scholarly journals EXPERIMENTAL STUDY ON PUNCHING SHEAR FAILURE OF FLAT SLAB STRUCTURE WITH STEEL COLUMN AND STEEL CAPITAL IN RC SLAB

2020 ◽  
Vol 85 (768) ◽  
pp. 299-309
Author(s):  
Yasuhiko YAMASHITA ◽  
Yoshihiro OHTA
Author(s):  
Shinya Nakaue ◽  
Yasushi Nishimura

To improve the bearing failure behavior of the exterior steel beam-reinforced concrete column joints composed of reinforced concrete columns, joint details using steel column was proposed. Steel column was attached to the lower flanges at right angles to the steel flange. The objective of this study is to clarify the effectiveness of proposed joint details experimentally and theoretically. To clarify the influence of steel column on the bearing failure of the joint, seven T-shaped subassemblages were tested under reversed cyclic loading. All specimens had the same cross sections of the steel beam. The experimental variables were the embedded length of the steel column, whether there is the end plate at the tip of the embedded steel column, and, the arrangement of transverse reinforcement ratio surrounding the steel column. The following remarks can be drawn from the test results. 1) In case of the specimen with a short embedded length of the steel column, the punching shear failure on the upper surface of the steel beam flange was remarkable when the maximum strength was reached. However, in the specimen with long embedded length of steel column, it was not observed the punching shear failure. 2) The maximum strength increased with the embedded length of the steel column. Further, the maximum strength of the specimen with the embedded length of three times of the steel column depths is subjected to bending yield strength of the steel column. 3) It was shown that the transverse reinforcement to surround the steel column and the end plate were necessary to improve the bearing failure of the joint. 


2004 ◽  
Vol 10 (4) ◽  
pp. 311-316 ◽  
Author(s):  
Povilas Vainiunas ◽  
Vladimiras Popovas ◽  
Andrej Jarmolajev

2019 ◽  
Vol 292 ◽  
pp. 146-152
Author(s):  
Amr Abdelkhalik ◽  
Tamer Elafandy ◽  
Amr Abdelrahman ◽  
Alaa Sherif

Reinforced concrete flat slab-column structures are widely used because of their practicality. However, this type of structures can be subjected to punching-shear failure within the slab-column connections. Without shear reinforcement, the slab-column connection can undergo brittle punching failure, especially when the structure is subjected to lateral loading in seismic zones. This research is a part of an extensive investigation about the punching shear behaviour of interior RC slab-column connections under seismic loading. The main objective is to discuss the effect of the gravity shear level on the punching shear behaviour[1].The current paper represents only the results of the first four tested specimens without shear reinforcement. The first specimen was tested subjected to vertical gravity load only without cyclic loading while the other three specimens were tested under different vertical loads V which was kept constant during testing in addition to a reversed displacement controlled cyclic loading which was increased up to punching shear failure. The gravity load V was chosen as 0.4, 0.6 and 0.8 V0 respectively, where V0 is the vertical load causing punching shear failure according to ACI318-14[2]. All tested specimens have the same slab dimensions of 2000x2000mm, slab thickness 200mm, flexural reinforcement ratio of 1.62% and the same column dimensions 250mm x 250mm. Finally, the experimental results are analyzed and compared to international codes such as American Code ACI318-14 and Euro Code EC2-2004[3]. In light of these results, some preliminary conclusions are presented.


Author(s):  
Hamid Abdulmahdi Faris ◽  
Lubna Mohammed Abd

The "flat slab" is a reinforced concrete slab bolstered, by a number of columns. Punching, shear is a category for collapse for reinforced concrete slabs exposed to great confined forces. In "flat slab" constructions the shear failure happens, at column bolster joints. To avoid this, collapse two methods are used, first method is increasing the column dimensions and, the other is to use drop panel if the first method leads to uneconomical, design. Two examples are used to find the effect, of column dimensions, increase on the punching shear failure of "flat slab". The first example, is a "flat slab" of span (5 by 5) m and the other is of span (6 by 6) m. The column which examined is the interior, edge and corner columns, and the interior column is the most dangerous case. It is concluded that, the increase of column dimensions are lead to avoid of punching shear failure in "flat slab" and the drop panel is enlarge the area of the critical shear perimeter and this avoiding punching shear failure.


2008 ◽  
Vol 385-387 ◽  
pp. 857-860
Author(s):  
Hyun Ki Choi ◽  
J.S. Kim ◽  
E.S. Jin ◽  
Chang Sik Choi

This research is an experimental study on full-scale interior slab-column connections of flat-plate. Three types of shear reinforcements were proposed to prevent brittle punching shear failure that could result in collapse of whole flat plate structures. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with the reinforcements was tested. The dimension of the slabs was 2620*2725*180mm and the specimens had a 600*800mm square column at the center of the slabs. The slabs were tested up to failure using monotonic vertical shear forces. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slab-column connections.


2021 ◽  
Vol 16 (1) ◽  
pp. 52-57
Author(s):  
Petra Bujňáková ◽  
Jakub Mečár

AbstractSeveral types of punching shear reinforcements are available for increase of the maximum resistance against punching shear failure of flat slabs. Conventional punching shear reinforcement in form of stirrups or double headed studs are in use for decades. They are well known due to their simplicity and good performance. A new type of punching reinforcement has been developed for the case, where the flat slab exposed to extreme load and resistance of conventional type of punching shear reinforcement is not sufficient. Another designs point out that new construction system can reduce the amount of CO2. This paper presents some results of parametric study focused on design of the flat slab using different types of punching shear reinforcement and considering the concrete consumption.


2013 ◽  
Vol 4 (4) ◽  
pp. 259-280 ◽  
Author(s):  
Mehrafarid Ghoreishi ◽  
Ashutosh Bagchi ◽  
Mohamed Sultan

There are a number of benefits associated with two-way concrete flat slab construction for office buildings, parking garages and apartments - for example, reduced formwork, prompt erection, flexibility of partitions, and minimal increase in story heights. However, concrete flat slabs could be quite vulnerable to punching shear failure in the event of a fire. The objective of the present article is to provide a state of the art review of the existing research and the issues associated with concrete flat slabs in fire and elevated temperature. There are a number of experimental and analytical studies on the punching shear behavior of concrete flat slabs in ambient conditions, available in the literature. Based on these studies, it is found that punching shear capacity in ambient condition is affected by many factors, which may not remain constant during a fire exposure. Only a limited number of studies on concrete flat slabs for punching shear failure in fire are available. This paper reviews the available experimental and analytical studies, standards and codes to address the research gap in estimating of punching shear strength of concrete flat slab-column connections without shear reinforcement.


2018 ◽  
Vol 7 (2.20) ◽  
pp. 321
Author(s):  
N Girish ◽  
N Lingeshwaran

Punching shear failure is a brittle failure and it is one of the most important types of failure to be considered while designing a reinforced concrete flat slab. This paper aims to study the performance of reinforced concrete flat slabs equipped with different punching shear reinforcement parameters. Three flat slab specimens were cast where two specimens contain punching shear reinforcement in the form of shear stirrups and structural shearbands. The test specimens have length and width of 1000mm and thickness of 185mm for the slabs. The slabs are connected to a column at the center with length and breadth of 300mm and a depth of 700mm. The test specimens were supported by steel plates with length and breadth of 150mm and a thickness of 25mm at the four corners of the slab. The test specimens are loaded on the column face at the top. The deflection, strain and crack pattern were observed and recorded.   