scholarly journals Mechanical and Heterogeneous Properties of Coal and Rock Quantified and Mapped at the Microscale

2020 ◽  
Vol 10 (1) ◽  
pp. 342 ◽  
Author(s):  
Changlun Sun ◽  
Guichen Li ◽  
Suhui Zhang ◽  
Jiahui Xu ◽  
Houqiang Yang

Due to the impossibility of obtaining intact standard experimental samples, it is difficult to test the mechanical properties of soft and broken coal and rock obtained from deep coal mines. So, an advanced experimental technology based on a small sample volume, nanoindentation technology, was introduced and used to measure the mechanical parameters of them. By using the averaging method, the hardness of shale, mudstone and coal are 1191.90 MPa, 674.95 MPa and 424.30 MPa, respectively; their elastic moduli are 20.39 GPa, 11.72 GPa and 5.47 GPa; and their fracture toughness were 1.66 MPa·m0.5, 1.28 MPa·m0.5 and 0.77 MPa·m0.5. These three mechanical parameters were used to quantify and map the heterogeneous properties of coal and rock for convenience and accuracy. For example, the inter quartile range (IQR) of the hardness of shale, mudstone, and coal are 1502.10 MPa, 1016.20 MPa and 54.64 MPa, respectively, meaning that coal has the best homogeneity among them. Nanoindentation technology provides researchers with a convenient method to conduct mechanical experiments at the microscale.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Komal Chaudhary ◽  
Pooja Munjal ◽  
Kamal P. Singh

AbstractAlthough, many conventional approaches have been used to measure viscosity of fluids, most methods do not allow non-contact, rapid measurements on small sample volume and have universal applicability to all fluids. Here, we demonstrate a simple yet universal viscometer, as proposed by Stokes more than a century ago, exploiting damping of capillary waves generated electrically and probed optically with sub-nanoscale precision. Using a low electric field local actuation of fluids we generate quasi-monochromatic propagating capillary waves and employ a pair of single-lens based compact interferometers to measure attenuation of capillary waves in real-time. Our setup allows rapid measurement of viscosity of a wide variety of polar, non-polar, transparent, opaque, thin or thick fluids having viscosity values varying over four orders of magnitude from $$10^{0}{-}10^{4}~\text{mPa} \, \text{s}$$ 10 0 - 10 4 mPa s . Furthermore, we discuss two additional damping mechanisms for nanomechanical capillary waves caused by bottom friction and top nano-layer appearing in micro-litre droplets. Such self-stabilized droplets when coupled with precision interferometers form interesting microscopic platform for picomechanical optofluidics for fundamental, industrial and medical applications.


2005 ◽  
Vol 498-499 ◽  
pp. 506-511 ◽  
Author(s):  
Maria do Carmo de Andrade Nono

CeO2- ZrO2 ceramics are considered a candidate material for applications as structural high performance ceramics. In this work are presented and discussed the tetragonal-to-monoclinic stress-induced transformation influence on the mechanical properties in these ceramics. Sintered ceramics were fabricated from powders mixtures containing ZrO2 and 8 to 14 CeO2 % mol. SEM observations were used to study de ceramic microstructures and X-rays diffraction to identification and determination of tetragonal and monoclinic phases. It was adopted the 4-point bending tests, Vickers surface hardness and fracture toughness technique to the determination of the mechanical parameters. The results showed that the mechanical properties were strongly dependent of the CeO2 content, the microstructure and the fraction of tetragonal-to-monoclinic stress-induced transformation.


Antibiotics ◽  
2020 ◽  
Vol 9 (10) ◽  
pp. 655
Author(s):  
Matthew D. Simmons ◽  
Lisa M. Miller ◽  
Malin O. Sundström ◽  
Steven Johnson

The misuse of antibiotics in health care has led to increasing levels of drug resistant infections (DRI’s) occurring in the general population. Most technologies developed for the detection of DRI’s typically focus on phenotyping or genotyping bacterial resistance rather than on the underlying cause and spread of DRI’s; namely the misuse of antibiotics. An aptameric based assay has been developed for the monitoring of ampicillin in urine samples, for use in determining optimal antibiotic dosage and monitoring patient compliance with treatment. The fluorescently labelled aptamers were shown to perform optimally at pH 7, ideal for buffered clinical urine samples, with limits of detection as low as 20.6 nM, allowing for determination of ampicillin in urine in the clinically relevant range of concentrations (100 nM to 100 µM). As the assay requires incubation for only 1 h with a small sample volume, 50 to 150 µL, the test would fit within current healthcare pathways, simplifying the adoption of the technology.


1996 ◽  
Vol 42 (5) ◽  
pp. 704-710 ◽  
Author(s):  
J W Eastman ◽  
R Wong ◽  
C L Liao ◽  
D R Morales

Abstract Automated HPLC is used to test dried blood-spot specimens from newborns for hemoglobins (Hb) F, A, S, C, E, and D. We present the method and report on its performance determined during >4 years of testing 2.5 x 10(6) newborns. The method features automated derivation of presumptive phenotypes; quantitative quality control and proficiency testing; throughput of one specimen per minute; small sample volume; hemoglobin concentrations quantified with an interlaboratory CV of 14-18%; retention times with interlaboratory CV of <2% and matching, within +/- 0.03 min, of laboratories and reagent lots; control of peak resolution; 0.5% detection limit for Hb S and C, and 1.0% for Hb F, A, E, and D; few interferences; and negligible background and carryover. Shortcomings of the method are the absence of microplate barcode identification and the need for manually pipetting the sample eluate into the microplate.


1984 ◽  
Vol 30 (9) ◽  
pp. 1473-1476 ◽  
Author(s):  
M P Maskarinec ◽  
M J Sepaniak ◽  
A T Balchunas ◽  
J D Vargo

Abstract Liquid chromatography in open tubes is evaluated for applicability to clinical analysis. The principal advantages of this technique include high separation power, reduced solvent consumption, and small sample volume requirements. Technology for the production of columns as small as 8 micron (i.d.) is described. Preliminary results are encouraging and, with further development in column and detector technology, the technique should find wide applicability in clinical analysis.


Author(s):  
Yoshihiro Taguchi ◽  
Koichi Itani ◽  
Akira Ebisui ◽  
Yuji Nagasaka

Micro-electro mechanical systems (MEMS) biochips realizing high-speed and high-efficiency of reaction and analysis attract much attention in medical as well as chemical fields. Especially, the miniaturized devices enabling small sample volume, arrayed, and portable measurement may become a powerful tool for material analysis and process control. We have proposed a novel micro optical diffusion sensor (MODS) which enables small sample volume, highspeed and non-contact measurement of diffusion coefficient of liquid sample. MODS consists of a pair of transparent electrodes (Al-doped Zinc oxide: AZO), a photoconductive layer (amorphous silicon: a-Si:H), two MEMS mirrors and excitation and probing fibers for inducing and detecting concentration distribution. The initial concentration distribution of sample is created by an opto-dielectrophoretic (opto-DEP) manipulation along with a sinusoidal pattern of irradiated beam on a photoconductive layer. In the present paper, the measurement principle is proposed, and the preliminary experiment using a bench top apparatus is reported.


1986 ◽  
Vol 32 (7) ◽  
pp. 1407-1409 ◽  
Author(s):  
T Annesley ◽  
K Matz ◽  
L Balogh ◽  
L Clayton ◽  
D Giacherio

Abstract This liquid-chromatographic assay requires 0.2 to 0.5 mL of whole blood, avoids the use of diethyl ether, and consumes only 10 to 20% of the solvents used in prior methods. Sample preparation involves an acidic extraction with methyl-t-butyl ether, performed in a 13 X 100 mm disposable glass tube, then a short second extraction of the organic phase with sodium hydroxide. After evaporation of the methyl-t-butyl ether, chromatography is performed on an "Astec" 2.0-mm (i.d.) octyl column. We compared results by this procedure with those by use of earlier larger-scale extractions and their respective 4.6-mm (i.d.) columns; analytical recoveries of cyclosporins A and D were comparable with previous findings and results for patients' specimens were equivalent, but the microbore columns provided greatly increased resolution and sensitivity.


2015 ◽  
Vol 120 ◽  
pp. 171-174 ◽  
Author(s):  
Erwin K. Reichel ◽  
Ali Abdallah ◽  
Christian Feichtenschlager ◽  
Martin Kramer ◽  
Andreas Moritz ◽  
...  

Author(s):  
Alex Vary ◽  
Stanley J. Klima

An overview of nondestructive evaluation (NDE) is presented to indicate the availability and application potentials of techniques for quantitative characterization the mechanical properties of structural materials. The purpose of this brief survey is to review NDE techniques that go beyond the usual emphasis on flaw detection and characterization. This survey covers current and emerging NDE techniques that can verify and monitor entrinsic properties (e.g., tensile, shear, and yield strengths; fracture toughness, hardness; ductility; elastic moduli) and underlying microstructural and morphological factors. Most of the techniques described are, at present, neither widely applied nor widely accepted in commerce and industry because they are still emerging from the laboratory. The limitations of the techniques may be overcome by advances in applications research and instrumentation technology and perhaps by accommodations for their use in the design of structural parts.


Sign in / Sign up

Export Citation Format

Share Document