Analyses and estimation of insulation material release in E.ON-PWR under loss of coolant conditions

Kerntechnik ◽  
2011 ◽  
Vol 76 (1) ◽  
pp. 54-57
Author(s):  
R. Koring
Author(s):  
T. Gocht ◽  
W. Kästner ◽  
A. Kratzsch ◽  
M. Strasser

In case of an accident the safe heat removal from the reactor core with the installed emergency core cooling system (ECCS) is one of the main features in reactor safety. During a loss-of-coolant accident (LOCA) the release of insulation material fragments in the reactor containment can lead to malfunctions of ECCS. Therefore, the retention of particles by strainers or filtering systems in the ECCS is one of the major tasks. The aim of the presented experimental investigations was the evaluation of a filtering system for the retention of fiber-shaped particles in a fluid flow. The filtering system consists of a filter case with a special lamellar filter unit. The tests were carried out at a test facility with filtering units of different mesh sizes. Insulation material (mineral rock wool) was fragmented to fiber-shaped particles. To simulate the distribution of particle concentration at real plants with large volumes the material was divided into single portions and introduced into the loop with a defined time interval. Material was transported to the filter by the fluid and agglomerated there. The assessment of functionality of the filtering system was made by differential pressure between inlet and outlet of the filtering system and by mass of penetrated particles. It can be concluded that for the tested filtering system no penetration of insulation particles occurred.


Kerntechnik ◽  
2011 ◽  
Vol 76 (1) ◽  
pp. 58-65
Author(s):  
J. Huber ◽  
M. Becker ◽  
J. Unterrainer ◽  
T. Thiele ◽  
C. Reichel ◽  
...  

Author(s):  
Alexander Kratzsch ◽  
Wolfgang Ka¨stner ◽  
Rainer Hampel

The paper deals with the calculation of differential pressure on sieves after a loss of coolant accident (LOCA) in boiling water reactors. One of the main features in reactor safety research is the safe heat dissipation from the reactor core and the reactor containment of light-water reactors. In the case of loss of coolant accident the possibility of the entry of insulation material into the reactor containment and the building sump of the reactor containment and into the associated systems to the residual heat exhaust is a serious problem. This can lead to a handicap of the system functions. To ensure the residual heat exhaust it is necessary the emergency cooling systems to put in operation which transport the water from the sump to the condensation chamber and directly to the reactor pressure vessel. A high allocation of the sieves with fractionated insulation material, in the sump can lead to a blockage of the sieves, inadmissibly increase of differential pressure, build-up at the sieves and to malfunctioning pumps. Hence, the scaling and retention of fractionated insulation material in the building sump of the reactor containment must be estimated. This allows the potential plant status in case of incidents to be assessed. The differential pressure is the essential parameter for the assessment of allocation of the sieves.


Author(s):  
Thomas Ho¨hne ◽  
Alexander Grahn ◽  
So¨ren Kliem ◽  
Ulrich Rohde ◽  
Frank-Peter Weiss

In 1992, strainers on the suction side of the ECCS pumps in Barseba¨ck NPP Unit 2 became partially clogged with mineral wool because after a safety valve opened the steam impinged on thermally-insulated equipment and released mineral wool. This event pointed out that strainer clogging is an issue in the course of a loss-of-coolant accident. Modifications of the insulation material, the strainer area and mesh size were carried out in most of the German NPPs. Moreover, back flushing procedures to remove the mineral wool from the strainers and differential pressure measurements were implemented to assure the performance of emergency core cooling during the containment sump recirculation mode. Nevertheless, it cannot be completely ruled out, that a limited amount of small fractions of the insulation material is transported into the RPV. During a postulated cold leg LOCA with hot leg ECC injection, the fibers enter the upper plenum and can accumulate at the fuel element spacer grids, preferably at the uppermost grid level. This effect might affect the ECC flow into the core and could result in degradation of core cooling. It was the aim of the numerical simulations presented to study where and how many mineral wool fibers are deposited at the upper spacer grid. The 3D, time dependent, multi-phase flow problem was modelled applying the CFD code ANSYS CFX. The CFD calculation does not yet include steam production in the core and also does not include re-suspension of the insulation material during reverse flow. This will certainly further improve the coolability of the core. The spacer grids were modelled as a strainer, which completely retains all the insulation material reaching the uppermost spacer level. There, the accumulation of the insulation material gives rise to the formation of a compressible fibrous cake, the permeability of which to the coolant flow is calculated in terms of the local amount of deposited material and the local value of the superficial liquid velocity. Before the switch over of the ECC injection from the flooding mode to the sump mode, the coolant circulates in an inner convection loop in the core extending from the lower plenum to the upper plenum. The CFD simulations have shown that after starting the sump mode, the ECC water injected through the hot legs flows down into the core at so-called “breakthrough channels” located at the outer core region where the downward leg of the convection roll had established. The hotter, lighter coolant rises in the centre of the core. As a consequence, the insulation material is preferably deposited at the uppermost spacer grids positioned in the breakthrough zones. This means that the fibers are not uniformly deposited over the core cross section. When the inner recirculation stops later in the transient, insulation material can also be collected in other regions of the core. Nevertheless, with a total of 2.7 kg fiber material deposited at the uppermost spacer level, the pressure drop over the fiber cake is not higher than 8 kPa and all the ECC water could still enter the core.


Kerntechnik ◽  
2011 ◽  
Vol 76 (1) ◽  
pp. 8-14 ◽  
Author(s):  
A. Bröcker ◽  
W. Pointner
Keyword(s):  