Frameless deep brain stimulation using intraoperative O-arm technology

2011 ◽  
Vol 115 (2) ◽  
pp. 301-309 ◽  
Author(s):  
Adam P. Smith ◽  
Roy A. E. Bakay

Object Correct lead location in the desired target has been proven to be a strong influential factor for good clinical outcome in deep brain stimulation (DBS) surgery. Commonly, a surgeon's first reliable assessment of such location is made on postoperative imaging. While intraoperative CT (iCT) and intraoperative MR imaging have been previously described, the authors present a series of frameless DBS procedures using O-arm iCT. Methods Twelve consecutive patients with 15 leads underwent frameless DBS placement using electrophysiological testing and O-arm iCT. Initial target coordinates were made using standard indirect and direct assessment. Microelectrode recording (MER) with kinesthetic responses was performed, followed by microstimulation to evaluate the side-effect profile. Intraoperative 3D CT acquisitions obtained between each MER pass and after final lead placement were fused with the preoperative MR image to verify intended MER movements around the target area and to identify the final lead location. Tip coordinates from the initial plan, final intended target, and actual lead location on iCT were later compared with the lead location on postoperative MR imaging, and euclidean distances were calculated. The amount of radiation exposure during each procedure was calculated and compared with the estimated radiation exposure if iCT was not performed. Results The mean euclidean distances between the coordinates for the initial plan, final intended target, and actual lead on iCT compared with the lead coordinates on postoperative MR imaging were 3.04 ± 1.45 mm (p = 0.0001), 2.62 ± 1.50 mm (p = 0.0001), and 1.52 ± 1.78 mm (p = 0.0052), respectively. The authors obtained good merging error during image fusion, and postoperative brain shift was minimal. The actual radiation exposure from iCT was invariably less than estimates of exposure using standard lateral fluoroscopy and anteroposterior radiographs (p < 0.0001). Conclusions O-arm iCT may be useful in frameless DBS surgery to approximate microelectrode or lead locations intraoperatively. Intraoperative CT, however, may not replace fundamental DBS surgical techniques such as electrophysiological testing in movement disorder surgery. Despite the lack of evidence for brain shift from the procedure, iCT-measured coordinates were statistically different from those obtained postoperatively, probably indicating image merging inaccuracy and the difficulties in accurately denoting lead location. Therefore, electrophysiological testing may truly be the only means of precisely knowing the location in 3D space intraoperatively. While iCT may provide clues to electrode or lead location during the procedure, its true utility may be in DBS procedures targeting areas where electrophysiology is less useful. The use of iCT appears to reduce radiation exposure compared with the authors' traditional frameless technique.

2011 ◽  
Vol 115 (4) ◽  
pp. 852-857 ◽  
Author(s):  
Olivia O. Huston ◽  
Robert E. Watson ◽  
Matt A. Bernstein ◽  
Kiaran P. McGee ◽  
S. Matt Stead ◽  
...  

Object Deep brain stimulation (DBS) is an established neurosurgical technique used to treat a variety of neurological disorders, including Parkinson disease, essential tremor, dystonia, epilepsy, depression, and obsessive-compulsive disorder. This study reports on the use of intraoperative MR imaging during DBS surgery to evaluate acute hemorrhage, intracranial air, brain shift, and accuracy of lead placement. Methods During a 46-month period, 143 patients underwent 152 DBS surgeries including 289 lead placements utilizing intraoperative 1.5-T MR imaging. Imaging was supervised by an MR imaging physicist to maintain the specific absorption rate below the required level of 0.1 W/kg and always included T1 magnetization-prepared rapid gradient echo and T2* gradient echo sequences with selected use of T2 fluid attenuated inversion recovery (FLAIR) and T2 fast spin echo (FSE). Retrospective review of the intraoperative MR imaging examinations was performed to quantify the amount of hemorrhage and the amount of air introduced during the DBS surgery. Results Intraoperative MR imaging revealed 5 subdural hematomas, 3 subarachnoid hemorrhages, and 1 intraparenchymal hemorrhage in 9 of the 143 patients. Only 1 patient experiencing a subarachnoid hemorrhage developed clinically apparent symptoms, which included transient severe headache and mild confusion. Brain shift due to intracranial air was identified in 144 separate instances. Conclusions Intraoperative MR imaging can be safely performed and may assist in demonstrating acute changes involving intracranial hemorrhage and air during DBS surgery. These findings are rarely clinically significant and typically resolve prior to follow-up imaging. Selective use of T2 FLAIR and T2 FSE imaging can confirm the presence of hemorrhage or air and preclude the need for CT examinations.


2007 ◽  
Vol 107 (5) ◽  
pp. 989-997 ◽  
Author(s):  
Yasushi Miyagi ◽  
Fumio Shima ◽  
Tomio Sasaki

Object The goal of this study was to focus on the tendency of brain shift during stereotactic neurosurgery and the shift's impact on the unilateral and bilateral implantation of electrodes for deep brain stimulation (DBS). Methods Eight unilateral and 10 bilateral DBS electrodes at 10 nuclei ventrales intermedii and 18 subthalamic nuclei were implanted in patients at Kaizuka Hospital with the aid of magnetic resonance (MR) imaging–guided and microelectrode-guided methods. Brain shift was assessed as changes in the 3D coordinates of the anterior and posterior commissures (AC and PC) with MR images before and immediately after the implantation surgery. The positions of the implanted electrodes, based on the midcommissural point and AC–PC line, were measured both on x-ray films (virtual position) during surgery and the postoperative MR images (actual position) obtained on the 7th day postoperatively. Results Contralateral and posterior shift of the AC and PC were the characteristics of unilateral and bilateral procedures, respectively. The authors suggest the following. 1) The first unilateral procedure elicits a unilateral air invasion, resulting in a contralateral brain shift. 2) During the second procedure in the bilateral surgery, the contralateral shift is reset to the midline and, at the same time, the anteroposterior support by the contralateral hemisphere against gravity is lost due to a bilateral air invasion, resulting in a significant posterior (caudal) shift. Conclusions To note the tendency of the brain to shift is very important for accurate implantation of a DBS electrode or high frequency thermocoagulation, as well as for the prediction of therapeutic and adverse effects of stereotactic surgery.


2019 ◽  
Vol 130 (6) ◽  
pp. 1841-1846 ◽  
Author(s):  
Leonardo A. Frizon ◽  
Sean J. Nagel ◽  
Francis J. May ◽  
Jianning Shao ◽  
Andres L. Maldonado-Naranjo ◽  
...  

OBJECTIVEThe number of patients who benefit from deep brain stimulation (DBS) for Parkinson’s disease (PD) has increased significantly since the therapy was first approved by the FDA. Suboptimal outcomes, infection, or device failure are risks of the procedure and may require lead removal or repositioning. The authors present here the results of their series of revision and reimplantation surgeries.METHODSThe data were reviewed from all DBS intracranial lead removals, revisions, or reimplantations among patients with PD over a 6-year period at the authors’ institution. The indications for these procedures were categorized as infection, suboptimal outcome, and device failure. Motor outcomes as well as lead location were analyzed before removal and after reimplant or revision.RESULTSThe final sample included 25 patients who underwent 34 lead removals. Thirteen patients had 18 leads reimplanted after removal. There was significant improvement in the motor scores after revision surgery among the patients who had the lead revised for a suboptimal outcome (p = 0.025). The mean vector distance of the new lead location compared to the previous location was 2.16 mm (SD 1.17), measured on an axial plane 3.5 mm below the anterior commissure–posterior commissure line. When these leads were analyzed by subgroup, the mean distance was 1.67 mm (SD 0.83 mm) among patients treated for infection and 2.73 mm (SD 1.31 mm) for those with suboptimal outcomes.CONCLUSIONSPatients with PD who undergo reimplantation surgery due to suboptimal outcome may experience significant benefits. Reimplantation after surgical infection seems feasible and overall safe.


2019 ◽  
Vol 132 ◽  
pp. e487-e495
Author(s):  
Ryan B. Kochanski ◽  
Sander Bus ◽  
Bledi Brahimaj ◽  
Alireza Borghei ◽  
Kristen L. Kraimer ◽  
...  

2016 ◽  
Vol 124 (1) ◽  
pp. 62-69 ◽  
Author(s):  
Zhiqiang Cui ◽  
Longsheng Pan ◽  
Huifang Song ◽  
Xin Xu ◽  
Bainan Xu ◽  
...  

OBJECT The degree of clinical improvement achieved by deep brain stimulation (DBS) is largely dependent on the accuracy of lead placement. This study reports on the evaluation of intraoperative MRI (iMRI) for adjusting deviated electrodes to the accurate anatomical position during DBS surgery and acute intracranial changes. METHODS Two hundred and six DBS electrodes were implanted in the subthalamic nucleus (STN) in 110 patients with Parkinson disease. All patients underwent iMRI after implantation to define the accuracy of lead placement. Fifty-six DBS electrode positions in 35 patients deviated from the center of the STN, according to the result of the initial postplacement iMRI scans. Thus, we adjusted the electrode positions for placement in the center of the STN and verified this by means of second or third iMRI scans. Recording was performed in adjusted parameters in the x-, y-, and z-axes. RESULTS Fifty-six (27%) of 206 DBS electrodes were adjusted as guided by iMRI. Electrode position was adjusted on the basis of iMRI 62 times. The sum of target coordinate adjustment was −0.5 mm in the x-axis, −4 mm in the y-axis, and 15.5 mm in the z-axis; the total of distance adjustment was 74.5 mm in the x-axis, 88 mm in the y-axis, and 42.5 mm in the z-axis. After adjustment with the help of iMRI, all electrodes were located in the center of the STN. Intraoperative MRI revealed 2 intraparenchymal hemorrhages in 2 patients, brain shift in all patients, and leads penetrating the lateral ventricle in 3 patients. CONCLUSIONS The iMRI technique can guide surgeons as they adjust deviated electrodes to improve the accuracy of implanting the electrodes into the correct anatomical position. The iMRI technique can also immediately demonstrate acute changes such as hemorrhage and brain shift during DBS surgery.


2015 ◽  
Vol 18 (5) ◽  
pp. 341-348 ◽  
Author(s):  
Lia Lucas-Neto ◽  
Sofia Reimão ◽  
Edson Oliveira ◽  
Alexandre Rainha-Campos ◽  
João Sousa ◽  
...  