Computational Study of Wing Tip Effect for the Flow Control Authority of DBD Plasma Actuator

2019 ◽  
Author(s):  
Takumi Abe ◽  
Kengo Asada ◽  
Satoshi Sekimoto ◽  
Koji Fukudome ◽  
Hiroya Mamori ◽  
...  
Aerospace ◽  
2021 ◽  
Vol 8 (12) ◽  
pp. 396
Author(s):  
Takuto Ogawa ◽  
Kengo Asada ◽  
Satoshi Sekimoto ◽  
Tomoaki Tatsukawa ◽  
Kozo Fujii

A computational study was conducted on flows over an NACA0015 airfoil with dielectric barrier discharge (DBD) plasma. The separated flows were controlled by a DBD plasma actuator installed at the 5% chord position from the leading edge, where operated AC voltage was modulated with the duty cycle not given a priori but dynamically changed based on the flow fluctuations over the airfoil surface. A single-point pressure sensor was installed at the 40% chord position of the airfoil surface and the DBD plasma actuator was activated and deactivated based on the strength of the measured pressure fluctuations. The Reynolds number was set to 63,000 and flows at angles of attack of 12 and 16 degrees were considered. The three-dimensional compressible Navier–Stokes equations including the DBD plasma actuator body force were solved using an implicit large-eddy simulation. Good flow control was observed, and the burst frequency proven to be effective in previous fixed burst frequency studies is automatically realized by this approach. The burst frequency is related to the characteristic pressure fluctuation; our approach was improved based on the findings. This improved approach realizes the effective burst frequency with a lower control cost and is robust to changing the angle of attack.


2017 ◽  
Vol 31 (32) ◽  
pp. 1850038 ◽  
Author(s):  
Xin Zhang ◽  
Huaxing Li ◽  
Kwing So Choi ◽  
Longfei Song

The structures of a flow field induced by a plasma actuator were investigated experimentally in quiescent air using high-speed Particle Image Velocimetry (PIV) technology. The motivation behind was to figure out the flow control mechanism of the plasma technique. A symmetrical Dielectric Barrier Discharge (DBD) plasma actuator was mounted on the suction side of the SC (2)-0714 supercritical airfoil. The results demonstrated that the plasma jet had some coherent structures in the separated shear layer and these structures were linked to a dominant frequency of [Formula: see text] = 39 Hz when the peak-to-peak voltage of plasma actuator was 9.8 kV. The high speed PIV measurement of the induced airflow suggested that the plasma actuator could excite the flow instabilities which lead to production of the roll-up vortex. Analysis of transient results indicated that the roll-up vortices had the process of formation, movement, merging and breakdown. This could promote the entrainment effect of plasma actuator between the outside airflow and boundary layer flow, which is very important for flow control applications.


2015 ◽  
Vol 137 (11) ◽  
Author(s):  
Theodoros Michelis ◽  
Marios Kotsonis

A wind tunnel study is conducted toward hybrid flow control of a full scale transport truck side mirror at ReD=3.2×105. A slim guide vane is employed for redirecting high-momentum flow toward the mirror wake region. Leading edge separation from the guide vane is reduced or eliminated by means of an alternating current -dielectric barrier discharge (AC-DBD) plasma actuator. Particle image velocimetry (PIV) measurements are performed at a range of velocities from 15 to 25 m/s and from windward to leeward angles from -5deg to 5deg. Time-averaged velocity fields are obtained at the center of the mirror for three scenarios: (a) reference case lacking any control elements, (b) guide vane only, and (c) combination of the guide vane and the AC-DBD plasma actuator. The comparison of cases demonstrates that at 25 m/s windward conditions (-5deg) the guide vane is capable of recovering 17% momentum with respect to the reference case. No significant change is observed by activating the AC-DBD plasma actuator. In contrast, at leeward conditions (5deg), the guide vane results in a −20% momentum loss that is rectified to a 6% recovery with actuation. The above implies that for a truck with two mirrors, 23% of momentum may be recovered.


Author(s):  
Jianyang Yu ◽  
Wenchun Bao ◽  
Fu Chen ◽  
Yanping Song ◽  
Cong Wang

Abstract The dielectric barrier discharge (DBD) plasma actuator, in which electrodes are asymmetric arranged, has already demonstrated its ability in flow control. In the present work, the configuration of multiple plasma actuators is placed at the suction side of the cascade top to realize the tip leakage control. However, massive configurations appear when the number of plasma actuators increases, resulting in the investigation of actuator configuration for tip leakage flow control becomes a challenge. The surrogate modelling approach provides a cheap and efficient method to investigate the effect of multiple plasma actuators on the tip leakage flow control. By constructing an approximation model, tip leakage mass flow rates of all configuration are obtained in the present work. What’s more, the flow structures in the tip clearance controlled by the plasma actuators are explained in the process of topological analysis. The results show that the tip leakage mass flow rate is decreasing with the number of active plasma actuators increasing. However, the decreasing would reach its limits in the process of adding plasma actuators. In the analysis of flow topology, single actuator would generate a small vortex at the suction side to cause an obstacle in the tip leakage flow. While the continuous arrangements of plasma actuator is beneficial to generate an induced vortex to diminish the tip leakage flow.


Sign in / Sign up

Export Citation Format

Share Document