scholarly journals Finite Element Simulative Analysis of Concrete Arch Dam Structure

Author(s):  
Dongyu Ji ◽  
Weixing Chen
2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Zhuoyan Chen ◽  
Dongjian Zheng ◽  
Jiqiong Li ◽  
Xin Wu ◽  
Jianchun Qiu

Temperature is one of the factors affecting the safety operation of concrete arch dams. To accurately reconstruct the temperature field of the concrete arch dam online based on the temperature data of several typical dam sections, this paper proposes the AdaBoost-ANN algorithm. The algorithm uses artificial neural network (ANN) to establish a training set of the measured temperature data and the temperature field of the concrete arch dam obtained by the three-dimensional finite element model; these trained artificial neural networks are used as weak classifiers of the AdaBoost algorithm. Then, the AdaBoost-ANN algorithm is used to establish the mapping relationship between the measured temperature data and the temperature field, and the online reconstruction of the temperature field of the concrete arch dam is realized. The case study shows that the temperature field of the concrete arch dam can be accurately established by AdaBoost-ANN algorithm based on limited temperature observation data. The algorithm is more time-saving and labor-saving than the finite element method and is convenient for online reconstruction of the temperature field and assessment of the safety status of the concrete arch dam.


2014 ◽  
Vol 1061-1062 ◽  
pp. 829-832
Author(s):  
Jia Long He ◽  
Yu Han Guo ◽  
Xi Zhu

The study on the calculation of the security of high concrete arch dam based on the finite element method will be studied and analyzed in this paper. For high concrete arch dam deformation and stability under normal water level and maximum flood level will be calculated, and the stress of each section of the dam and batholith around will be checked and analyzed, then this paper will come to the dam security conclusion finally.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Vahid Lotfi ◽  
Ali Lotfi

Purpose Subsequently, the response of idealized Morrow Point arch dam is studied due to stream, vertical and cross-stream ground motions for reservoir bottom/sidewalls conditions of both fully reflective and absorptive. For each combination, different orders of Hagstrom–Warburton (HW) condition are evaluated from accuracy point of view by comparing them against exact solutions. It should be emphasized that normalized length of reservoir near-field region is taken as a very low value of L/H = 0.2 during this process which makes it a very challenging test for any kind of truncation boundary condition. Design/methodology/approach In present study, dynamic analysis of concrete arch dam-reservoir systems is formulated by FE-(FE-TE) approach [i.e. finite element-(finite element-truncation element)]. In this technique, dam and reservoir are discretized by solid and fluid finite elements. Moreover, the HW high-order condition imposed at the reservoir truncation boundary. This task is formulated by employing a truncation element at that boundary. It is emphasized that reservoir far-field is excluded from the discretized model. The formulation is initially explained in details. Findings The trend in gaining accuracy with increase in order of HW condition were basically the same for all three types of excitations under both full reflective and absorptive reservoir bottom/sidewalls conditions. The only exception was for cross-stream excitation response which was showing less accurate results near the first major peak for moderate orders of HW (e.g. O3-2) in comparison to what was observed for responses due to symmetric excitations (stream and vertical). This is mainly attributed to the selection of evanescent-type parameters of HW condition which is based on the first symmetric mode of reservoir. However, it is noted that error diminishes even for cross-stream excitation as order increases. High orders of HW condition, such as O5-5 considered herein, generate highly accurate responses for all three possible excitations under both types of full reflective and absorptive reservoir bottom/sidewalls conditions. It is such that responses are hardly distinguishable from corresponding exact responses. This reveals that proposed FE-(FE-TE) analysis technique based on HW condition is quite successful, and one may fully rely on that for accurate and efficient analysis of concrete arch dam-reservoir systems. Originality/value Dynamic analysis of concrete arch dam-reservoir system is formulated by new method. HW high-order condition is applied for a very low and challenging reservoir length. Different orders are evaluated against exact solution with excellent agreement. Generalized matrices of truncation element are derived for FEM programmers. The method is discussed for all types of excitation and reservoir base conditions.


Sign in / Sign up