scholarly journals Reliability and Construct Validity of Self-Report Questionnaires for Patients With Pelvic Girdle Pain

2012 ◽  
Vol 92 (1) ◽  
pp. 111-123 ◽  
Author(s):  
Margreth Grotle ◽  
Andrew M. Garratt ◽  
Hanne Krogstad Jenssen ◽  
Britt Stuge

Background There is little evidence for the measurement properties of instruments commonly used for women with pelvic girdle pain. Objective The aim of this study was to examine the internal consistency, test-retest reliability, and construct validity of instruments used for women with pelvic girdle pain. Design This was a cross-sectional methodology study, including test-retest reliability assessment. Methods Women with pelvic girdle pain in pregnancy and after delivery participated in a postal survey that included the Pelvic Girdle Questionnaire (PGQ), Oswestry Disability Index (ODI), Disability Rating Index (DRI), Fear-Avoidance Beliefs Questionnaire (FABQ), Pain Catastrophizing Scale (PCS), and 8-item version of the Medical Outcomes Study 36-Item Short-Form Health Survey questionnaire (SF-36). Test-retest reliability was assessed with a random subsample 1 week later. Internal consistency was assessed with the Cronbach alpha, and test-retest reliability was assessed with the intraclass correlation coefficient (ICC) and minimal detectable change (MDC). Construct validity based on hypotheses was assessed by correlation analysis. Discriminant validity was assessed with the area under the receiver operating characteristic curve. Results All participants responded to the main (N=87) and test-retest (n=42) surveys. Cronbach alpha values ranged from .88 to .94, and ICCs ranged from .78 to .94. The MDC at the individual level constituted about 7% to 14% of total scores for the 8-item version of the SF-36, ODI, and PGQ activity subscale; about 18% to 22% for the DRI, PGQ symptom subscale, and PCS; and about 25% for the FABQ. Hypotheses were mostly confirmed by correlations between the instruments. The PGQ was the only instrument that significantly discriminated participants who were pregnant from participants who were not pregnant as well as pain locations. Limitations A comparison of responsiveness to change of the various instruments used in this study was not undertaken, but will be carried out in a future study. Conclusions Self-report instruments for assessing health showed good internal consistency, test-retest reliability, and construct validity for women with pelvic girdle pain. The PGQ was the only instrument with satisfactory discriminant validity, thus, it is recommended for evaluating symptoms and disability in patients with pelvic girdle pain.

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Tung-Hee Albert Tie ◽  
Chih-Kai Hong ◽  
Illich Chua ◽  
Fa-Chuan Kuan ◽  
Wei-Ren Su ◽  
...  

Abstract Background The patient self-report section of the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASESp) is one of the most validated and reliable assessment tools. This study aimed to establish a validated Chinese version of ASESp (ASESp-CH). Methods A clinical prospective study was performed (ClinicalTrials.gov Identifier: NCT04755049; registered on 2021/02/11). Following the guidelines of forward-backward translation and cross-cultural adaptation, a Chinese version of ASESp was established. Patients older than 18 years with shoulder disorders were included. Patients who could not complete test-retest questionnaires within the interval of 7–30 days and patients who received interventions were excluded. Intraclass correlation (ICC) was calculated for test- retest reliability, whereas internal consistency was determined by Cronbach value. Construct validity was evaluated by comparing the corresponding domains between the ASESp-CH and a validated Chinese version of 36-Item Short Form Health Survey (SF-36). Results A total of 86 patients were included with a mean test-retest interval of 12 ± 5.4 days. Test-retest reliability was excellent with an ICC of 0.94. Good internal consistency was found, with a Cronbach alpha of 0.86. Construct validity of the ASESp-CH questionnaire was good. The major domains of the ASESp-CH were significantly correlated with the respective domains in the SF-36 (p <  0.01), except for the domain of stability of ASESp-CH. Conclusions The Chinese version of ASESp questionnaire is a highly validated and reliable tool for shoulder disorder assessment.


2004 ◽  
Vol 94 (2) ◽  
pp. 482-484 ◽  
Author(s):  
Greg E. Dear

The Holyoake Codependency Index is a 13-item self-report measure of three aspects of codependency: External Focus, Self-sacrifice, and a sense of being overwhelmed by another person's problematic behavior (termed Reactivity). Previous studies have supported internal validity and the internal consistency and construct validity of the subscales. The present scores for 59 students indicate full scale test-retest reliability of .88 and for subscales (.76 to .82) over a 3-wk. interval.


2011 ◽  
Vol 108 (2) ◽  
pp. 673-674 ◽  
Author(s):  
Sevginar Vatan ◽  
Sedar Ertas ◽  
David Lester

In a sample of 100 Turkish psychiatric patients with diagnoses of anxiety disorders, Lester's Helplessness, Hopelessness, and Haplessness inventory had moderate estimates of internal consistency, test-retest reliability, and construct validity.


2010 ◽  
Vol 26 (1) ◽  
pp. 11-18 ◽  
Author(s):  
Sara Germans ◽  
Guus L. Van Heck ◽  
Douglas R. Langbehn ◽  
Paul P.G. Hodiamont

The internal consistency, test-retest reliability, and predictive validity of the Iowa Personality Disorder Screen (IPDS) as a screening instrument for personality disorders (PDs) were studied in 195 Dutch psychiatric outpatients, using the SCID-II as the gold standard. All patients completed a self-administered version of the IPDS. Internal consistency was moderate (0.64), and the test-retest reliability was good (0.87). According to the SCID-II, 97 patients (50%) had at least one personality disorder (PD). The IPDS correctly classified 81.0 percent of all participants in the category PD present/absent. The sensitivity and specificity were 77% and 88%, respectively. Positive and negative predictive values were 83% and 79%. Test-retest reliability after a 2-week interval was 0.87. These results are comparable with those reported in earlier studies with respect to the interview version of the IPDS and more promising than previously reported results obtained with a self-report version of the IPDS. Therefore, it is concluded that a self-report version of the IPDS may be useful as a screening measure for determining the presence/absence of PD in a population of psychiatric outpatients.


2018 ◽  
Vol 41 (5) ◽  
pp. 425-433
Author(s):  
Luan Simões ◽  
Luci Fuscaldi Teixeira-Salmela ◽  
Lívia Magalhães ◽  
Britt Stuge ◽  
Glória Laurentino ◽  
...  

2017 ◽  
Vol 4 ◽  
Author(s):  
E. E. Haroz ◽  
J. Bass ◽  
C. Lee ◽  
S. S. Oo ◽  
K. Lin ◽  
...  

BackgroundSelf-report measurement instruments are commonly used to screen for mental health disorders in Low and Middle-Income Countries (LMIC). The Western origins of most depression instruments may constitute a bias when used globally. Western measures based on the DSM, do not fully capture the expression of depression globally. We developed a self-report scale design to address this limitation, the International Depression Symptom Scale-General version (IDSS-G), based on empirical evidence of the signs and symptoms of depression reported across cultures. This paper describes the rationale and process of its development and the results of an initial test among a non-Western population.MethodsWe evaluated internal consistency reliability, test–retest reliability and inter-rater reliability of the IDSS-G in a sample N = 147 male and female attendees of primary health clinics in Yangon, Myanmar. For criterion validity, IDSS-G scores were compared with diagnosis by local psychiatrists using the Structured Clinical Interview for DSM (SCID). Construct validity was evaluated by investigating associations between the IDSS-G and the Patient Health Questionnaire (PHQ), impaired function, and suicidal ideation.ResultsThe IDSS-G showed high internal consistency reliability (α = 0.92), test–retest reliability (r = 0.87), and inter-rater reliability (ICC = 0.90). Strong correlations between the IDSS-G and PHQ-9, functioning, and suicidal ideation supported construct validity. Criterion validity was supported for use of the IDSS-G to identify people with a SCID diagnosed depressive disorder (major depression/dysthymia). The IDSS-G also demonstrated incremental validity by predicting functional impairment beyond that predicted by the PHQ-9. Results suggest that the IDSS-G accurately assesses depression in this population. Future testing in other populations will follow.


Assessment ◽  
1994 ◽  
Vol 1 (4) ◽  
pp. 335-344 ◽  
Author(s):  
Gary R. Birchler ◽  
William Fals-Stewart

This study details the psychometric evaluation of the Response to Conflict Scale (RTC), a 24-item measure of maladaptive responses to marital conflict. The inventory showed high internal consistency, test-retest reliability, construct and discriminant validity, and classification efficiency. Clinical utility of the RTC is also discussed.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Kamelia Harris ◽  
Gillian Haddock ◽  
Sarah Peters ◽  
Patricia Gooding

Abstract Background Suicidal ideation is a key precursor for suicide attempts and suicide deaths. Performing routine screening of suicide precursors can help identify people who are at high risk of death by suicide. This is, arguably, an important suicide prevention effort. The aim of this study was to assess the validity, reliability, and factor structure of the Suicidal Ideation Attributes Scale (SIDAS) in a three-month longitudinal study with people with a diagnosis of schizophrenia or non-affective psychosis and experiences of suicidal ideation and/or behaviours. It was predicted that the SIDAS would have high internal consistency, test-retest reliability, convergent, discriminant and construct validity. Methods Ninety-nine participants experiencing psychosis completed the SIDAS at baseline and 89 participants completed it 3 months later. Additionally, participants completed a demographic questionnaire, the Beck Scale for Suicide Ideation, the Beck Hopelessness Scale, and the Defeat and Entrapment Scales. The internal consistency, test-retest reliability, convergent validity, and discriminant validity of the SIDAS were investigated in comparison to other constructs. Factor analysis was performed to examine the factor structure of the scale. Results Principal component analysis yielded a theoretically coherent one-dimensional factor structure of SIDAS, suggesting good construct validity (PCA = .71). The SIDAS had high internal consistency (α = .89) and good test-retest reliability (α = .73). It was highly correlated with other self-report measures, including the Beck Scale for Suicide Ideation, Beck Hopelessness Scale, Defeat and Entrapment scales, indicating excellent construct validity. Conclusion The SIDAS is a valid and reliable self-report instrument for assessing the severity of suicidal ideation in a population of people with a diagnosis of schizophrenia or non-affective psychosis. Further research should test the psychometric properties of the scale in individuals experiencing different mental health problems in cross-cultural settings, in order to establish its broader validity, reliability, and clinical utility.