Effect of Transducer Velocity on Intramuscular Temperature During a 1-MHz Ultrasound Treatment

2006 ◽  
Vol 36 (5) ◽  
pp. 320-325 ◽  
Author(s):  
Stephanie L. Weaver ◽  
Timothy J. Demchak ◽  
Marcus B. Stone ◽  
Jody B. Brucker ◽  
Phillip O. Burr
2013 ◽  
Vol 22 (4) ◽  
pp. 296-300
Author(s):  
Daniel Krasinski ◽  
Ashley B. Thrasher ◽  
Michael G. Miller ◽  
William R. Holcomb

Context:A potential variable that could affect rate of temperature elevation with ultrasound is the pressure (mass) that is applied to the transducer head during application. Added pressure could compress the tissue, affecting density and the transmission of ultrasound energy. Little research has been completed to determine the effects of the amount of pressure applied during therapeutic ultrasound in vivo.Objective:To determine the effects of different applied transducer mass on intramuscular temperature during an ultrasound treatment within the left triceps surae.Design:Crossover clinical trial.Setting:Human performance research laboratory.Participants:Convenience sample of thirteen healthy, college-age students.Interventions:Three separate MHz, 1.0-W/cm2 ultrasound treatments were administered 1.5 cm within the triceps surae. The independent variables were the linear temperature standards (0.5°C, 1.0°C, 1.5°C, and 2.0°C above baseline) and the 3 different applied pressures measured in grams (200 g, 600 g, and 800 g).Main Outcome Measures:A thermocouple probe was used to measure triceps surae temperature, and time to reach the temperature standards was recorded during the ultrasound treatments. A 4 × 3 repeated-measures analysis of variance (RM-ANOVA) was used to analyze the differences for temperature points (0.5°C, 1.0°C, 1.5°C, and 2.0°C) and transducer mass (200 g, 600 g, and 800 g) and with respect to time.Results:The results of the RM-ANOVA showed no temperature-point and transducer-mass interaction (F6,72 = 1.69, P = .137) or main effect for mass (F2,24 = 1.23, P = .309). The time required to raise temperature 2°C was 209.1 ± 68.10 s at 200 g, 181.5 ± 61.50 s at 600 g, and 194.9 ± 75.54 s at 800 g.Conclusions:Under the conditions of this study, the amount of mass applied with the transducer during an ultrasound treatment does not ultimately affect the rate of tissue heating.


2019 ◽  
Vol 56 (3) ◽  
pp. 652-656
Author(s):  
Raul Chioibas ◽  
Florin Borcan ◽  
Ovidiu Mederle ◽  
Dana Stoian ◽  
Codruta Marinela Soica

Zinc oxide (ZnO) is an inorganic compound used for its antiseptic and skin healing properties. It is an excellent protective filter against UV radiation and it can be used as white pigment in pharmaceutical preparations. In this study, nano-ZnO particles were obtained by ultrasound treatment, and respectively by repeated freezing/heating process. The influence of synthesis method and of ultrasound generator parameters on the particles size and stability was observed. The results reveal that were obtained samples with a very good stability and sizes between 15 and 96 nm. It was found that synthesis based on ultrasound treatment lead to the formation of nanoparticles with lower sizes.


2021 ◽  
pp. 129669
Author(s):  
Leticia Martínez Lapuente ◽  
Zenaida Guadalupe ◽  
Belén Ayestarán ◽  
Paula Pérez-Porras ◽  
Ana Belén Bautista-Ortín ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jeong Yu Lee ◽  
Dae-Jin Min ◽  
Wanil Kim ◽  
Bum-Ho Bin ◽  
Kyuhan Kim ◽  
...  

AbstractInspired by the effectiveness of low-intensity ultrasound on tissue regeneration, we investigated the potential effect of short-term high-intensity ultrasound treatment for acceleration of wound healing in an in vitro wound model and dermal equivalent, both comprising human dermal fibroblasts. Short-term ultrasound of various amplitudes significantly increased the proliferation and migration of fibroblasts and subsequently increased the production of the extracellular matrix components fibronectin and collagen type I, both of which are important for wound healing and are secreted by fibroblasts. In addition, ultrasound treatment increased the contraction of a fibroblast-embedded three-dimensional collagen matrix, and the effect was synergistically increased in the presence of TGF-β. RNA-sequencing and bioinformatics analyses revealed changes in gene expression and p38 and ERK1/2 MAPK pathway activation in the ultrasound-stimulated fibroblasts. Our findings suggest that ultrasound as a mechanical stimulus can activate human dermal fibroblasts. Therefore, the activation of fibroblasts using ultrasound may improve the healing of various types of wounds and increase skin regeneration.


Sign in / Sign up

Export Citation Format

Share Document