Methods and Sources of Data Used to Develop Selected Water-Quality Indicators for Streams and Ground Water for the 2007 Edition of The State of the Nation's Ecosystems Report with Comparisons to the 2002 Edition

2008 ◽  
Author(s):  
John T. Wilson ◽  
Nancy T. Baker ◽  
Michael J. Moran ◽  
Charles G. Crawford ◽  
Lisa H. Nowell ◽  
...  
2021 ◽  
Vol 13 (14) ◽  
pp. 8029
Author(s):  
Enrique Cervantes-Astorga ◽  
Oscar Aguilar-Juárez ◽  
Danay Carrillo-Nieves ◽  
Misael Sebastián Gradilla-Hernández

Inadequate management practices for solid waste and wastewater are some of the main causes of eutrophication globally, especially in regions where intensive livestock, agricultural, and industrial activities are coupled with inexistent or ineffective waste and wastewater treatment infrastructure. In this study, a methodological approach is presented to spatially assess the trophic state of large territories based on public water quality databases. The trophic state index (TSI) includes total nitrogen, total phosphorus, chlorophyll A, chemical oxygen demand, and Secchi disk depth values as water quality indicators. A geographical information system (GIS) was used to manage the spatiotemporal attributes of the water quality data, in addition to spatially displaying the results of TSI calculations. As a case study, this methodological approach was applied to determine the critical regions for mitigating eutrophication in the state of Jalisco, Mexico. Although a decreasing trend was observed for the TSI values over time for most subbasins (2012–2019), a tendency for extreme hypereutrophication was observed in some regions, such as the Guadalajara metropolitan area and the Altos region, which are of high economic relevance at the state level. A correlation analysis was performed between the TSI parameters and rainfall measurements for all subbasins under analysis, which suggested a tendency for nutrient wash-off during the rainy seasons for most subbasins; however, further research is needed to quantify the real impacts of rainfall by including other variables such as elevation and slope. The relationships between the water quality indicators and land cover were also explored. The GIS methodology proposed in this study can be used to spatially assess the trophic state of large regions over time, taking advantage of available water quality databases. This will enable the efficient development and implementation of public policies to assess and mitigate the eutrophication of water sources, as well as the efficient allocation of resources for critical regions. Further studies should focus on applying integrated approaches combining on-site monitoring data, remote sensing data, and machine learning algorithms to spatially evaluate the trophic state of territories.


TAPPI Journal ◽  
2009 ◽  
Vol 8 (3) ◽  
pp. 14-20 ◽  
Author(s):  
YUAN-SHING PERNG ◽  
EUGENE I-CHEN WANG ◽  
SHIH-TSUNG YU ◽  
AN-YI CHANG

Trends toward closure of white water recirculation loops in papermaking often lead to a need for system modifications. We conducted a pilot-scale study using pulsed electrocoagulation technology to treat the effluent of an old corrugated containerboard (OCC)-based paper mill in order to evaluate its treatment performance. The operating variables were a current density of 0–240 A/m2, a hydraulic retention time (HRT) of 8–16 min, and a coagulant (anionic polyacrylamide) dosage of 0–22 mg/L. Water quality indicators investigated were electrical con-ductivity, suspended solids (SS), chemical oxygen demand (COD), and true color. The results were encouraging. Under the operating conditions without coagulant addition, the highest removals for conductivity, SS, COD, and true color were 39.8%, 85.7%, 70.5%, and 97.1%, respectively (with an HRT of 16 min). The use of a coagulant enhanced the removal of both conductivity and COD. With an optimal dosage of 20 mg/L and a shortened HRT of 10 min, the highest removal achieved for the four water quality indicators were 37.7%, 88.7%, 74.2%, and 91.7%, respectively. The water qualities thus attained should be adequate to allow reuse of a substantial portion of the treated effluent as process water makeup in papermaking.


2018 ◽  
Vol 69 (10) ◽  
pp. 2940-2952 ◽  
Author(s):  
Martina Zelenakova ◽  
Pavol Purcz ◽  
Radu Daniel Pintilii ◽  
Peter Blistan ◽  
Petr Hlustik ◽  
...  

Evaluating trends in water quality indicators is a crucial issue in integrated water resource management in any country. In this study eight chemical and physical water quality indicators were analysed in seven river profiles in the River Laborec in eastern Slovakia. The analysed water quality parameters were biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), pH, temperature (t), ammonium nitrogen (NH4+-N), nitrite nitrogen (NO2--N), nitrate nitrogen (NO3--N), and total phosphorus (TP). Data from the monitored indicators were provided by the Ko�ice branch of the Slovakian Water Management Company, over a period of 15 years from 1999 to 2013. Mann�Kendall non-parametric statistical test was used for the trend analysis. Biochemical and chemical oxygen demand, ammonium and nitrite nitrogen content exhibit decreasing trends in the River Laborec. Decreasing agricultural activity in the area has had a significant impact on the trends in these parameters. However, NO2--N was the significant parameter of water quality because it mostly exceeds the limit value set in Slovak legislation, Regulation No. 269/2010 Coll. In addition, water temperature revealed an increasing trend which could be caused by global increase in air temperature. These results indicate that human activity significantly impacts the water quality.


Hydrology ◽  
2021 ◽  
Vol 8 (2) ◽  
pp. 86
Author(s):  
Angeliki Mentzafou ◽  
George Varlas ◽  
Anastasios Papadopoulos ◽  
Georgios Poulis ◽  
Elias Dimitriou

Water resources, especially riverine ecosystems, are globally under qualitative and quantitative degradation due to human-imposed pressures. High-temporal-resolution data obtained from automatic stations can provide insights into the processes that link catchment hydrology and streamwater chemistry. The scope of this paper was to investigate the statistical behavior of high-frequency measurements at sites with known hydromorphological and pollution pressures. For this purpose, hourly time series of water levels and key water quality indicators (temperature, electric conductivity, and dissolved oxygen concentrations) collected from four automatic monitoring stations under different hydromorphological conditions and pollution pressures were statistically elaborated. Based on the results, the hydromorphological conditions and pollution pressures of each station were confirmed to be reflected in the results of the statistical analysis performed. It was proven that the comparative use of the statistics and patterns of the water level and quality high-frequency time series could be used in the interpretation of the current site status as well as allowing the detection of possible changes. This approach can be used as a tool for the definition of thresholds, and will contribute to the design of management and restoration measures for the most impacted areas.


2021 ◽  
Vol 11 (5) ◽  
Author(s):  
Durai Ganesh ◽  
G. Senthilkumar ◽  
P. Eswaran ◽  
M. Balakrishnan ◽  
S. N. Bramha ◽  
...  

AbstractUranium concentration in the ground water samples from the district of Tiruvannamalai, Tamil Nadu, was measured using an LED fluorimeter. All the samples were qualified as potable water from the radiological perspective. Though some samples showed mild chemical toxicity, they are still safe for ingestion. Different risk coefficients were calculated, and they were compared with recommended safety limits specified by various agencies. Software tools such as QGIS 15, GraphPad Prism 8 and Surfer 15 were employed for developing maps and plots.


Sign in / Sign up

Export Citation Format

Share Document