Real time fall detection using infrared cameras and reflective tapes under day/night luminance

Author(s):  
E. Ramanujam ◽  
S. Padmavathi

Falls are the leading cause of injuries and death in elderly individuals who live alone at home. The core service of assistive living technology is to monitor elders’ activities through wearable devices, ambient sensors, and vision systems. Vision systems are among the best solutions, as their implementation and maintenance costs are the lowest. However, current vision systems are limited in their ability to handle cluttered environments, occlusion, illumination changes throughout the day, and monitoring without illumination. To overcome these issues, this paper proposes a 24/7 monitoring system for elders that uses retroreflective tape fabricated as part of conventional clothing, monitored through low-cost infrared (IR) cameras fixed in the living environment. IR camera records video even when there are changes in illumination or zero luminance. For classification among clutter and occlusion, the tape is considered as a blob instead of a human silhouette; the orientation angle, fitted through ellipse modeling, of the blob in each frame allows classification that detects falls without pretrained data. System performance was tested using subjects in various age groups and “fall” or “non-fall” were detected with 99.01% accuracy.

Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2254
Author(s):  
Francisco Javier González-Cañete ◽  
Eduardo Casilari

Over the last few years, the use of smartwatches in automatic Fall Detection Systems (FDSs) has aroused great interest in the research of new wearable telemonitoring systems for the elderly. In contrast with other approaches to the problem of fall detection, smartwatch-based FDSs can benefit from the widespread acceptance, ergonomics, low cost, networking interfaces, and sensors that these devices provide. However, the scientific literature has shown that, due to the freedom of movement of the arms, the wrist is usually not the most appropriate position to unambiguously characterize the dynamics of the human body during falls, as many conventional activities of daily living that involve a vigorous motion of the hands may be easily misinterpreted as falls. As also stated by the literature, sensor-fusion and multi-point measurements are required to define a robust and reliable method for a wearable FDS. Thus, to avoid false alarms, it may be necessary to combine the analysis of the signals captured by the smartwatch with those collected by some other low-power sensor placed at a point closer to the body’s center of gravity (e.g., on the waist). Under this architecture of Body Area Network (BAN), these external sensing nodes must be wirelessly connected to the smartwatch to transmit their measurements. Nonetheless, the deployment of this networking solution, in which the smartwatch is in charge of processing the sensed data and generating the alarm in case of detecting a fall, may severely impact on the performance of the wearable. Unlike many other works (which often neglect the operational aspects of real fall detectors), this paper analyzes the actual feasibility of putting into effect a BAN intended for fall detection on present commercial smartwatches. In particular, the study is focused on evaluating the reduction of the battery life may cause in the watch that works as the core of the BAN. To this end, we thoroughly assess the energy drain in a prototype of an FDS consisting of a smartwatch and several external Bluetooth-enabled sensing units. In order to identify those scenarios in which the use of the smartwatch could be viable from a practical point of view, the testbed is studied with diverse commercial devices and under different configurations of those elements that may significantly hamper the battery lifetime.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4515
Author(s):  
Rinku Roy ◽  
Manjunatha Mahadevappa ◽  
Kianoush Nazarpour

Humans typically fixate on objects before moving their arm to grasp the object. Patients with ALS disorder can also select the object with their intact eye movement, but are unable to move their limb due to the loss of voluntary muscle control. Though several research works have already achieved success in generating the correct grasp type from their brain measurement, we are still searching for fine controll over an object with a grasp assistive device (orthosis/exoskeleton/robotic arm). Object orientation and object width are two important parameters for controlling the wrist angle and the grasp aperture of the assistive device to replicate a human-like stable grasp. Vision systems are already evolved to measure the geometrical attributes of the object to control the grasp with a prosthetic hand. However, most of the existing vision systems are integrated with electromyography and require some amount of voluntary muscle movement to control the vision system. Due to that reason, those systems are not beneficial for the users with brain-controlled assistive devices. Here, we implemented a vision system which can be controlled through the human gaze. We measured the vertical and horizontal electrooculogram signals and controlled the pan and tilt of a cap-mounted webcam to keep the object of interest in focus and at the centre of the picture. A simple ‘signature’ extraction procedure was also utilized to reduce the algorithmic complexity and system storage capacity. The developed device has been tested with ten healthy participants. We approximated the object orientation and the size of the object and determined an appropriate wrist orientation angle and the grasp aperture size within 22 ms. The combined accuracy exceeded 75%. The integration of the proposed system with the brain-controlled grasp assistive device and increasing the number of grasps can offer more natural manoeuvring in grasp for ALS patients.


2021 ◽  
Author(s):  
Jincheng Lu ◽  
Zixuan Ou ◽  
Ziyu Liu ◽  
Cheng Han ◽  
Wenbin Ye

2018 ◽  
Vol 2018 ◽  
pp. 1-20 ◽  
Author(s):  
Markus Bajones ◽  
David Fischinger ◽  
Astrid Weiss ◽  
Daniel Wolf ◽  
Markus Vincze ◽  
...  

We present the robot developed within the Hobbit project, a socially assistive service robot aiming at the challenge of enabling prolonged independent living of elderly people in their own homes. We present the second prototype (Hobbit PT2) in terms of hardware and functionality improvements following first user studies. Our main contribution lies within the description of all components developed within the Hobbit project, leading to autonomous operation of 371 days during field trials in Austria, Greece, and Sweden. In these field trials, we studied how 18 elderly users (aged 75 years and older) lived with the autonomously interacting service robot over multiple weeks. To the best of our knowledge, this is the first time a multifunctional, low-cost service robot equipped with a manipulator was studied and evaluated for several weeks under real-world conditions. We show that Hobbit’s adaptive approach towards the user increasingly eased the interaction between the users and Hobbit. We provide lessons learned regarding the need for adaptive behavior coordination, support during emergency situations, and clear communication of robotic actions and their consequences for fellow researchers who are developing an autonomous, low-cost service robot designed to interact with their users in domestic contexts. Our trials show the necessity to move out into actual user homes, as only there can we encounter issues such as misinterpretation of actions during unscripted human-robot interaction.


2015 ◽  
Vol 14 (3-4) ◽  
Author(s):  
K Sadesh ◽  
PV Mohram ◽  
S Udhayakumar

<p>A part feeder intakes identical parts of arbitrary orientation and provides output in uniform orientation. A flexible feeder is capable of handling parts of several sizes. The two important modules of a flexible part feeder are (i) identification of part (ii) adjustments to accommodate the incoming part. This paper aims at first module i.e. developing a low cost part identification system using two proximity sensors and thereby eliminating the use of costlier vision systems. The proposed part identification system using two capacitive type proximity sensors was effective in identifying the size of incoming parts and the efficiency of the system was around 84.6%.</p>


Sign in / Sign up

Export Citation Format

Share Document