scholarly journals Soft Tissue Evaluation of an Immediate Esthetic Zone Single Implant with a Stereolithographic Guide Using 3D Reconstruction and a CAD/CAM Customized Titanium Anatomic Abutment

2020 ◽  
Vol 10 (5) ◽  
pp. 1678
Author(s):  
Tae-Heung Kim ◽  
You-Kyoung Oh ◽  
Chang-Mo Jeong ◽  
Edward Chengchuan Ko ◽  
George K. Sándor ◽  
...  

The replacement of an unrestorable tooth with a single implant-supported prosthesis is a treatment with predictable and successful outcomes. The anterior maxilla region is a complicated site for such treatment, due to its esthetic, functional, and physiological sensitivity. The purpose of this study was to evaluate the changes in the soft tissue following an immediate implant procedure using guided surgery in combination with a computer-aided design and computer-aided manufacturing (CAD/CAM) customized titanium anatomic abutment in the esthetic zone. A total of 13 patients who had been treated with an immediate post-extraction implant placement and an immediate provisional restoration were included in the study. The changes in the soft tissue dimension, interdental papilla, and esthetic score were evaluated with a follow-up of at least one year. There was no significant change in the midfacial mucosal status when compared to the pre-treatment situation. The recession of the mesial papillary height was 0.32 mm and the distal papillary height was 0.10 mm. The mean horizontal change in the labial mucosa was 0.32 ± 0.83 mm. There was no significant difference between the mesial papilla index and the distal papilla index. The pink esthetic score value prior to treatment was 11.16, and at one-year follow-up, 10.25. Within the limitations of this study, the immediate post-extraction implant placement procedure with a stereolithographic guide and a provisionalization with a CAD/CAM customized titanium anatomic abutment may be a treatment option with predictable outcomes for the replacement of teeth in the esthetic zone.

Materials ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 3874 ◽  
Author(s):  
Marco Tallarico ◽  
Chang-Joo Park ◽  
Aurea Immacolata Lumbau ◽  
Marco Annucci ◽  
Edoardo Baldoni ◽  
...  

Alveolar-ridge augmentation, anterior aesthetics, and digital technologies are probably the most popular topics in the dental-implant field. The aim of this report is to present a clinical case of severe atrophy of the anterior maxilla in a younger female patient, treated with a titanium membrane customized with computer-aided design/computer-aided manufacturing (CAD/CAM), simultaneous guided implant placement, and a fully digital workflow. A young female patient with a history of maxillary trauma was treated and followed-up for 1 year after implant placement. A narrow implant was inserted in a prosthetically driven position with the aid of computer-guided surgery. In the same surgical section, a customized implantable titanium mesh was applied. The scaffold was designed according to the contralateral maxillary outline in order to recreate a favorable maxillary bone volume. Finally, highly aesthetic, CAD/CAM, metal-free restorations were delivered using novel digital technologies.


2015 ◽  
Vol 41 (4) ◽  
pp. 450-458 ◽  
Author(s):  
Alessandro Pozzi ◽  
Marco Tallarico ◽  
Alberto Barlattani

This study was carried on to assess the clinical performance of a novel restorative concept consisting in single monolithic lithium disilicate full-contour crowns bonded on computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia complete-arch implant bridges, to overcome the drawbacks related to the chipping of porcelain fused to zirconia restorations. Sixteen patients received 18 implant-supported hybrid screw-cement-retained complete-arch restorations, consisting of single monolithic lithium disilicate full-contour crowns bonded on CAD/CAM zirconia frameworks. The restorations were supported by 4–8 implants. All patients were followed up for at least 3 years on function (range 36 to 60 months, mean 49.3 months). Clinical controls were scheduled every 4 months. The outcomes were implant and prosthetic survival and success rates, any complications, patient satisfaction, and soft tissue parameters. No dropouts occurred. The overall implant and prosthesis survival rates were 100%. One of 18 restorations (1 of 236 dental units) showed a chip-off fracture of the veneering ceramic that was polished intraorally without any additional treatment, scoring a cumulative prosthetic success rate of 100%, according to the California Dental Association index. All patients were functionally and esthetically highly satisfied with their restorations. Successful soft tissue parameters were found around all implants. Single monolithic lithium disilicate full-contour crowns, bonded on CAD/CAM screw-retained complete-arch zirconia frameworks, showed favorable preliminary outcomes with medium-term follow-up. However, randomized controlled studies of this technique are required for further conclusive recommendations.


2021 ◽  
Vol 6 (11) ◽  

Background: Most dental trauma in children and adolescents involve anterior tooth fractures. Advancements in ceramics technology and in computer-aided design/computer-aided manufacturing (CAD/CAM) systems, have led to the technological abilities to produce single all-ceramic crowns with high biocompatibility, esthetics, and optimal mechanical properties. However, there is no information regarding the use of this technique in children. Case report:Treatment of extensive crown fractures on an 11 years old patient using a chairside CAD/CAM technology. The teeth were scanned and the restorations were fabricated using the manufacturing unit of the CAD/CAM system and glazed to the appropriate tooth color. At a follow up visits the restorations kept their strength and esthetic appearance (one year follow up). Conclusion: The digital restoration treatment is especially suitable for treating children with dental trauma. It has the advantage of better esthetic, functional and durable results compering to conventional restorations, and it often requires only a single session.


2021 ◽  
Author(s):  
CA Jurado ◽  
A Tsujimoto ◽  
H Watanabe ◽  
NG Fischer ◽  
JA Hasslen ◽  
...  

SUMMARY Objective: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. Method: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. Results: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. Conclusions: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


Author(s):  
Khaled E. Ahmed

The potential applications of computer-aided design/computer-aided manufacturing (CAD/CAM) and intraoral scanning exceed the delivery of standard prosthodontic interventions. The aim of this study was to clinically present a developed assessment technique, that relies on the use of sequential intraoral scanning, three-dimensional superimposition, and 2D and 3D deviation analyses based on a standardised protocol, as an auxiliary tool in monitoring dimensional changes of residual ridge post-extraction with a follow-up period of four months.


2016 ◽  
Vol 40 (4) ◽  
pp. 264-268 ◽  
Author(s):  
Mehmet Selim Bilgin ◽  
Ali Erdem ◽  
Mehmet Tanrıver

Objective: The aim of this case report is to describe the treatment of a primary molar with a deep carious lesion by pulpotomy and placement of a ceramic endocrown. Clinical case: A 7-year-old male patient with profound caries in tooth number 85 was referred to our clinic and underwent a pulpotomy. As the final treatment in tooth restoration, placement of an endocrown was planned, because little more than half of the tooth structure remained. After an additional request from the patient's parents for an advanced and prompt restoration, a computer-aided design/computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic network (PICN) block was chosen. A three-dimensional model of the arch was obtained after scanning the dental cast, and the endocrown was designed digitally according to the model. When the design was complete, the endocrown was fabricated with a milling machine. Finally, the endocrown was cemented with self-adhesive resin cement. Results: Over the 9-month follow-up period, no pulpal or periradicular pathology was observed on radiographs. Regarding the crown, the marginal fit was excellent, the anatomical form was protected, and no discoloration occurred. Conclusion: During follow-up, the CAD/CAM PICN block endocrown proved to be a good material for the short- to long-term treatment of a primary tooth. However, more clinical cases and follow-up are required to investigate the long-term effects of antagonistic tooth wear.


2018 ◽  
Vol 43 (4) ◽  
pp. 437-446 ◽  
Author(s):  
NG Fischer ◽  
A Tsujimoto ◽  
AG Baruth

SUMMARY Objective: Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. Purpose: To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. Methods: One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. Results: AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. Conclusions: These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.


2019 ◽  
Vol 18 ◽  
pp. e191573
Author(s):  
Silas Monteiro Borges ◽  
Stephanie Francoi Poole ◽  
Izabela Cristina Maurício Moris ◽  
Aloísio Oro Spazzin ◽  
Adriana Cláudia Lapria Faria ◽  
...  

Aim: This study evaluated the mechanical behavior of implant-supported crowns obtained by different fabrication technique after thermomechanical cycling. Methods: Thirty-two external hexagon dental implants were divided into four groups (n=10): CC – conventional casting with torch; EI – electromagnetic induction casting; PL – plasma casting; and CAD-CAM – milling through computer-aided design and computer-aided manufacturing. Vickers microhardness of the specimens were made before and after the thermomechanical cycling, and then subjected to fracture load. Fracture pattern was evaluated. Results: No significant difference was observed comparing the microhardness before and after thermomechanical cycling. CAD-CAM group presented significant lower microhardness than the other groups. No significant statistical difference was showed on fracture load between the groups. The CAD-CAM and PL presented lower number of failure by plastic deformation. Conclusion: The manufacturing techniques affected the mechanical behavior and the failure pattern of implant-supported crowns tested.


Scanning ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Hong Xin Cai ◽  
Qi Jia ◽  
HaoYu Shi ◽  
Yujie Jiang ◽  
Jingnan Xue ◽  
...  

With the popularization of digital technology and the exposure of traditional technology’s defects, computer-aided design and computer-aided manufacturing (CAD/CAM) has been widely used in the field of dentistry. And the accuracy of the scanning system determines the ultimate accuracy of the prosthesis, which is a very important part of CAD/CAM, so we decided to evaluate the accuracy of the intraoral and extraoral scanners. In this study, we selected the sphere model as the scanning object and obtained the final result through data analysis and 3D fitting. In terms of trueness and precision, the scanner of SHINING was significantly different from that of others; however, there was no significant difference between TRIOS and CEREC. SHINING showed the lowest level of accuracy, with CEREC slightly lower than TRIOS. The sphere model has also been proven to be scanned successfully.


2020 ◽  
Author(s):  
Balazs Feher ◽  
Reinhard Gruber ◽  
Andre Gahleitner ◽  
Ales Celar ◽  
Philipp Luciano Necsea ◽  
...  

AbstractObjectivesCompletion of adolescent growth represents the earliest time point for implant placement, yet craniofacial growth persists into adulthood and may affect implant position. We aimed to assess whether implants placed in the anterior maxillae of adults show angular changes.MethodsWe conducted a cephalometric pilot study in postpubertal patients with no growth disorders, skeletal malformations, or parafunctions. The patients received a single implant in the anterior maxilla and no orthodontic or orthognathic treatment afterwards. We measured angular changes on cephalograms taken immediately and at least 5 years postoperatively in a standardized setting.ResultsIn a total of 21 patients (30.2 ± 11.5 years at surgery) after a mean follow-up time of 8.6 ± 1.3 years, 62% of implants showed counterclockwise rotations (1.8 ± 1.0 degrees) and 19% of implants showed clockwise rotations (2.4 ± 1.1 degrees). Angular changes were more frequent in males (100% vs. 58%) and patients under 30 at surgery (85% vs. 63%). Mean absolute differences were larger in males (1.8 ± 1.0 degrees vs. 1.3 ± 1.4 degrees) and patients under 30 at surgery (1.5 ± 1.4 degrees vs. 1.1 ± 1.4 degrees). Regression analysis did not identify explanatory factors for the observed changes.ConclusionsImplants placed in the anterior maxillae of adults show modest angular changes over time.Clinical relevanceChanges in implant angles have potential functional and esthetic consequences.


Sign in / Sign up

Export Citation Format

Share Document