Numerical Simulation of Transient Air Flow in a Large Scale High Density Data Centers

Author(s):  
Essam E. Khalil ◽  
Yousri E. AbdelRahman ◽  
Waleed Abdelmaksoud ◽  
Esmail E. ElBialy
Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6147
Author(s):  
Jinkyun Cho ◽  
Jesang Woo ◽  
Beungyong Park ◽  
Taesub Lim

Removing heat from high-density information technology (IT) equipment is essential for data centers. Maintaining the proper operating environment for IT equipment can be expensive. Rising energy cost and energy consumption has prompted data centers to consider hot aisle and cold aisle containment strategies, which can improve the energy efficiency and maintain the recommended level of inlet air temperature to IT equipment. It can also resolve hot spots in traditional uncontained data centers to some degree. This study analyzes the IT environment of the hot aisle containment (HAC) system, which has been considered an essential solution for high-density data centers. The thermal performance was analyzed for an IT server room with HAC in a reference data center. Computational fluid dynamics analysis was conducted to compare the operating performances of the cooling air distribution systems applied to the raised and hard floors and to examine the difference in the IT environment between the server rooms. Regarding operating conditions, the thermal performances in a state wherein the cooling system operated normally and another wherein one unit had failed were compared. The thermal performance of each alternative was evaluated by comparing the temperature distribution, airflow distribution, inlet air temperatures of the server racks, and recirculation ratio from the outlet to the inlet. In conclusion, the HAC system with a raised floor has higher cooling efficiency than that with a hard floor. The HAC with a raised floor over a hard floor can improve the air distribution efficiency by 28%. This corresponds to 40% reduction in the recirculation ratio for more than 20% of the normal cooling conditions. The main contribution of this paper is that it realistically implements the effectiveness of the existing theoretical comparison of the HAC system by developing an accurate numerical model of a data center with a high-density fifth-generation (5G) environment and applying the operating conditions.


2007 ◽  
Vol 31 (2) ◽  
pp. 352-356 ◽  
Author(s):  
J. Todd Auman ◽  
Gary A. Boorman ◽  
Ralph E. Wilson ◽  
Gregory S. Travlos ◽  
Richard S. Paules

Clinical chemistry data are routinely generated as part of preclinical animal toxicity studies and human clinical studies. With large-scale studies involving hundreds or even thousands of samples in multiple treatment groups, it is currently difficult to interpret the resulting complex, high-density clinical chemistry data. Accordingly, we conducted this study to investigate methods for easy visualization of complex, high-density data. Clinical chemistry data were obtained from male rats each treated with one of eight different acute hepatotoxicants from a large-scale toxicogenomics study. The raw data underwent a Z-score transformation comparing each individual animal's clinical chemistry values to that of reference controls from all eight studies and then were visualized in a single graphic using a heat map. The utility of using a heat map to visualize high-density clinical chemistry data was explored by clustering changes in clinical chemistry values for >400 animals. A clear distinction was observed in animals displaying hepatotoxicity from those that did not. Additionally, while animals experiencing hepatotoxicity showed many similarities in the observed clinical chemistry alterations, distinct differences were noted in the heat map profile for the different compounds. Using a heat map to visualize complex, high-density clinical chemistry data in a single graphic facilitates the identification of previously unrecognized trends. This method is simple to implement and maintains the biological integrity of the data. The value of this clinical chemistry data transformation and visualization will manifest itself through integration with other high-density data, such as genomics data, to study physiology at the systems level.


The quality of dried product can be enhanced in cabinet tray dryers through a uniform distribution of drying air flow and temperature. In this work, a numerical investigation is conducted to examine the consequence of air movement on the quality of product dried in a convective tray dryer. The temperature and velocity contours of air in the drying chamber are numerically determined for three different geometries of cabinet tray dryer and are compared. A good harmony is found between the predicted data from CFD and experimental data from the literature. This work will enable us to optimize the drying chamber design for uniform dispersal of air flow and temperature and to improve quality of dried product for large scale applications


Sign in / Sign up

Export Citation Format

Share Document