Strengthening of the Frame Structure at the Timisoreana Brewery, Romania

Author(s):  
Corneliu Bob ◽  
Sorin Dan ◽  
Catalin Badea ◽  
Aurelian Gruin ◽  
Liana Iures

<p>Many structures built in Romania before 1970 were designed for gravity loads with inadequate lateral load resistance because earlier codes specified lower levels of seismic loads. Some of these structures are still in service beyond their design life. Also, some deterioration was observed in existing structures due to the actions of different hazard factors. This paper presents the case study of a brewery with reinforced concrete framed structure of five storeys and a tower of nine storeys, which has been assessed and strengthened. The brewery and the tower were built in 1961 and an extension in 1971. An assessment performed in 1999 showed up local damages at slabs, main girders, secondary beams, and columns; concrete carbonation; concrete cover spalled over a large surface; complete corrosion of many stirrups and deep corrosion of main reinforcement; and some broken reinforcement. Such damage was caused by salt solution, CO2, relative humidity RH 80%, and temperatures over 40◦C. Also, inadequate longitudinal reinforcement was deduced≈ from the structural analysis. The initial design, done in 1960, was according to the Romanian codes of that time with provisions at low seismic actions. The structural system weakness is due to present-day high seismic actions. The rehabilitation of the reinforced concrete structure was performed by jacketing with reinforced concrete for the main and secondary beams and columns. In 2003, due to continuous operation and subsequent damage of the structure, a new assessment was required. It was found that some beams and one column were characterized by inadequate main and shear reinforcement as well as corrosion of many stirrups at beams. The strengthening solution adopted was based on carbon fibre reinforced polymer composites for beams and column.</p>

2016 ◽  
Vol 78 (5) ◽  
Author(s):  
Abdul Aziz Abdul Samad ◽  
Noorwirdawati Ali ◽  
Noridah Mohamad ◽  
J. Jayaprakash ◽  
Tuan Duc Ngo ◽  
...  

Strengthening of reinforced concrete (RC) continuous beams in shear have received very little attention among researchers even though most existing structures are in the form of continuous condition such as part of a floor-beam system. Therefore, in order to address the gap, a study on shear strengthening and shear repair of reinforced concrete continuous beam using Carbon Fibre Reinforced Polymer (CFRP) strips was conducted [15].  The validation of the experimental results was conducted with a simulation study using a finite element software ATENA v4 [16].  The research variables were number of layers of CFRP strips (one or two layers), wrapping schemes (four sides or three sides) and orientation of CFRP strips (0/90 or 45/135 degree’s). From the analysis of the finite element results, ATENA shows it has successfully simulated the shear behaviour of strengthened and repaired of 2-span continuous RC beams externally bonded by CFRP strips. 


2010 ◽  
Vol 56 (2) ◽  
pp. 111-122 ◽  
Author(s):  
W. Głodkowska ◽  
M. Ruchwa

Abstract This paper presents the possibility to apply numerical simulation in static analysis of reinforced concrete structure strengthened with carbon fibre reinforced polymer composite strips (CFRP). Reinforced concrete beams, with strengthening in form values CFRP made of carbon fibres and epoxy resin, featuring various width, as well as non-strengthened bent beams, were analysed. The simply supported beams arranged in a free support scheme were subjected to two concentrated forces within full range of loading (until collapse). The numerical analysis was performed through application of the Finite Elements Method (FEM), and the calculation model applied took into account the geometric and physical nonlinearity. The problem was solved by application of the quasi-static strategy method of calculations using ABAQUS software. While analysing the results, we focused on the run of changes in structure displacement and development of material damage, up to the point of destruction of the beam


2019 ◽  
Vol 22 (7) ◽  
pp. 1739-1754
Author(s):  
Ahmad Azim Shukri ◽  
Zainah Ibrahim ◽  
Huzaifa Hashim

The primary mode of premature failure for near-surface mounted strengthened beams is the concrete cover separation. Due to its complexity, most of the prediction methods for concrete cover separation tend to be empirical based, which can limit their usage to specific near-surface mounted strengthening configurations. In response to that, this article presents a mechanics-based design which uses the moment-rotation approach and the global energy balance approach which is less reliant on empirical formulations, as the mechanics of reinforced concrete beam such as tension stiffening and propagation of concrete cover separation debonding crack are directly simulated rather than empirically derived. The proposed design procedure was validated against published experimental results of reinforced concrete beams strengthened with near-surface mounted carbon fibre–reinforced polymer bars, near-surface mounted carbon fibre–reinforced polymer strips or side-near-surface mounted carbon fibre–reinforced polymer bars and show good accuracy. As it is less reliant on empirical formulations, the proposed design procedure should be applicable to various near-surface mounted reinforcement configurations and materials.


2021 ◽  
pp. 136943322110015
Author(s):  
Akram S. Mahmoud ◽  
Ziadoon M. Ali

When glass fibre-reinforced polymer (GFRP) bar splices are used in reinforced concrete sections, they affect the structural performance in two different ways: through the stress concentration in the section, and through the configuration of the GFRP–concrete bond. This study experimentally investigated a new method for increasing the bond strength of a GFRP lap (two GFRP bars connected together) using a carbon fibre-reinforced polymer (CFRP) sheet coated in epoxy resin. A new splicing method was investigated to quantify the effect of the bar surface bond on the development length, with reinforced concrete beams cast with laps in the concrete reinforcing bars at a known bending span length. Specimens were tested in four-point flexure tests to assess the strength capacity and failure mode. The results were summarised and compared within a standard lap made according to the ACI 318 specifications. The new method for splicing was more efficient for GFRP splice laps than the standard lap method. It could also be used for head-to-head reinforcement bar splices with the appropriate CFRP lapping sheets.


2017 ◽  
Vol 20 (11) ◽  
pp. 1658-1670 ◽  
Author(s):  
Shizhu Tian ◽  
Hongxing Jia ◽  
Yuanzheng Lin

The behaviour of bridge columns strengthened using carbon fibre–reinforced polymer composites has been studied extensively. However, few investigations have been conducted regarding the influence of carbon fibre–reinforced polymer-strengthened columns on the seismic behaviour of reinforced concrete continuous girder bridges. This article details the hybrid simulations of a continuous reinforced concrete girder bridge whose columns are strengthened by carbon fibre–reinforced polymer jackets. In the hybrid simulations, one ductile column is selected as the experimental element, which is represented by a 1/2.5-scale specimen, and the remaining bridge parts are simultaneously modelled in OpenSees (the Open System for Earthquake Engineering Simulation). After combining the experimental element and the numerical substructure, the hybrid analysis model is developed with the established hybrid simulation system. The displacements of the bridge and the lateral force–displacement response of the experimental element in hybrid simulation are obtained. Compared with the results of numerical simulation, the stability and accuracy of the established hybrid simulation system are demonstrated. Meanwhile, the comparative hybrid simulation results of the as-built bridge and the carbon fibre–reinforced polymer-strengthened bridge also prove the effectiveness of the carbon fibre–reinforced polymer jackets’ confinement in the continuous reinforced concrete girder bridge.


Author(s):  
Masami Fujita ◽  
Terumitsu Takahashi ◽  
Kazuhiro Kuzume ◽  
Tamon Ueda ◽  
Akira Kobayashi

<p>Reinforced concrete (RC) box girders of the Chofu Bridge had been strengthened using tensioned carbon fibre reinforced polymer (CFRP) strip method. Before and after the CFRP application, on-site load tests of the bridge were conducted using a 45 t weight vehicle.</p>