Ultrasound elastography for the detection of capsular fibrosis in breast implants: First results

Author(s):  
Ernst Jung ◽  
Vanessa Hösl ◽  
Sarah von Fraunberg ◽  
Friedrich Jung ◽  
Lukas Prantl

BACKGROUND: Capsular contractures around breast implants usually develop leading to pain and aesthetically inadequate results and ultimately often requires the replacement of the implants. Textured silicone implants are the most commonly placed implant, but polyurethane-coated implants are increasingly being used in an attempt to ameliorate the long-term complications associated with implant insertion. AIM: Capsular contracture is traditionally classified using the Baker scale, a subjective classification system based upon clinical findings. Aim of this study was to evaluate the association between pain due capsular contraction, Baker Score and different techniques of US elastography. MATERIAL AND METHODS: Patients were contacted who had undergone an implant replacement due to capsular contracture. Inclusion criterion was the re-implantation of a PU-coated implant. In the third year after changing the implant a follow-up examination was performed in 16 patients with 23 implants. A conventional examination with anamnesis, tactile and visual findings to obtain a Baker score, and ultrasound examinations including shear wave elastography, ARFI and compound elastography were performed. In addition, pain was evaluated using a visual analogue scale (VAS). RESULTS: The pain data showed a significant improvement (before implant exchange: 4.1±2.8 score points) with significance in favor of the current state (1.7±1.0 pain score points; p = 0.002). All patients suffered from less or no pain three years after exchange of the implant. Pain values and elastography (ARFI values) correlated well (r = 0,873), with increasing Baker score the ARFI values increased. US elastography evaluations can locally determine tissue density but correlate only to a limited extent with the test findings according to Baker. US elastography values of mammary gland tissue without implant did not differ from mammary gland tissue around implants. CONCLUSION: Preoperative Baker scores prior to exchange and the current Baker scores at the follow-up showed significantly lower score points three years after exchange of the implants. Ultrasound elastography seems to be an objective classification of capsular fibrosis. These first results motivate to initiate a prospective multicenter investigation.

2021 ◽  
pp. 106378
Author(s):  
Iolly Tábata Oliveira Marques ◽  
Fábio Roger Vasconcelos ◽  
Juliana Paula Martins Alves ◽  
Assis Rubens Montenegro ◽  
César Carneiro Linhares Fernandes ◽  
...  

1998 ◽  
Vol 11 (11) ◽  
pp. 1339-1345 ◽  
Author(s):  
Ryszard Jankowiak ◽  
Dan Zamzow ◽  
Douglas E. Stack ◽  
Rosa Todorovic ◽  
Ercole L. Cavalieri ◽  
...  

BMC Genomics ◽  
2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Johanna Brodhagen ◽  
Rosemarie Weikard ◽  
Ulrike Thom ◽  
Annika Heimes ◽  
Juliane Günther ◽  
...  

2012 ◽  
Vol 39 (7) ◽  
pp. 7311-7318 ◽  
Author(s):  
Changfa Wang ◽  
Ji Wang ◽  
Zhihua Ju ◽  
Ruiyan Zhai ◽  
Lei Zhou ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document