scholarly journals Development and validation of a simple spectrophotometric method for quantification of chloride in polymeric materials

2015 ◽  
Vol 18 (2) ◽  
pp. 152-158
Author(s):  
Chau Minh Huynh ◽  
Nguyen Thao Nguyen ◽  
Vu Dinh Thien Vo ◽  
Mai Anh Nguyen

A simple analytical method was developed for determination of chloride content in polymeric materials. The procedure comprises of two steps, the dissolution of the polymer by alkaline fusion followed by indirect spectrophotometric analysis of the chloride based on the absorption at 460 nm of Fe(SCN)2+, a product of the reaction between chloride ion and a mixture of mercury (II) thiocyante and ferric ion. A non-linear calibration curve was constructed from 0.5 to 20 ppm with R2 = 0.9991; the limit of detection and quantitation were of 0.325 and 1.083 ppm, respectively. The recovery of the whole procedure was higher than 92.9 % with a RSD ~ 2.4 %. The developed procedure was applied to animated poly(divinylbenzene-co-vinyl benzyl chloride) in order to investigate the extent of amination of the base material.

Molecules ◽  
2020 ◽  
Vol 25 (18) ◽  
pp. 4109
Author(s):  
Haitham AlRabiah ◽  
Sabry M. Attia ◽  
Nasser S. Al-Shakliah ◽  
Gamal A. E. Mostafa

An accurate and simple HPLC-UV method has been developed for the determination of clonidine in mouse plasma. A reversed phase C18 Nova Pack® column (125 mm × 4.6 mm i.d., × 3 μm particle size) was used as stationary phase. The mobile phase composition was a mixture of 0.1% diethylamine/acetonitrile (70:30, v/v) at pH 8 in an isocratic mode at flow rate was 1.0 mL/min. Detection was set at 210 nm. Tizanidine was used as an internal standard. The clonidine and tizanidine were extracted from plasma matrix using the deproteinization technique. The developed method exhibited a linear calibration range 100.0–2000 ng/mL and the lower limit of detection (LOD) and quantification (LOQ) were 31.0 and 91.9 ng/mL, respectively. The intra-day and inter-day accuracy and precision of the method were within 8.0% and 3.0%, respectively, relative to the nominal concentration. The developed method was validated with respect to linearity, accuracy, precision, and selectivity according to the US Food and drug guideline. Minimal degradation was demonstrated during the determination of clonidine under different stability conditions. The suggested method has been successfully applied during a pharmacokinetic study of clonidine in mouse plasma.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


2017 ◽  
Vol 9 (5) ◽  
pp. 102
Author(s):  
Sukhjinder Kaur ◽  
Taranjit Kaur ◽  
Gurdeep Kaur ◽  
Shivani Verma

Objective: The aim of the present work was to develop a simple, rapid, accurate and economical UV-visible spectrophotometric method for the determination of hydroquinone (HQ) in its pure form, marketed formulation as well as in the prepared nanostructured lipid carrier (NLC) systems and to validate the developed method.Methods: HQ was estimated at UV maxima of 289.6 nm in pH 5.5 phosphate buffer using UV-Visible double beam spectrophotometer. Following the guidelines of the International Conference on Harmonization (ICH), the method was validated for various analytical parameters like linearity, precision, and accuracy robustness, ruggedness, limit of detection, quantification limit, and formulation analysis.Results: The obtained results of the analysis were validated statistically. Recovery studies were performed to confirm the accuracy of the proposed method. In the developed method, linearity over the concentration range of 5-40 μg/ml of HQ was observed with the correlation coefficient of 0.998 and found in good agreement with Beer Lambert’s law. The precision (intra-day and inter-day) of the method was found within official RCD limits (RSD<2%).Conclusion: The sensitivity of the method was assessed by determining the limit of detection and limit of quantification. It could be concluded from the results obtained that the purposed method for estimation of HQ in pure form, in the marketed ointment and in the prepared NLC-formulation was simple, rapid, accurate, precise and economical. It can be used successfully in the quality control of pharmaceutical formulations and for the routine laboratory analysis.


Author(s):  
LIPSA SAMAL ◽  
AMARESH PRUSTY

Objective: The aim of the present work was to develop and validate a simple UV spectroscopic method for the determination of duloxetine, which is a thiophene derivative and a selective neurotransmitter reuptake inhibitor for serotonin, norepinephrine, and to lesser degree dopamine. Methods: The UV Spectrophotometric analysis was performed using Shimadzu UV-1800 and Shimadzu UV-1700 spectrophotometer by using solvent system acetonitrile and water in the ratio of 8:2. Detection was performed at a wavelength of 290 nm. Method validation was carried out according to ICH Q2R1 guidelines by taking the parameters linearity, accuracy, precision, ruggedness, and robustness, LOD and LOQ. Results: The UV Spectrophotometric method was found linear in the range of 10-50 μg/ml. The method was rugged and robust with % relative standard deviation less than 2. The extraction recoveries were found to be higher than 99% in all experimental conditions. Conclusion: Based upon the performance characteristics, the proposed method was found accurate, precise and rapid and suitable for the determination of Duloxetine for routine analysis.


Author(s):  
Mrinalini C. Damle ◽  
Swapnil S Waghmare ◽  
PURUSHOTAM SINHA

Objective: To develop and validate simple, sensitive stability indicating HPTLC (High performance thin layer chromatography) method for apixaban. Methods: The chromatographic separation was performed on aluminium plates precoated with silica gel 60 F254 using toluene: ethyl acetate: methanol (3:6:1 v/v/v) as mobile phase followed by densitometric scanning at 279 nm. Results: The chromatographic condition shows sharp peak of apixaban at Rf value of 0.38±0.03. Stress testing was carried out according to international conference on harmonization (ICH)Q1A (R2) guidelines and the method was validated as per ICH Q2(R1) guidelines. The calibration curve was found to be linear in the concentration range of 100-500 ng/band for apixaban. The limit of detection and quantification was found to be 11.66ng/bandand35.33ng/band, respectively. Conclusion: A new simple, sensitive, stability indicating high performance thin layer chromatographic (HPTLC) method has been developed and validated for the determination of apixaban.


2007 ◽  
Vol 90 (3) ◽  
pp. 720-724
Author(s):  
Sevgi Tatar Ulu

Abstract A sensitive and selective high-performance liquid chromatographic method has been developed for the determination of tianeptine (Tia) in tablets. The method is based on derivatization of Tia with 4-chloro-7-nitrobenzofurazan (NBD-Cl). A mobile phase consisting of acetonitrile10 mM orthophosphoric acid (pH 2.5; 77 + 23) was used at a flow rate of 1 mL/min on a C18 column. The Tia-NBD derivative was monitored using a fluorescence detector, with emission set at 520 nm and excitation at 458 nm. Gabapentin was selected as an internal standard. Linear calibration graphs were obtained in the concentration range of 45300 ng/mL. The lower limit of detection (LOD) was 10 ng/mL at a signal-to-noise ratio of 4. The lower limit of quantitation (LOQ) was 45 ng/mL. The relative standard values for intra- and interday precision were &lt;0.46 and &lt;0.57%, respectively. The recovery of the drug samples ranged between 98.89 and 99.85%. No chromatographic interference from the tablet excipients was found. The proposed method was validated in terms of precision, robustness, recovery, LOD, and LOQ. All the validation parameters were within the acceptance range. The proposed method was applied for the determination of Tia in commercially available tablets. The results were compared with those obtained by an ultraviolet spectrophotometric method using t- and F-tests.


Author(s):  
Jaspreet Kaur ◽  
Daljit Kaur ◽  
Sukhmeet Singh

Objective: A simple, accurate, and selective ultraviolet-spectrophotometric method has been developed for the estimation of febuxostat in the bulk and pharmaceutical dosage forms.Method: The method was developed and validated according to International Conference on Harmonization (ICH Q2 R1) guidelines. The developed method was validated statistically with respect to linearity, range, precision, accuracy, ruggedness, limit of detection (LOD), limit of quantitation (LOQ), and recovery. Specificity of the method was demonstrated by applying different stressed conditions to drug samples such as acid hydrolysis, alkaline hydrolysis, oxidative, photolytic, and thermal degradation.Results: The study was conducted using phosphate buffer pH 6.8 and λmax was found to be 312 nm. Standard plot having a concentration range of 1–10 μg/ml showed a good linear relationship with R2=0.999. The LOD and LOQ were found to be 0.118 μg/ml and 0.595 μg/ml, respectively. Recovery and percentage relative standard deviations were found to be 100.157±0.332% and <2%, respectively.Conclusion: Proposed method was successfully applicable to the pharmaceutical formulations containing febuxostat. Thus, the developed method is found to be simple, sensitive, accurate, precise, reproducible, and economical for the determination of febuxostat in pharmaceutical dosage forms.


2020 ◽  
Vol 32 (9) ◽  
pp. 2208-2212
Author(s):  
CH. RAMESH ◽  
DHARMASOTH RAMA DEVI DEVI ◽  
M.N.B. SRINIVAS ◽  
S. RADHA KRISHNA ◽  
NAGARAJU RAJANA ◽  
...  

simple, specific, linear, accurate and precise reverse phase chiral HPLC method was developed for the separation of efavirenz enantiomers by using the Lux Amylose-2 column containing amylose tris(5-chloro-2-methyl phenyl carbamate) as a stationary phase. The mobile phase consists of 0.1 % formic acid in water and acetonitrile (55:45, v/v). The flow rate was kept at 1.0 mL/min and the detection wavelength used 252 nm and the column temperature was set at 25 ºC. The limit of detection was 0.01 mg/mL and the limit of quantification was 0.04 mg/mL. The linearity calibration curve of (R)-enantiomer was shown well from the range of 0.04 mg/mL to 0.4 mg/mL. The values of the correlation coefficient were 0.999 and 0.999 for (R)-enantiomer and (S)-efavirenz, respectively. The percentage recoveries of (R)-enantiomer from efavirenz drug substance were ranged from 93.5% to 107.5%. The results demonstrated that developed RP-chiral HPLC method was simple, precise, robust and applicable for the estimation of (R)-enantiomer in efavirenz API. This method was validated in as per ICH Q2 (R1) and USP validation of compendial methods <1225>.


2013 ◽  
Vol 19 (3) ◽  
pp. 333-337 ◽  
Author(s):  
A.C. Arvadiya ◽  
P.P. Dahivelker

A simple, precise, accurate, sensitive and repeatable RP-UPLC method was developed for quantitative determination of atropine sulphate in pharmaceutical dosage form. The method was developed by using C18 column Hiber HR Purospher Star (100mm?2.1mm id, 2?m particle size) as stationary phase with Phosphate Buffer: Acetonitrile (87:13, %v/v) as a mobile phase, pH was adjusted to 3.5 by ortho-phosphoric acid at a flow rate of 0.5 mL/min and column temperature maintained at 30?C. Quantification of eluted compound was achieved with PDA detector at 210 nm. Atropine sulphate followed linearity in concentration range of 2.5-17.5 ?g/mL with r2=0.9998 (n=6). Limit of detection (LOD) and limit of quantification (LOQ) values were 0.0033 and 0.0102 ?g/mL for atropine sulphate. The validation study is carried out as per International Conference on Harmonization (ICH) guidelines. This method was successfully applied for estimation of atropine sulphate in pharmaceutical formulation.