scholarly journals Automatic Extraction of Recurrent Patterns of High Dominant Frequency Mapping During Human Persistent Atrial Fibrillation

2021 ◽  
Vol 12 ◽  
Author(s):  
Xin Li ◽  
Gavin S. Chu ◽  
Tiago P. Almeida ◽  
Frederique J. Vanheusden ◽  
João Salinet ◽  
...  

Purpose: Identifying targets for catheter ablation remains challenging in persistent atrial fibrillation (persAF). The dominant frequency (DF) of atrial electrograms during atrial fibrillation (AF) is believed to primarily reflect local activation. Highest DF (HDF) might be responsible for the initiation and perpetuation of persAF. However, the spatiotemporal behavior of DF remains not fully understood. Some DFs during persAF were shown to lack spatiotemporal stability, while others exhibit recurrent behavior. We sought to develop a tool to automatically detect recurrent DF patterns in persAF patients.Methods: Non-contact mapping of the left atrium (LA) was performed in 10 patients undergoing persAF HDF ablation. 2,048 virtual electrograms (vEGMs, EnSite Array, Abbott Laboratories, USA) were collected for up to 5 min before and after ablation. Frequency spectrum was estimated using fast Fourier transform and DF was identified as the peak between 4 and 10 Hz and organization index (OI) was calculated. The HDF maps were identified per 4-s window and an automated pattern recognition algorithm was used to find recurring HDF spatial patterns. Dominant patterns (DPs) were defined as the HDF pattern with the highest recurrence.Results: DPs were found in all patients. Patients in atrial flutter after ablation had a single DP over the recorded time period. The time interval (median [IQR]) of DP recurrence for the patients in AF after ablation (7 patients) decreased from 21.1 s [11.8 49.7 s] to 15.7 s [6.5 18.2 s]. The DF inside the DPs presented lower temporal standard deviation (0.18 ± 0.06 Hz vs. 0.29 ± 0.12 Hz, p < 0.05) and higher OI (0.35 ± 0.03 vs. 0.31 ± 0.04, p < 0.05). The atrial regions with the highest proportion of HDF region were the septum and the left upper pulmonary vein.Conclusion: Multiple recurrent spatiotemporal HDF patterns exist during persAF. The proposed method can identify and quantify the spatiotemporal repetition of the HDFs, where the high recurrences of DP may suggest a more organized rhythm. DPs presented a more consistent DF and higher organization compared with non-DPs, suggesting that DF with higher OI might be more likely to recur. Recurring patterns offer a more comprehensive dynamic insight of persAF behavior, and ablation targeting such regions may be beneficial.

2012 ◽  
Vol 5 (4) ◽  
pp. 650-658 ◽  
Author(s):  
Julian W.E. Jarman ◽  
Tom Wong ◽  
Pipin Kojodjojo ◽  
Hilmar Spohr ◽  
Justin E. Davies ◽  
...  

Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Jiun Tuan ◽  
Suman Kundu ◽  
Mohamed Jeilan ◽  
Faizel Osman ◽  
Rajkumar Mantravadi ◽  
...  

Introduction & Hypothesis: Studies in catheter ablation of atrial fibrillation (AF) show that an increase in cycle length (CL) and higher organization index (OI) is associated with termination of AF. We hypothesize that similar changes can be seen in chemical cardioversion with Flecainide Methods: Patients who were still in AF at the end of catheter ablation for AF were given intravenous flecainide. OI and dominant frequency (DF) were obtained by Fast Fourier Transform of coronary sinus electrograms over 10s in AF, before and after flecainide infusion. Mean CL was also calculated. Results: 28 patients were identified (18 paroxysmal AF and 10 persistent AF). 8 cardioverted to sinus rhythm (SR) with flecainide. In all patients, mean CL increased from 211 ± 44 ms to 321 ± 85 ms (p <0.001). Mean DF decreased from 5.2 ± 1.03 Hz to 3.6 ± 1.04 Hz (p <0.001). Mean OI was 0.33 ± 0.13 before and 0.32 ± 0.11 after flecainide (p = 0.90). Comparing patients who cardioverted to SR with those who did not, OI post-flecainide was 0.41 ± 0.12 vs 0.29 ± 0.10 (p=0.013) and relative change in OI was 29 ± 33% vs −3.9 ± 27% (p=0.016) respectively. No significant difference was noted in the change in CL and DF in the 2 groups. Logistic regression showed that a greater relative increase in OI (p=0.04), a higher OI post-flecainide (p=0.03) and SR at start of procedure (p=0.03) are independently associated with cardioversion to SR with flecainide. Conclusion: Increase in OI, independent of changes to the CL and DF, appears critical to AF termination with flecainide. The increase in OI may reflect an increase in size and reduction in the number of re-entrant circuits, which together with slowing of atrial activation, result in return to SR.


2009 ◽  
Vol 20 (12) ◽  
pp. 1336-1342 ◽  
Author(s):  
SHELDON M. SINGH ◽  
E. KEVIN HEIST ◽  
JACOB S. KORUTH ◽  
CONOR D. BARRETT ◽  
JEREMY N. RUSKIN ◽  
...  

Heart Rhythm ◽  
2010 ◽  
Vol 7 (3) ◽  
pp. 295-302 ◽  
Author(s):  
Kentaro Yoshida ◽  
Aman Chugh ◽  
Eric Good ◽  
Thomas Crawford ◽  
James Myles ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document