scholarly journals Shading on Photovoltaic Collectors on Rooftops

2020 ◽  
Vol 10 (8) ◽  
pp. 2977
Author(s):  
Avi Aronescu ◽  
Joseph Appelbaum

Rooftop photovoltaic (PV) systems in urban environments play an important role in solar electric energy generation. Shading on PV collectors, by self-shading, walls and fences on rooftops, affect negatively the output energy of the PV systems. Increasing the distance between the collector rows, and between the walls and fences near to the collectors, may minimize the shading losses. Practically, this option is usually limited, especially on rooftops. Rooftops may be of different types: horizontal, inclined, and saw-tooth, and may have obscuring structures like walls and fences. The distance between the shading objects and the PV collector rows determine the loss of energy due to shading. The study provides the PV system designer with mathematical expressions for distances from obscuring objects for the deployment of PV systems on rooftops. The optimal inclination and azimuths angles of a PV system on a triangular sloped rooftop are also illustrated.

Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3222 ◽  
Author(s):  
Antans Sauhats ◽  
Laila Zemite ◽  
Lubov Petrichenko ◽  
Igor Moshkin ◽  
Aivo Jasevics

This article analyses the influence of supporting scheme variants on the profitability of a projected investment of residential photovoltaic systems. The focus of the paper lies in evaluating the feasibility for the power system of solar power generation technologies to achieve a balance between energy generation and support costs in a more efficient way. The case study is based on a year-long time series of examples with an hourly resolution of electricity prices from the Nord Pool power market, in addition to the power demand and solar generation of Latvian prosumers. Electric energy generation and the consumption of big data from more than 100 clients were collected. Based on these data, we predict the processes for the next 25 years, and we estimate economic indicators using a detailed description of the net metering billing system and the Monte-Carlo method. A recommendation to change the current net system to a superior one, taking into account the market cost of energy, concludes the paper.


Buildings ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 192
Author(s):  
Zainab Usman ◽  
Joseph Tah ◽  
Henry Abanda ◽  
Charles Nche

Climate change and global warming have triggered a global increase in the use of renewable energy for various purposes. In recent years, the photovoltaic (PV)-system has become one of the most popular renewable energy technologies that captures solar energy for different applications. Despite its popularity, its adoption is still facing enormous challenges, especially in developing countries. Experience from research and practice has revealed that installed PV-systems significantly underperform. This has been one of the major barriers to PV-system adoption, yet it has received very little attention. The poor performance of installed PV-systems means they do not generate the required electric energy output they have been designed to produce. Performance assessment parameters such as performance yields and performance ratio (PR) help to provide mathematical accounts of the expected energy output of PV-systems. Many reasons have been advanced for the disparity in the performance of PV-systems. This study aims to analyze the factors that affect the performance of installed PV-systems, such as geographical location, solar irradiance, dust, and shading. Other factors such as multiplicity of PV-system components in the market and the complexity of the permutations of these components, their types, efficiencies, and their different performance indicators are poorly understood, thus making it difficult to optimize the efficiency of the system as a whole. Furthermore, mathematical computations are presented to prove that the different design methods often used for the design of PV-systems lead to results with significant differences due to different assumptions often made early on. The methods for the design of PV-systems are critically appraised. There is a paucity of literature about the different methods of designing PV-systems, their disparities, and the outcomes of each method. The rationale behind this review is to analyze the variations in designs and offer far-reaching recommendations for future studies so that researchers can come up with more standardized design approaches.


Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 416
Author(s):  
Marko Ikić ◽  
Jovan Mikulović

Aware of the fact that the installed PV capacity and its power production rapidly increased in the last decade, with the huge impact that has been done to the power system, the distortion effects for grid-connected PV systems with reference to different types of electric power quantities will be presented in this article. The impact of the frequent fluctuation of solar irradiance on the behavior of the grid-connected PV system, due to cloud movements and resulting shadows and in terms of power quality and the evaluation of power components, is the topic of analysis in this research. Besides the simulation results of certain study cases, an experimental evaluation of electric power quantities on an actual PV system in real weather conditions was also performed. The experimental setup, formed through the combination of a PC and multifunctional I/O board with an appropriate software solution, was established and used for obtaining the target results. The methodology used for the evaluation of electric power quantities relied on the current physical components (CPC) theory for power definition. The experimental results were obtained for three different cases, namely, the low, medium, and high solar irradiance cases. On the basis of these results, the conclusions about distortion effects are given.


2019 ◽  
Vol 100 ◽  
pp. 00030
Author(s):  
Magdalena Jurasz ◽  
Jerzy Mikulik

The analysis presented in this paper focuses on the energetic aspects of the use of photovoltaic (PV) systems in office buildings. Energy generation from PV system has been simulated on an hourly time scale and compared with the energy demand of two office buildings located in Krakow (southern Poland). The buildings’ annual load exceeded 1 GWh in both cases. The analysis dealt with estimating how much energy generated by a PV system can be utilized on-site (self-consumption) and how big the energy surpluses will be (energy generation greater than demand). Capacities of PV systems ranging from 0.1 to 1.0 MW have been considered. Also, the impact of PV generation on the residual load parameters and changes in the maximal monthly and hourly energy demand were investigated. The results show that although the building energy demand is similar (in terms of annual volume of energy consumed) the potential of PV systems to cover it is different. The 100-kW PV system can reduce the observed hourly peak energy demand by 1% in December but by over 30% in June (respectively, from 171 kWh to 169 kWh, and from 333 kWh to 255 kWh). Considering the annual patterns of the office buildings’ energy demand and PV generation (both have their respective peaks in summer), the application of a PV system changes the office building energy demand pattern significantly from the perspective of the power system operator. After installing 500 kW PV in an office building consuming 1 GWh annually, the months with highest demand are no longer in summer but in winter.


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3271 ◽  
Author(s):  
Milad Zeraatpisheh ◽  
Reza Arababadi ◽  
Mohsen Saffari Pour

It is well known that the use of photovoltaic (PV) systems helps to preserve the environment, produce lower levels of greenhouse gases (GHGs), and reduce global warming, however, whether it is economically profitable for customers or not is highly debatable. This paper aims to address this issue. To be comprehensive, three different types of buildings are considered as case studies. Then, these three buildings are modeled in EnergyPlus to determine the rate of energy consumption. Afterward, comparisons of various solar system sizes based on economic parameters such as the internal rate of return, the net present value, payback period and profitability indexing for various-sized PV systems are carried out. The results show that by the demand charge tariffs, using PV systems has no economic justification. It has been shown that even with neglecting further costs of the PV system like maintenance, by demand charge tariffs, it is not economically beneficial for customers to use the PV systems. Profitability index of all three buildings with various PV power systems is between 0.2 to 0.8, which are by no means is desirable. Moreover, it was found that bigger solar systems are less cost-effective in the presence of demand charges.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3850
Author(s):  
Saeed Swaid ◽  
Joseph Appelbaum ◽  
Avi Aronescu

With the increase in PV system installations, the available free land and rooftops for these systems may become scarcer, and therefore sloped fields facing the north may be utilized for that purpose. In deployments of PV collectors in multiple rows, either on horizontal or sloped planes, the second and subsequent rows are subject to two effects: shading and masking. Both effects reduce the electric energy generated by the PV systems. Multiple rows of collectors are deployed on horizontal planes and on sloped planes facing south, and literature on the topic has been published. No literature deals analytically with deployments of PV fields on north-facing slopes in the northern hemisphere, to the best of our knowledge. The present study develops explicit analytical expressions for the shadow height and length cast on a collector row by a row in front in multiple-row PV systems installed on slopes facing north. In addition, analytical expressions are developed for row spacing and sky view factors, altogether leading consequently to the determination of shading and masking losses. Having the developed expressions, a comparison was made between PV deployments on north-facing sloped planes to PV deployments on horizontal and south-facing slopes regarding shading and masking losses. The main finding is that the percentage of masking losses (diffuse radiation) may exceed the percentage of shading losses (beam radiation) in PV fields. At the local site 32∘ N, collector inclination angle β=25∘ and sloped-plane ε=10∘, for example, the percentage of masking losses for a horizontal plane is 6.90%; for a sloped plane facing south, the losses are 5.39%, and for a sloped plane facing north, the losses are 6.86%. In comparison to the masking losses, the percentage of shading losses for the horizontal plane is 0.83%; for the sloped plane facing south, the losses are 0.42%, and for the sloped plane facing north, the losses are 1.37%.


2019 ◽  
Vol 8 (1) ◽  
pp. 34-52 ◽  
Author(s):  
M. Asif ◽  
Mohammad A. Hassanain ◽  
Kh Md Nahiduzzaman ◽  
Haitham Sawalha

Purpose The Kingdom of Saudi Arabia (KSA) is facing a rapid growth in energy demand mainly because of factors like burgeoning population, economic growth, modernization and infrastructure development. It is estimated that between 2000 and 2017 the power consumption has increased from 120 to 315 TWh. The building sector has an important role in this respect as it accounts for around 80 percent of the total electricity consumption. The situation is imposing significant energy, environmental and economic challenges for the country. To tackle these problems and curtail its dependence on oil-based energy infrastructure, KSA is aiming to develop 9.5 GW of renewable energy projects by 2030. The campus of the King Fahd University of Petroleum and Minerals (KFUPM) has been considered as a case study. In the wake of recently announced net-metering policy, the purpose of this paper is to investigate the prospects of rooftop application of PV in buildings. ArcGIS and PVsyst software have been used to determine the rooftop area and undertake PV system modeling respectively. Performance of PV system has been investigated for both horizontal and tilted installations. The study also investigates the economic feasibility of the PV application with the help of various economic parameters such as benefit cost ratio, simple payback period (SPP) and equity payback periods. An environmental analysis has also been carried out with the help of RETScreen software to determine the savings in greenhouse gas emissions as a result of PV system. Design/methodology/approach This study examines the buildings of the university campus for utilizable rooftop areas for PV application. Various types of structural, architectural and utilities-related features affecting the use of building roofs for PV have been investigated to determine the corrected area. To optimize the performance of the PV system as well as space utilization, modeling has been carried out for both horizontal and tilted applications of panels. Detailed economic and environmental assessments of the rooftop PV systems have also been investigated in detail. Modern software tools such as PVsyst, ArcGIS and RETScreen have also been used for system design calculations. Findings Saudi Arabia is embarking on a massive solar energy program as it plans to have over 200 GW of installed capacity by 2030. With solar energy being the most abundant of the available renewable resource for the country, PV is going to be one of the main technologies in achieving the set targets. The country has, however, unlike global trends, traditionally overlooked the small-scale and building-related application of solar PV, focusing mainly on larger projects. This study explores the prospects of utilization of solar PV on building roofs. Building rooftops are constrained in terms of PV application owing to wide ranging obstacles that can be classified into five types – structural, services, accessibility, maintenance and others. The total building rooftop area in the study zone, calculated through ArcGIS has been found to be 857,408 m2 of which 352,244 m2 is being used as car parking and hence is not available for PV application. The available roof area, 505,165 m2 is further hampered by construction and utilities related features including staircases, HVAC systems, skylights, water tanks and satellite dish antennas. Taking into account the relevant obstructive features, the net rooftop area covered by PV panels has been found to be in the range 25–41 percent depending upon the building typology, with residential buildings offering the least. To optimize both the system efficiency and space utilization, PV modeling has been carried out with the help of PVsyst software for both the tilted and horizontal installations. In terms of output, PV panels with tilt angle of 24° have been found to be 9 percent more efficient compared to the horizontally installed ones. Modeling results provide a net annual output 37,750 and 46,050 MWh from 21.44 and 28.51 MW of tilted and horizontal application of PV panels, sufficient to respectively meet 16 and 20 percent of the total campus electricity requirements. Findings of the economic analysis reveal the average SPP for horizontal and tilted applications of the PV to be 9.2 and 8.4 years, respectively. The benefit cost ratio for different types of buildings for horizontal and tilted application has been found to be ranging between 0.89 and 2.08 and 0.83 and 2.15, respectively. As electricity tariff in Saudi Arabia has been increased this year by as much as 45 percent and there are plans to remove $54bn of subsidy by 2020, the cost effectiveness of PV systems will be greatly helped. Application of PV in buildings can significantly improve their environmental performance as the findings of this study reveal that the annual greenhouse gas emission in the KFUPM campus can be reduced by as much as 40,199 tons carbon dioxide equivalent. Originality/value The PV application on building roof especially from economic perspective is an area which has not been addressed thus far. Khan et al. (2017) studied the power generation potential for PV application on residential buildings in KSA. Asif (2016) also investigated power output potential of PV system in different types of buildings. Dehwas et al. (2018) adopted a detailed approach to determine utilizability of PV on residential building roofs. None of these studies have covered the economics of PV systems. This study attempts to address the gap and contribute to the scholarship on the subject. It targets to determine the power output from different types of building in an urban environment by taking into account building roof conditions. It also provides detailed economic assessment of PV systems. Subsequent environmental savings are also calculated.


Smart Cities ◽  
2020 ◽  
Vol 3 (3) ◽  
pp. 842-852
Author(s):  
Moein Hajiabadi ◽  
Mahdi Farhadi ◽  
Vahide Babaiyan ◽  
Abouzar Estebsari

The demand for renewable energy generation, especially photovoltaic (PV) power generation, has been growing over the past few years. However, the amount of generated energy by PV systems is highly dependent on weather conditions. Therefore, accurate forecasting of generated PV power is of importance for large-scale deployment of PV systems. Recently, machine learning (ML) methods have been widely used for PV power generation forecasting. A variety of these techniques, including artificial neural networks (ANNs), ridge regression, K-nearest neighbour (kNN) regression, decision trees, support vector regressions (SVRs) have been applied for this purpose and achieved good performance. In this paper, we briefly review the most recent ML techniques for PV energy generation forecasting and propose a new regression technique to automatically predict a PV system’s output based on historical input parameters. More specifically, the proposed loss function is a combination of three well-known loss functions: Correntropy, Absolute and Square Loss which encourages robustness and generalization jointly. We then integrate the proposed objective function into a Deep Learning model to predict a PV system’s output. By doing so, both the coefficients of loss functions and weight parameters of the ANN are learned jointly via back propagation. We investigate the effectiveness of the proposed method through comprehensive experiments on real data recorded by a real PV system. The experimental results confirm that our method outperforms the state-of-the-art ML methods for PV energy generation forecasting.


Electronics ◽  
2021 ◽  
Vol 10 (9) ◽  
pp. 1121
Author(s):  
Kamran Ali Khan Niazi ◽  
Yongheng Yang ◽  
Tamas Kerekes ◽  
Dezso Sera

A reconfiguration technique using a switched-capacitor (SC)-based voltage equalizer differential power processing (DPP) concept is proposed in this paper for photovoltaic (PV) systems at a cell/subpanel/panel-level. The proposed active diffusion charge redistribution (ADCR) architecture increases the energy yield during mismatch and adds a voltage boosting capability to the PV system under no mismatch by connected the available PV cells/panels in series. The technique performs a reconfiguration by measuring the PV cell/panel voltages and their irradiances. The power balancing is achieved by charge redistribution through SC under mismatch conditions, e.g., partial shading. Moreover, PV cells/panels remain in series under no mismatch. Overall, this paper analyzes, simulates, and evaluates the effectiveness of the proposed DPP architecture through a simulation-based model prepared in PSIM. Additionally, the effectiveness is also demonstrated by comparing it with existing conventional DPP and traditional bypass diode architecture.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4150
Author(s):  
Lluís Monjo ◽  
Luis Sainz ◽  
Juan José Mesas ◽  
Joaquín Pedra

Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations.


Sign in / Sign up

Export Citation Format

Share Document