scholarly journals Acoustic Emission Monitoring of the Turin Cathedral Bell Tower: Foreshock and Aftershock Discrimination

2020 ◽  
Vol 10 (11) ◽  
pp. 3931 ◽  
Author(s):  
Amedeo Manuello Bertetto ◽  
Davide Masera ◽  
Alberto Carpinteri

Historical churches, tall ancient masonry buildings, and bell towers are structures subjected to high risks due to their age, elevation, and small base-area-to-height ratio. In this paper, the results of an innovative monitoring technique for structural integrity assessment applied to a historical bell tower are reported. The emblematic case study of the monitoring of the Turin Cathedral bell tower (northwest Italy) is herein presented. First of all, the damage evolution in a portion of the structure localized in the lower levels of the tall masonry building is described by the evaluation of the cumulative number of acoustic emissions (AEs) and by different parameters able to predict the time dependence of the damage development, in addition to the 3D localization of the AE sources. The b-value analysis shows a decreasing trend down to values compatible with the growth of localized micro and macro-cracks in the portion of the structure close to the base of the tower. These results seem to be in good agreement with the static and dynamic analysis performed numerically by an accurate FEM (finite element model). Similar results were also obtained during the application of the AE monitoring to the wooden frame sustaining the bells in the tower cell. Finally, a statistical analysis based on the average values of the b-value are carried out at the scale of the monument and at the seismic regional scale. In particular, according to recent studies, a comparison between the b-value obtained by AE signal analysis and the regional activity is proposed in order to correlate the AE detected on the structure to the seismic activity, discriminating foreshock, and aftershock intervals in the analyzed time series.

2019 ◽  
Vol 817 ◽  
pp. 579-585
Author(s):  
Amedeo Manuello ◽  
Davide Masera ◽  
Alberto Carpinteri

Historical churches, masonry towers and bell towers are structures subjected to high risk, due to their age, elevation and low base area on height ratio. In this work, an innovative monitoring technique for structural integrity assessment of historical buildings is reported. At the same time, the emblematic case study of the Turin Cathedral Bell tower is presented. The damage evolution in the tall masonry structure is described by the evaluation of the cumulative number of AE and by different parameters able to predict the time dependence of damage. In particular, since environmental disturbances have been minimized, and instrumental noises have been filtered out. The b-value analysis shows a downward trend to values compatible with the growth of localized macro-cracks at the base of the tower. These results seem to be in good agreement with the numerical analysis. Extension to longer monitoring periods and, later, investigation of different segments are strongly recommended to assess the stability of the monument.


Author(s):  
Daigo Watanabe ◽  
Kiminobu Hojo

This paper introduces an example of structural integrity evaluation for Light Water Reactor (LWR) against excessive loads on the Design Extension Condition (DEC). In order to assess the design acceptance level of DEC, three acceptance criteria which are the stress basis limit of the current design code, the strain basis limit of the current design code and the strain basis limit by using Load and Resistance Factor Design (LRFD) method were applied. As a result the allowable stress was increased by changing the acceptance criteria from the stress basis limit to the strain basis limit. It is shown that the practical margin of the LWR’s components still keeps even on DEC by introducing an appropriate criterion for integrity assessment and safety factors.


Author(s):  
Sébastien Fouques ◽  
Ole Andreas Hermundstad

The paper is concerned with the launch of free-fall lifeboats (FFL). It proposes a method that complies with the DNV-OS-E406 standard in order to select characteristic launches from Monte Carlo simulations for further structural load assessment with CFD and FEM. Proxy variables derived from kinematic parameters and aiming at predicting pressure load indicators are computed with the VARUNA launch simulator developed by MARINTEK. The statistical distributions of the proxy variables obtained from the Monte Carlo simulations are used to identify critical scenarios, and characteristic launches can then be selected from a chosen probability level. The feasibility of the proposed method is documented in the paper for several types of pressure loads. Existing model test data from various FFL-launch campaigns in calm water and in waves are used to compute the proxy variables as it would be done in the VARUNA simulator. Scatter diagrams showing the correlation with actual measured pressure load indicators are then established to assess the quality of the chosen proxy variables.


Author(s):  
Dominique Moinereau ◽  
Jean-Michel Frund ◽  
Henriette Churier-Bossennec ◽  
Georges Bezdikian ◽  
Alain Martin

A significant extensive Research & Development work is conducted by Electricite´ de France (EDF) related to the structural integrity re-assessment of the French 900 and 1300 MWe reactor pressure vessels in order to increase their lifetime. Within the framework of this programme, numerous developments have been implemented or are in progress related to the methodology to assess flaws during a pressurized thermal shock (PTS) event. The paper contains three aspects: a short description of the specific French approach for RPV PTS assessment, a presentation of recent improvements on thermalhydraulic, materials and mechanical aspects, and finally an overview of the present R&D programme on thermalhydraulic, materials and mechanical aspects. Regarding the last aspect on present R&D programme, several projects in progress will be shortly described. This overview includes the redefinition of some significant thermalhydraulic transients based on some new three-dimensional CFD computations (focused at the present time on small break LOCA transient), the assessment of vessel materials properties, and the improvement of the RPV PTS structural integrity assessment including several themes such as warm pre-stress (WPS), crack arrest, constraint effect ....


Author(s):  
Guomin Ji ◽  
Nabila Berchiche ◽  
Sébastien Fouques ◽  
Thomas Sauder ◽  
Svein-Arne Reinholdtsen

The paper addresses the structural integrity assessment of lifeboat launched from floating production, storage and offloading (FPSO) vessels. The study is based on long-term drop lifeboat simulations accounting for more than 50 years of hindcast data of metocean conditions and corresponding FPSO motions. Selection of the load cases and strength analyses with high computational time is a challenge. The load cases analyzed are those corresponding to the 99th percentile of long term distribution of indicators for large slamming loads (CARXZ) or large submergence (Imaxsub). For six selected cases, the time-varying pressure distribution on the lifeboat hull during and after water impact is calculated by CFD simulations using StarCCM+. The finite element model (FEM) of the composite structure of the lifeboat is modelled by ABAQUS. Quasi-static finite element (FE) analyses are performed for the selected load cases. The structural integrity is assessed by the maximum stress and Tsai-Wu failure measure. In the present study, the load and resistance factors are combined and applied to the response. A sensitivity study is performed to investigate the non-linear load/response effects when the load factor is applied to the load. In addition, dynamic analysis is performed with the time-varying pressure distribution for selected case and the dynamic effect is investigated.


Sign in / Sign up

Export Citation Format

Share Document