scholarly journals Influence of Vacuum Level on Heat Transfer Characteristics of Maglev Levitation Electromagnet Module

2020 ◽  
Vol 10 (3) ◽  
pp. 1106 ◽  
Author(s):  
Yiqian Mao ◽  
Mingzhi Yang ◽  
Tiantian Wang ◽  
Fan Wu ◽  
Bosen Qian

The vacuum tube transportation (VTT) system has been a promising direction of future transportation. Within this system, a high-speed maglev travels in a low-vacuum environment to reduce aerodynamic drag. However, the heat dissipation of on-board heating devices will be compromised under low-vacuum conditions, and the device performance may thus be lowered. This study investigates the low-vacuum conjugate heat transfer characteristic of a levitation electromagnet module of a maglev using an experimentally verified numerical method. During the heating process, the surface temperature distribution of the levitation electromagnet, and the temperature and velocity characteristics of the flow field are examined. It is found that, as the vacuum level increases from 1.0 atm to 0.1 atm, the total heat dissipating from the levitation electromagnet module is decreased by 49% at 60 min, the contribution of convection heat flux over the total heat flux is decreased from 49% to 17%, and the convection heat transfer coefficient of the levitation electromagnet is decreased by 89%. This study can provide an efficient numerical model for low-vacuum heat transfer study on a VTT system as well as help the evaluation and optimization of low-vacuum maglev thermal management systems.

2011 ◽  
Vol 383-390 ◽  
pp. 6561-6567
Author(s):  
Zi Long Wang ◽  
Hua Zhang ◽  
Hai Tao Zhang

Aiming at the problem of the concentrating solar cell efficiency restricted by the temperature. The closed two-phase thermosyphon could be used for heat dissipation in concentrat- ing solar cell with high heat flux, then water was selected as the working fluid. Numerical computation methods were adopted to study heat transfer performance of the finned heat pipe radiator in free convection. The temperature field, velocity field, total heat dissipating capacity of different fin pitch and side length as well as free convection heat transfer coefficient under the condition of constant temperature of parent tube were obtained. As a result, the fin side length had greater impact on the natural convection heat transfer coefficient and average total heat flux per unit area; the fin pitch had greater impact on the finned heat pipe radiator total heat dissipating capacity per unit length; the finned heat pipe radiator was the best when fin pitch was 3mm and fin side length was 90mm.


Author(s):  
Chen-Ru Zhao ◽  
Zhen Zhang ◽  
Qian-Feng Liu ◽  
Han-Liang Bo ◽  
Pei-Xue Jiang

Numerical investigations are performed on the convection heat transfer of supercritical pressure fluid flowing through vertical mini tube with inner diameter of 0.27 mm and inlet Reynolds number of 1900 under various heat fluxes conditions using low Reynolds number k-ε turbulence models due to LB (Lam and Bremhorst), LS (Launder and Sharma) and V2F (v2-f). The predictions are compared with the corresponding experimentally measured values. The prediction ability of various low Reynolds number k-ε turbulence models under deteriorated heat transfer conditions induced by combinations of buoyancy and flow acceleration effects are evaluated. Results show that all the three models give fairly good predictions of local wall temperature variations in conditions with relatively high inlet Reynolds number. For cases with relatively low inlet Reynolds number, V2F model is able to capture the general trends of deteriorated heat transfer when the heat flux is relatively low. However, the LS and V2F models exaggerate the flow acceleration effect when the heat flux increases, while the LB model produces qualitative predictions, but further improvements are still needed for quantitative prediction. Based on the detailed flow and heat transfer information generated by simulation, a better understanding of the mechanism of heat transfer deterioration is obtained. Results show that the redistribution of flow field induced by the buoyancy and flow acceleration effects are main factors leading to the heat transfer deterioration.


Author(s):  
Jafar Madadnia

In the absence of a simple technique to predict convection heat transfer on building integrated photovoltaic (BIPV) surfaces, a mobile probe with two thermocouples was designed. Thermal boundary layers on vertical flat surfaces of a photovoltaic (PV) and a metallic plate were traversed. The plate consisted of twelve heaters where heat flux and surface temperature were controlled and measured. Uniform heat flux condition was developed on the heaters to closely simulate non-uniform temperature distribution on vertical PV modules. The two thermocouples on the probe measured local air temperature and contact temperature with the wall surface. Experimental results were presented in the forms of local Nusselt numbers versus Rayleigh numbers “Nu=a * (Ra)b”, and surface temperature versus dimensionless height [Ts -T∞= c*(z/h)d]. The constant values for “a”, “b”, “c” and “d” were determined from the best curve-fitting to the power-law relation. The convection heat transfer predictions from the empirical correlations were found to be in consistent with those predictions made by a number of correlations published in the open literature. A simple technique is then proposed to employ two experimental data from the probe to refine empirical correlations as the operational conditions change. A flexible technique to update correlations is of prime significance requirement in thermal design and operation of BIPV modules. The work is in progress to further extend the correlation to predict the combined radiation and convection on inclined PVs and channels.


2013 ◽  
Vol 448-453 ◽  
pp. 3316-3319
Author(s):  
Chuang Sun ◽  
Yang Zhao ◽  
De Fu Li ◽  
Qing Ai ◽  
Xin Lin Xia

According to the view of heat transfer, the process of the fluid flow with high temperature and high speed over a flat plate may be considered as the heat transfer process within a compressible thermal boundary layer. Based on the numerical results of thermal isolation assumption, combining the temperature comparison with modification method, a coupled method of convection heat transfer coefficient with temperature field of the plate is established, and the characteristics of the thermal response for the flat plate is dominated. Take some ribbed plates as instances, the convection heat transfer coefficient and temperature field of the plate are simulated through the provided coupled method. The results show that, not only the position and materials of the plate influence the convection heat transfer coefficient, but also the time.


1983 ◽  
Vol 105 (2) ◽  
pp. 350-357 ◽  
Author(s):  
P. J. Giarratano ◽  
W. G. Steward

Transient forced convection heat transfer coefficients for both subcritical and supercritical helium in a rectangular flow channel heated on one side were measured during the application of a step in heat flux. Zero flow data were also obtained. The heater surface which served simultaneously as a thermometer was a fast response carbon film. Operating conditions covered the following range: Pressure, 1.0 × 105 Pa (1 bar) to 1.0 × 106 Pa (10 bar); Temperature, 4 K–10 K; Heat Flux, 0.1 W/cm2−10 W/cm2; Reynolds number, 0–8 × 105. The experimental data and a predictive correlation are presented.


2021 ◽  
Vol 39 (3) ◽  
pp. 817-824
Author(s):  
Ameer Abed Jaddoa

This paper analyzes the effect of fluid flow characteristics on the convection heat transfer for mini-helically coiled tubes (HCT) using supercritical carbon dioxide (CO2) as a natural refrigerant. Two experimental cases have studied in this work for mini-helically coiled tubes at different diameters with different coil pitches for analyzing the convection heat transfer with flow resistance. In the first case, the inner tube diameter, coil diameter and coil pitch were 5 mm, 200 mm and 10 mm respectively, while 10 mm, 100 mm and 5 mm were for the second case. Moreover, this work has also investigated the influence of frictional pressure drop, heat flux, friction factor and mass flux on dimensionless exergy destruction. The work environments were 300-500 K as an inlet temperatures range, 200-2000 Kg / (m2. s) as a mass heat fluxes range, 50,000-500,000 as a Reynolds number (Re) range and 50-200 Kw/m2 as an inner heat fluxes range. As a result, a large effect has been observed for dimensionless exergy destruction compared with the flow friction of CO2 which induced by heat transfer irreversibility. On the other point of view, a good sensitivity of optimal Re with the tube dimeter and mass flux also noticed compared with the heat flux. At a suitable range for Re, smallest and best exergy destruction also noticed for the tube diameters. A correlation has for the optimal Reynolds number as function of main dimensionless parameters related to wall heat flux, mass flux, fluid properties and geometric dimensions is proposed. Characteristics of the fluid flow had influenced significantly by mass and heat fluxes. In the future, the collected experimental data can be employed in order to design and improve the refrigeration conditioning performance for exchangers and other systems such as heat pumps.


Sign in / Sign up

Export Citation Format

Share Document