Lateral Load Capacity and Passive Resistance of Full-Scale Pile Group and Cap

Author(s):  
Kyle M. Rollins ◽  
Andrew E. Sparks ◽  
Kris T. Peterson

Static and dynamic (statnamic) lateral load tests were performed on a full-scale 3 × 3 pile group driven in saturated low-plasticity silts and clays. The 324-mm outside diameter steel pipe piles were attached to a reinforced concrete pile cap (2.74 m square in plan and 1.21 m high), which created an essentially fixed-head end constraint. A gravel backfill was compacted in place on the back side of the cap. Lateral resistance was therefore provided by pile-soil-pile interaction as well as by base friction and passive pressure on the cap. In this case, passive resistance contributed about 40 percent of the measured static capacity. The measured resistance was compared with that computed by several techniques. The log-spiral method provided the best agreement with measured resistance. Estimates of passive pressure computed using the Rankine or GROUP p-y curve methods significantly underestimated the resistance, whereas the Coulomb method overestimated resistance. The wall movement required to fully mobilize passive resistance in the dense gravel backfill was approximately 0.06 times the wall height, which is in good agreement with design recommendations. The p-multipliers developed for the free-head pile group provided reasonable estimates of the pile-soil-pile resistance for the fixed-head pile group. Default p-multipliers in the program GROUP led to a 35 percent overestimate of pile capacity. Overall dynamic resistance was typically 100 to 125 percent higher than static; however, dynamic passive pressure resistance was over 200 percent higher than static.

2018 ◽  
Vol 1 (2) ◽  
pp. 1-12 ◽  
Author(s):  
Hafiz Muhammad Rashid ◽  
Shaukat Ali Khan ◽  
Rao Arsalan Khushnood ◽  
Junaid Ahmad

This article describes Dhajji Dewari which is a non-engineered traditional construction method mostly used in the northern parts of Pakistan. This method consists of a timber frame filled with the stones in a mud slurry. This article is aimed to assess the effects of different infills on the lateral load capacity of Dhajji Dewari. For this purpose, three full scale Dhajji Dewari panels were constructed and unidirectional in-plane lateral load was applied. One panel was without infill, two other panels with different type of infills. Results of the experimentation showed that the infill presence effects the lateral load resisting performance of the Dhajji Dewari.


1980 ◽  
Vol 106 (8) ◽  
pp. 954-956
Author(s):  
Jai B. Kim ◽  
Robert J. Brungraber ◽  
Lakshman P. Singh
Keyword(s):  
Pile Cap ◽  

Author(s):  
Kyle M. Rollins ◽  
Kris T. Peterson ◽  
Thomas J. Weaver

1979 ◽  
Vol 105 (5) ◽  
pp. 643-653
Author(s):  
Jai B. Kim ◽  
Robert J. Brungraber ◽  
Lakshman P. Singh
Keyword(s):  
Pile Cap ◽  

2016 ◽  
Vol 845 ◽  
pp. 94-99
Author(s):  
Noegroho Djarwanti ◽  
Raden Harya Dananjaya ◽  
Fauziah Prasetyaningrum

In the construction projects, a pile group foundation is often utilized. The group of bored piles is usually installed relatively close to each other and joined at the top by a pile cap to hold up the loads. In other hand, a fast estimation of the groups of piles capacities are needed in the preliminary design and in other conditions of projects, such as a supervisor of projects want to estimate the capacities of the group of piles. The purpose of this research is to study the correlations of groups of piles efficiencies with the number of piles and to compare the groups of piles capacities with the single piles capacities. Furthermore, this study is aimed to make a fast estimation of groups of piles capacities using proposed graphical method.The piles efficiencies are calculated using several methods, such as Simplified Analysis, Converse-Labare [1][2], Los Angeles Group, Seiler - Keeney, Das, and Sayed - Baker. In order to calculate the groups of piles capacities, the capacities of single piles are needed. The singles piles capacities are taken from graphical method proposed by Djarwanti et al. (2015a and 2015b). Three graphical methods utilized are derived from the Briaud et al. (1985) , Reese and Wright (1977), and Reese O’Neill method. Moreover, the proposed graphical method is applied in the case study. The case study takes palace in Graha Indoland Condotel Inside Yogyakarta Construction Project.The pile efficiency graph is recommended for this research since the value of pile efficiency could be easily taken. The value of pile efficiency for Graha Indoland Condotel Inside using Simplified Analysis, Converse - Labare, Los Angeles Group, Seiler – Keeney, Das, and Sayed – Baker are 1,75; 0,89; 0,94; 0,99; 4,00; 1,56 respectively. Meanwhile the value of pile group capacity with the value of pile group efficiency more than 1, showed that the pile group capacity based on the efficiency is bigger than the one based on single down pattern.


Sign in / Sign up

Export Citation Format

Share Document