scholarly journals Influence of Different Heat Treatments on Torsional and Cyclic Fatigue Resistance of Nickel–Titanium Rotary Files: A Comparative Study

2020 ◽  
Vol 10 (16) ◽  
pp. 5604 ◽  
Author(s):  
Gianluca Gambarini ◽  
Andrea Cicconetti ◽  
Dario Di Nardo ◽  
Gabriele Miccoli ◽  
Alessio Zanza ◽  
...  

Protaper Universal (PTU), Protaper Gold (PTG) (Maillefer, Ballaigues, CH), EdgeTaper (ET), and EdgeTaper Platinum (ETP) (Albuquerque, NM, USA) were tested for both torsional and flexural resistance. The aim of the present study was to evaluate the influence of proprietary heat treatment on the metallurgical properties of the aforementioned instruments. Four groups of 30 different instruments (size 20.07) were tested, then divided into two subgroups of 15 instruments—one for the cyclic fatigue test in a curved canal (90°—2 mm radius) at 300 rpm and 2.5 Ncm. The time to fracture (TtF) and fragment length (FL) were recorded. The other subgroup was subjected to the torsional test (300 rpm, 5.5 Ncm). The torque to fracture and TtF were recorded. All the instruments underwent a SEM analysis. The heat-treated instruments showed a significantly higher fatigue resistance than the non-heat-treated instruments (p < 0.05). No significant differences were found in the torsional resistance between the ET and PTU, and the ETP and PTG. However, when comparing all the groups, the heat-treated instruments showed less torsional resistance. The improvement from heat treatment was mainly found in the cyclic fatigue resistance.

Author(s):  
Jader Camilo Pinto ◽  
Fernanda Ferrari Esteves Torres ◽  
Airton Oliveira Santos-Junior ◽  
Marco Antonio Hungaro Duarte ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PDL 35/05, a complementary procedure was performed with PDL 50/.01. Microcomputed tomography (micro-CT) scanning was performed before and after retreatment procedures. The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments (n = 12) was evaluated in a stainless-steel device. Statistical Analysis Data on the volumes of the root canals and the remaining filling materials were submitted to the paired t-test. Cyclic fatigue resistance data was submitted to one-way ANOVA and Tukey’s tests (α = 0.05). Results Use of PDL 50/.01 decreased the remaining filling materials in the apical third (p < 0.05). The root canal volume was similar in the cervical and middle thirds before and after preparation using PDL 50/.01 (p > 0.05). PDL 50/.01 presented the highest cyclic fatigue resistance (p < 0.05). Conclusions Use of the PDL 50/.01 instrument as an additional apical preparation for retreatment of curved root canals improved filling material removal in the apical third, while maintaining the dentin in the cervical and middle thirds. In addition, PDL 50/.01 presented high-flexural resistance.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Suhad Jabbar Hamed Al-Nasrawi ◽  
Zuha Ayad Jaber ◽  
Nibrass Talib Al-Quraine ◽  
Abtesam Imhemed Aljdaimi ◽  
Sattar Jabbar Abdul-Zahra Al-Hmedat ◽  
...  

Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG ( P = 0.209 ). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.


Materials ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 2523 ◽  
Author(s):  
Gianluca Gambarini ◽  
Gabriele Miccoli ◽  
Marco Seracchiani ◽  
Tatyana Khrenova ◽  
Orlando Donfrancesco ◽  
...  

The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel–titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon–Mann–Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments.


2021 ◽  
Author(s):  
Hamed Karkehabadi ◽  
Abbas Farmani ◽  
Zahra Pakseresht ◽  
Faraz Sedaghat ◽  
Saber Yavari Niya

Abstract Objective: This study sought to assess the effect of cryogenic treatment on cyclic fatigue of Neoniti and Reciproc nickel-titanium (NiTi) rotary files. This in vitro, experimental study was performed on 48 Neoniti and Reciproc NiTi rotary files (#25, 6% taper) in two subgroups with and without cryogenic treatment. The files in cryogenic subgroups were stored in liquid nitrogen chamber at -196°C for 24 h. Next, they were placed at room temperature (25°C) to gradually warm up. Stainless steel (SS) blocks were used to standardize the degree of rotation of the files. The SS blocks simulated a root canal with the negative pattern of gutta-percha with 0.08 taper, #25 tip size, and 45° canal curvature. Each endodontic file was rotated in this canal until fracture. The time until fracture was recorded by a digital chronometer. Time to fracture was used to calculate the number of rotations before file fracture as the cyclic fatigue scale. Results: The mean cyclic fatigue resistance of both Neoniti and Reciproc rotary files in cryogenic subgroups was significantly higher than that in non-cryogenic control subgroups (P<0.05). Cryogenic treatment can significantly increase the cyclic fatigue resistance of Neoniti and Reciproc NiTi rotary files.


2018 ◽  
Vol 44 (10) ◽  
pp. 1563-1566 ◽  
Author(s):  
Hussam Alfawaz ◽  
Abdullah Alqedairi ◽  
Hala Alsharekh ◽  
Eman Almuzaini ◽  
Shahd Alzahrani ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Reham Sharroufna ◽  
Mohammed Mashyakhy

Objective. The purpose of this study was to evaluate the effect of repeated autoclave sterilization on the cyclic fatigue resistance of heat-treated NiTi rotary endodontic instruments. Materials and Methods. Three NiTi rotary endodontic instruments (EdgeFile X7, EFX7 0.30/0.4; Vortex Blue, VB 0.30/0.4; and TRUShape, TS 0.30/0.6) were selected. Each group ( n = 24 each) was divided into 2 subgroups ( n = 12 each): sterilized instruments and nonsterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve instruments from each different subgroups were tested for cyclic fatigue resistance, and the number of cycles to failure (NCF) was calculated. Means and standard deviations were calculated for each group, and data were statistically analyzed using the SPSS program ( P < 0.05 ). Results. Sterilized and nonsterilized EFX7 files showed the highest NCF compared with other file subgroups. Comparing the results between sterilized and nonsterilized instruments for each type of files, there was a statistically significant difference ( P < 0.05 ) only between sterilized and nonsterilized EFX7 files (1198 versus 755 NCF). The other instruments did not show significant differences ( P > 0.05 ) in the mean NCF as a result of sterilization cycles (VB, 606 versus 568 NCF; TS, 487 versus 442 NCF). Conclusion. Repeated cycles of autoclave sterilization increased the NCF of the new heat-treated files, with EFX7 showing statistically significant superior results compared with other files tested.


2020 ◽  
Vol 45 (2) ◽  
Author(s):  
Emmanuel João Nogueira Leal Silva ◽  
Mayara Zanon ◽  
Fernanda Hecksher ◽  
Felipe Gonçalves Belladonna ◽  
Rafaela Andrade de Vasconcelos ◽  
...  

2021 ◽  
Vol 24 (4) ◽  
Author(s):  
Marco Seracchiani ◽  
Orlando Donfrancesco ◽  
Michela Relucenti ◽  
Rodolfo Reda ◽  
Alessio Zanza ◽  
...  

Objective: Aim of the present study is to evaluate mechanical properties of a newly developed rotary file, AF Rotary (Fanta Dental, Shanghai, China), and to compare these features with a worldwide spread rotary file, Protaper Gold F2 (PTG F2; Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods: 60 AF Rotary 25.06 and 60 PTG F2 were divided in three groups of 20 files each. A group underwent to cyclic fatigue resistance tests, second group underwent to torsional resistance tests, third group underwent to bending tests. The statistical analysis was performed using t student test with significance level set at 95% (p < 0.05). Results: AF Rotary showed significantly higher torsional resistance and cyclic fatigue resistance (p < 0.05) when compared to the PTG F2. AF Rotary also showed significantly lower bending resistance (p < 0.05) when compared to the PTG F2. Conclusion: Therefore, within the limitations of this study, the results show better performances for AF Rotary compared to PTG F2 regarding the cyclic fatigue test, the torsional test and the bending test. Since the PTG F2 is a commonly used and widely investigated instrument it could be possible to state that the AF Rotary exhibits remarkable in vitro performances.   Keywords AF Rotary; Protaper gold; NiTi rotary instruments; Cyclic fatigue; Torsional resistance.


Sign in / Sign up

Export Citation Format

Share Document