A Plasma Flow Control Concept for Propeller Boundary Layer Separation Suppression

Author(s):  
Tyler Zimbelman ◽  
Kurt P. Rouser
Author(s):  
J. Saavedra ◽  
G. Paniagua

The aerothermal performance of the low pressure turbine in UAVs’ is significantly abated at high altitude, due to boundary layer separation. During past years different flow control strategies have been proposed to prevent boundary layer separation, such as dielectric barrier discharges, synthetic jets, vortex generators. However, the optimization of the control approach requires a better characterization of the separated regions at several frequencies. The present investigation analyzes the behavior of separated flows, and specifically reports the inception, reattachment and separation length, that allows the development of more efficient methods to manipulate flow separation under non-tempo-rally uniform inlet conditions. The development of separated flows under sudden flow accelerations or pulsating inlet conditions were investigated with series of numerical simulations including Unsteady Reynolds Average Navier Stokes and Large Eddy Simulations. The present research was performed on a wall mounted hump, which imposes an adverse pressure gradient representative of the suction side of low pressure turbines. The heat transfer and wall shear stresses were fully documented, as well as the flow velocity and temperature profiles at different axial locations to characterize the near wall flow properties and the thermal boundary layer. Through a sudden flow acceleration we looked into the dynamic response of the shear layer detachment as it is modulated by the mean flow evolution. Similarly, we studied the behavior of the recirculation bubble under periodic disturbances imposed by sinusoidal inlet total pressure signals at various frequencies ranging from 10 to 500 Hz. During each period the Reynolds number oscillates between 40000 and 180000 (based on a characteristic length of 0.1 m). Finally, as a first step into the flow control approach we added a slot in our geometry to allow flow injection and ingestion just upstream of the separation inception. Exploring the behavior of the separated region at different slot pressure conditions we defined the envelope for its periodic actuation. Thanks to that analysis, we found that matching the actuator frequency with the frequency response of the separated region the performance of the actuation is boosted.


2019 ◽  
Vol 9 (24) ◽  
pp. 5495 ◽  
Author(s):  
Xin-kai Li ◽  
Wei Liu ◽  
Ting-jun Zhang ◽  
Pei-ming Wang ◽  
Xiao-dong Wang

During the operation of wind turbines, flow separation appears at the blade roots, which reduces the aerodynamic efficiency of the wind turbine. In order to effectively apply vortex generators (VGs) to blade flow control, the effect of the VG spacing (λ) on flow control is studied via numerical calculations and wind tunnel experiments. First, the large eddy simulation (LES) method was used to calculate the flow separation in the boundary layer of a flat plate under an adverse pressure gradient. The large-scale coherent structure of the boundary layer separation and its evolution process in the turbulent flow field were analyzed, and the effect of different VG spacings on suppressing the boundary layer separation were compared based on the distance between vortex cores, the fluid kinetic energy in the boundary layer, and the pressure loss coefficient. Then, the DU93-W-210 airfoil was taken as the research object, and wind tunnel experiments were performed to study the effect of the VG spacing on the lift–drag characteristics of the airfoil. It was found that when the VG spacing was λ/H = 5 (H represents the VG’s height), the distance between vortex cores and the vortex core radius were approximately equal, which was more beneficial for flow control. The fluid kinetic energy in the boundary layer was basically inversely proportional to the VG spacing. However, if the spacing was too small, the vortex was further away from the wall, which was not conducive to flow control. The wind tunnel experimental results demonstrated that the stall angle-of-attack (AoA) of the airfoil with the VGs increased by 10° compared to that of the airfoil without VGs. When the VG spacing was λ/H = 5, the maximum lift coefficient of the airfoil with VGs increased by 48.77% compared to that of the airfoil without VGs, the drag coefficient decreased by 83.28%, and the lift-to-drag ratio increased by 821.86%.


2012 ◽  
Vol 25 ◽  
pp. 01078
Author(s):  
Lukas Popelka ◽  
Jana Kuklova ◽  
David Simurda ◽  
Natalie Souckova ◽  
Milan Matejka ◽  
...  

Author(s):  
Y. Guendogdu ◽  
A. Vorreiter ◽  
J. R. Seume

Aerofoil active flow control has been attempted to increase the permissible loading of boundary layers in gas turbine components. Steady suction and blowing, pulsing and synthetic jets are all means to remove low energy flow, replace momentum deficits, or promote mixing to inhibit boundary layer separation. A curved surface near the trailing edge (“Coanda surface”) is another technique used to control aerofoil boundary layer separation. This paper presents the design of a stator with active flow control for a high speed compressor using a Coanda surface. The Coanda surface is located behind an injection slot on the aerofoil suction side of the first stage of a four-stage high speed research compressor. The design method and the present results are based on steady numerical calculations. The design intent is to reduce the number of vanes. This active flow control is used to maintain the flow exit angle of the reference stator despite the resulting increase in stator loading. It is shown that the solidity of the flow-controlled stator can be decreased by 25% with a blowing rate of 0.5% of the main mass flow.


2013 ◽  
Vol 135 (4) ◽  
Author(s):  
Kin Pong Lo ◽  
Christopher J. Elkins ◽  
John K. Eaton

Conical diffusers are often installed downstream of a turbomachine with a central hub. Previous studies showed that nonstreamlined hubs had extended separated wakes that reduced the adverse pressure gradient in the diffuser. Active flow control techniques can rapidly close the central separation bubble, but this restores the adverse pressure gradient, which can cause the outer wall boundary layer to separate. The present study focuses on the use of a step-wall diffuser to stabilize the wall boundary layer separation in the presence of core flow control. Three-component mean velocity data for a set of conical diffusers were acquired using magnetic resonance velocimetry. The results showed the step-wall diffuser stabilized the wall boundary layer separation by fixing its location. An axisymmetric step separation bubble was formed. A step with a periodically varying height reduced the reattachment length of the step separation and allowed the diffuser to be shortened. The step-wall diffuser was found to be robust in a range of core flow velocity profiles. The minimum distance between the core flow control mechanism and the step-wall diffuser as well as the minimum length of the step were determined.


Author(s):  
J. Saavedra ◽  
G. Paniagua

The aerothermal performance of the low-pressure turbine in unmanned aerial vehicles is significantly abated at high altitude, due to boundary layer separation. Different flow control strategies have been proposed to prevent boundary layer separation, such as dielectric barrier discharges (DBD) and synthetic jets. However, the optimization of the control approach requires a better characterization of the separated regions at transient conditions. The present investigation analyzes the behavior of separated flows, reporting the inception and separation length, allowing the development of efficient flow control methods under nontemporally uniform inlet conditions. The development of separated flows was investigated with numerical simulations including Unsteady Reynolds average Navier–Stokes (URANS) and large Eddy simulations (LES). The present research was performed on a wall-mounted hump, which imposes a pressure gradient representative of the suction side of low pressure turbines. Through sudden flow accelerations, we looked into the dynamic response of the shear layer detachment as it is modulated by the mean flow evolution. Similarly, we studied the behavior of the recirculation bubble under periodic disturbances imposed at various frequencies ranging from 10 to 500 Hz, at which the Reynolds number oscillates between 40,000 and 180,000. As a first step into the flow control, we added a slot to allow flow injection and ingestion upstream of the separation inception. Exploring the behavior of the separated region at different conditions, we defined the envelope for its periodic actuation. We found that by matching the actuator frequency with the frequency response of the separated region, the performance of the actuation is boosted.


Author(s):  
Aria Alimi ◽  
Olaf Wünsch

Active flow control of canonical laminar separation bubbles by steady and harmonic vortex generator jets (VGJs) was investigated using direct numerical simulations. Both control strategies were found to be effective in controlling the laminar boundary-layer separation. However, the present results indicate that using the same blowing amplitude, harmonic VGJs were more effective and efficient in reducing the separated region than the steady VGJs considering the fact that the harmonic VGJs use less momentum than the steady case. For steady VGJs, longitudinal structures formed immediately downstream of injection location led to formation of hairpin-type vortices causing an earlier transition to turbulence. Symmetric hairpin vortices were shown to develop downstream of the forcing location for the harmonic VGJs as well. However, the increased control effectiveness for harmonic VGJs flow control strategy is attributed to the fact that shear-layer instability mechanism was exploited. As a result, disturbances introduced by VGJs were strongly amplified leading to development of large-scale coherent structures, which are very effective in increasing the momentum exchange, thus, limiting the separated region.


Author(s):  
Aria Alimi ◽  
Olaf Wünsch

Active flow control of canonical laminar separation bubbles by steady and harmonic vortex generator jets (VGJs) was investigated using direct numerical simulations. Both control strategies were found to be effective in controlling the laminar boundary-layer separation. However, the present results indicate that using the same blowing amplitude, harmonic VGJs were more effective and efficient in reducing the separated region than the steady VGJs considering the fact that the harmonic VGJs use less momentum than the steady case. For steady VGJs, longitudinal structures formed immediately downstream of injection location led to formation of hairpin-type vortices causing an earlier transition to turbulence. Symmetric hairpin vortices were shown to develop downstream of the forcing location for the harmonic VGJs as well. However, the increased control effectiveness for harmonic VGJs flow control strategy is attributed to the fact that shear-layer instability mechanism was exploited. As a result, disturbances introduced by VGJs were strongly amplified leading to development of large-scale coherent structures, which are very effective in increasing the momentum exchange, thus, limiting the separated region.


Sign in / Sign up

Export Citation Format

Share Document