitudinal. Between these layers intermediate strata exist in which the orientation of microfibrils progressively rotates. Thus a progressive change in the morphogenetic activity occurs.


Author(s):  
Greg V. Martin ◽  
Ann L. Hubbard

The microtubule (MT) cytoskeleton is necessary for many of the polarized functions of hepatocytes. Among the functions dependent on the MT-based cytoskeleton are polarized secretion of proteins, delivery of endocytosed material to lysosomes, and transcytosis of integral plasma membrane (PM) proteins. Although microtubules have been shown to be crucial to the establishment and maintenance of functional and structural polarization in the hepatocyte, little is known about the architecture of the hepatocyte MT cytoskeleton in vivo, particularly with regard to its relationship to PM domains and membranous organelles. Using an in situ extraction technique that preserves both microtubules and cellular membranes, we have developed a protocol for immunofluorescent co-localization of cytoskeletal elements and integral membrane proteins within 20 µm cryosections of fixed rat liver. Computer-aided 3D reconstruction of multi-spectral confocal microscope images was used to visualize the spatial relationships among the MT cytoskeleton, PM domains and intracellular organelles.


2009 ◽  
Vol 30 (05) ◽  
pp. 432-438 ◽  
Author(s):  
Akira Goto ◽  
Hisao Moritomo ◽  
Tomonobu Itohara ◽  
Tetsu Watanabe ◽  
Kazuomi Sugamoto

Sign in / Sign up

Export Citation Format

Share Document