Behavior of implant and abutment sets of three different connections during the non-axial load application: An in vitro experimental study using a radiographic method

2021 ◽  
pp. 1-12
Author(s):  
Sergio Alexandre Gehrke ◽  
Berenice Anina Dedavid ◽  
José Manuel Granero Marín ◽  
Luigi Canullo

BACKGROUND: During the masticatory cycle, loads of different intensities and directions are received by the dental structures and/or implants, which can cause micromovements at the junction between the abutment and implant. OBJECTIVE: The objective of this in vitro study was to evaluate the behavior of three different implant connections subjected to different load values using a digital radiography system. Additionally, the torque values for removing the abutment screws were also measured and compared. METHODS: Ninety sets of implant and abutment (IA) were used, divided into three groups according to the type of connection (n = 30 per group): EH group, external hexagon type connection; IH group, internal hexagon connection; and, MT group, Morse taper connection. RESULTS: MT group showed the better vertical misfit behavior at the three intensity of load applied, in comparison with EH and IH groups. In the analysis of torque maintenance (detorque test), MT group showed higher values of detorque when compared with the measured values of EH and IH groups (p < 0.001). CONCLUSIONS: The IA sets of EH and IH groups showed a microgap in all levels of applied loads, unlike the MT group this event was not observed. In the detorque test, MT group increase in the torque values when compared to the initial torque applied, unlike EH and IH groups showed a decrease in the initially torque applied in all conditions tested. A positive correlation was detected between the misfit and detorque values.

2021 ◽  
Vol 10 (1) ◽  
pp. 1-8
Author(s):  
Zahra Dalili Kajan ◽  
◽  
Hamid Neshandar Asli ◽  
Negar Khosravifard ◽  
Maryam Bidvand ◽  
...  

Purpose: This study was designed to evaluate the diagnostic value of digital Bitewing (BW) radiographs with and without horizontal tube shift in detecting Residual excess cement (REC) on the proximal and non-proximal surfaces of implant restorations. Material and Methods: Eight mandibular models were fabricated with two implants placed on each side in the premolar and first molar positions. Excess cement was applied to either proximal or non-proximal surfaces of the restorations intentionally during the process of crown cementation. BW radiographs with and without applying horizontal tube shift were acquired. Three maxillofacial radiologists were asked to determine the presence and location of REC in the radiographs. Sensitivity and specificity of the radiographic technique were assessed according to the restoration surface that contained REC. Results: Sensitivity of BW radiographs was 100% for the detection of REC on the proximal surfaces and 41-18, 80% on the non-proximal surfaces. Specificity of the technique was 85.71%-100% for the proximal surfaces and 75-94. 12% for the non-proximal areas. Specificity of the radiographic method was generally greater than its sensitivity for the non-proximal surfaces while in the proximal areas, the two variables had quite similar values. Conclusion: Digital BW radiography is generally more useful for detection of REC on the proximal surfaces. Higher specificity of this technique for the bucco-lingual surfaces suggests more reliability of the negative diagnoses in the non-proximal areas.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Motaz Osman ◽  
Neamat Hassan Abubakr ◽  
Ahmed Suliman ◽  
Hassan Ziada

Abstract Aim This in vitro study aimed to evaluate the effect of implant impression coping geometrical designs on the accuracy of open and closed impression techniques and in the parallel and nonparallel implant positions. Material and methods Three custom-made acrylic resin models of three tested implant systems (Straumann®, SIC Invent®, and Osstem®) with diverse coping geometrical designs were evaluated in simulated cases of two parallel and two nonparallel implants. The horizontal and vertical discrepancies were measured and analyzed. Results No statistically significant differences between the two impression techniques in either parallel or nonparallel implants were observed. The high retentive design of the Osstem system showed a statistically significant difference. Conclusion The geometrical design of the impression copings did not affect the accuracy for either the open and closed tray techniques. However, the high retentive coping design of the Osstem implant affected the accuracy in the open tray technique.


Author(s):  
Ezio Bruna ◽  
Andrea Fabianelli ◽  
Giacomo Mastriforti ◽  
Federica Papacchini

2017 ◽  
Vol 32 (4) ◽  
pp. 822-829 ◽  
Author(s):  
Sergio Gehrke ◽  
Rafael Delgado-Ruiz ◽  
Juan Frutos ◽  
María Prados-Privado ◽  
Berenice Dedavid ◽  
...  