scholarly journals Water quality in a pipe distribution network: a case study of a communal water distribution network in Ibadan, Nigeria

Author(s):  
M. S. Awopetu ◽  
A. O. Coker ◽  
J. O. Aribisala ◽  
S. O. Awopetu
2019 ◽  
Vol 166 ◽  
pp. 180-185
Author(s):  
Danial Nayeri ◽  
Seyyed Alireza Mousavi ◽  
Parastoo Darvishi ◽  
Arezoo Mahmoudi ◽  
Elham Noori ◽  
...  

2019 ◽  
Vol 2 (1) ◽  
pp. 11 ◽  
Author(s):  
Arif Susanto ◽  
Purwanto Purwanto ◽  
Agus Hadiyarto

Abstract:. The requirement of consumed drinking water so that it does not create disturbance to public health is that it needs a quality monitoring. Water fluoridation in Tembagapura City aims to reach its concentration level toward certain safe level, and it can provide maximum benefits for dental health. Analysis and simulation methods using EPAnet software. The results of hydrolic simulation and water quality for fluoride concentration of each node and link in the drinking water distribution network system have changed in every time change following the drinking water distribution segment. From hydraulic simulations, especially for head and flow at separate points, it consists of simultaneous solution in flow equivalence for every junction and headloss relationship in every link of network as a result of hydraulic balancing. New segment will be made at the end of each link that receives inflow from a node if the quality of the new node is different from the link in the last segment. Every pipe in network contains singular segment where the water quality is in line with the preliminary quality stated in the preliminary node. With the availability of hydraulic model and water quality for fluoride concentration, a further research can be conducted for chlorine decay, growth of by product i.e. Trihalomethans (THMs) as well as water age simultaneously in drinking water supply systems in Tembagapura City.  Keyword: EPAnet, distribution network, fluoride concentration. Abstrak: Persyaratan kualitas air minum yang dikonsumsi masyarakat agar tidak menimbulkan gangguan kesehatan, maka penyelenggara air minum perlu melakukan pemantauan kualitasnya. Fluoridasi air di Kota Tembagapura ditujukan untuk mencapai tingkat konsentrasi fluoride pada level tertentu yang aman dan dapat memberikan manfaat maksimal bagi kesehatan gigi. Metode analisis dan simulasi menggunakan perangkat lunak EPAnet. Hasil simulasi hidrolis dan kualitas air untuk konsentrasi fluoride pada setiap node dan link pada sistem jaringan distribusi air minum berubah pada setiap perubahan waktu mengikuti segmen distribusi air minum tersebut. Dari simulasi hidrolis, khusus untuk head dan aliran pada titik yang terpisah meliputi penyelesaian secara simultan dalam persamaan aliran untuk tiap sambungan (junction), dan hubungan headloss pada setiap link pada jaringan sebagai akibat dari hydrolic balancing. Segmen baru terbentuk pada akhir dari setiap link yang menerima inflow dari sebuah node, jika kualitas node baru berbeda dari link pada segmen terakhir. Setiap pipa dalam jaringan mengandung segmen tunggal, di mana kualitas air sebanding dengan kualitas awal yang ditetapkan di node awal. Dengan tersedianya model hidrolis dan kualitas air untuk konsentrasi fluoride, maka dapat dilakukan penelitian lanjutan untuk peluruhan klorin, pertumbuhan by product yaitu trihalomethans (THMs) serta usia air secara simultan pada sistem penyediaan air minum di Kota Tembagapura.Kata Kunci: EPAnet, jaringan distribusi, konsentrasi fluoride.


Author(s):  
Ahmed Al Naamani ◽  
Ahmad Sana

Abstract A water distribution network in an urban area in Muscat region (capital city of Oman) is assessed for operational performance using the widely accepted methodology proposed by International Water Association (IWA). The technical performance of this network was assessed using global performance index methods after modifying the performance levels as per local guidelines. A total of 37 operational performance indicators for the network were selected to carryout assessment. Overall operational performance showed high scores whereas some indicators showed unacceptable performance values. The network showed very high technical performance considering nodal pressures. The lower performance for pipe velocity may be attributed to the fact that the network is currently being utilized by 70% of the population for which it was designed. The residual chlorine levels were within the acceptable range of the Public Authority for Water (PAW) showing a very good performance by virtue of water quality. This study will be useful for the decision makers to assess the operational, technical and water quality performance of urban networks and take actions for improvements.


Proceedings ◽  
2018 ◽  
Vol 2 (11) ◽  
pp. 593
Author(s):  
Sorin Perju ◽  
Alexandru Aldea

This paper presents the results recorded by upgrading and rehabilitating the pumping stations for an urban water network with a primary goal of diminishing the operation and maintenance costs and a secondary goal of reducing the water losses in the water distribution network. The adopted technical solutions within the structural and functional modifications of the pumping stations have led to both the improvement of hydraulic parameters of the pumping stations and also the improvement of registered energy consumption. The undertaken modifications and transformations within the pumping stations led to significant energy savings and at the same time to important water losses reductions within the distribution network.


2020 ◽  
Vol 2 (1) ◽  
pp. 18 ◽  
Author(s):  
Marco Amos Bonora ◽  
Fabio Caldarola ◽  
Mario Maiolo ◽  
Joao Muranho ◽  
Joaquim Sousa

A new set of local performance indices has recently been introduced within a mathematical framework specifically designed to promote a local–global analysis of water networks. Successively, some local indices were also set up and implemented on WaterNetGen to better exploit their potential. In this paper, after a very brief overview of tools and main notations, Santarém’s (Portugal) water distribution network (WDN) is examined, applying to it the mentioned set of local indices, as a new real case study. The paper also focuses on the Hypotesis required to assess these indices in a pressure driven analysis (PDA) approach, analyzing and discussing the results obtained from such a simulation.


2006 ◽  
Vol 6 (4) ◽  
pp. 45-56
Author(s):  
J.W. Norton ◽  
W.J. Weber

Factors impacting the cost equivalency point for deploying strategically-located treatment units within a distributed optimal technology network (DOT-Net) to manage network-derived water quality degradation are defined and quantified. The cost equivalency point is essentially the ‘breakeven’ allowable cost for implementing DOT-Net strategy as an alternative to upgrading a central treatment facility to ‘pretreat’ water sufficiently to manage quality degradation within a potable water distribution network. For the purposes of the analysis presented, water quality is assumed to degrade linearly with time as it flows through the distribution network. Disinfection by-product (DBP) formation, selected as a representative water quality degradation parameter, was modeled to predict service population DBP exposure and resulting cost of centralized treatment plant upgrades to meet water quality goals. The equivalency point was determined by apportioning the anticipated cost for upgrading the centralized treatment facilities over the fraction of service connections receiving deficient quality water. Both concentration of DBP precursor material and service population size are found to have limited impact on the equivalency point of a distributed treatment unit. The advantages and disadvantages of various treatment methods available for in-network water treatment are outlined and the ancillary functional requirements of the distributed treatment unit are delineated.


Sign in / Sign up

Export Citation Format

Share Document