scholarly journals REDESIGN OF AN AXIAL COMPRESSOR WITH MASS FLOW REDUCTION OF 30%

Author(s):  
VIACHESLAV ALEKSEEVICH SEDUNIN ◽  
YURII MIRONOVICH BRODOV ◽  
OLEG VIACHESLAVOVICH KOMAROV ◽  
VITALIY LEONIDOVICH BLINOV ◽  
ALEXANDER VLADIMIROVICH SKOROKHODOV ◽  
...  
2016 ◽  
Vol 138 (12) ◽  
Author(s):  
Y. Bousquet ◽  
N. Binder ◽  
G. Dufour ◽  
X. Carbonneau ◽  
M. Roumeas ◽  
...  

The present paper numerically investigates the stall inception mechanisms in a centrifugal compressor stage composed of a splittered unshrouded impeller and a vaned diffuser. Unsteady numerical simulations have been conducted on a calculation domain comprising all the blade passages over 360 deg for the impeller and the diffuser. Three stable operating points are simulated along a speed line, and the full path to instability is investigated. The paper focusses first on the effects of the mass flow reduction on the flow topology at the inlet of both components. Then, a detailed analysis of stall inception mechanisms is proposed. It is shown that at the inlet of both components, the mass flow reduction induces boundary layer separation on the blade suction side, which results in a vortex tube having its upper end at the casing and its lower end at the blade wall. Some similarities with flows in axial compressor operating at stall condition are outlined. The stall inception process starts with the growth of the amplitude of a modal wave rotating in the vaneless space. As the flow in the compressor is subsonic, the wave propagates upstream and interacts with the impeller flow structure. This interaction leads to the drop in the impeller pressure ratio.


Author(s):  
Jinlan Gou ◽  
Wei Wang ◽  
Can Ma ◽  
Yong Li ◽  
Yuansheng Lin ◽  
...  

Using supercritical carbon dioxide (SCO2) as the working fluid of a closed Brayton cycle gas turbine is widely recognized nowadays, because of its compact layout and high efficiency for modest turbine inlet temperature. It is an attractive option for geothermal, nuclear and solar energy conversion. Compressor is one of the key components for the supercritical carbon dioxide Brayton cycle. With established or developing small power supercritical carbon dioxide test loop, centrifugal compressor with small mass flow rate is mainly investigated and manufactured in the literature; however, nuclear energy conversion contains more power, and axial compressor is preferred to provide SCO2 compression with larger mass flow rate which is less studied in the literature. The performance of the axial supercritical carbon dioxide compressor is investigated in the current work. An axial supercritical carbon dioxide compressor with mass flow rate of 1000kg/s is designed. The thermodynamic region of the carbon dioxide is slightly above the vapor-liquid critical point with inlet total temperature 310K and total pressure 9MPa. Numerical simulation is then conducted to assess this axial compressor with look-up table adopted to handle the nonlinear variation property of supercritical carbon dioxide near the critical point. The results show that the performance of the design point of the designed axial compressor matches the primary target. Small corner separation occurs near the hub, and the flow motion of the tip leakage fluid is similar with the well-studied air compressor. Violent property variation near the critical point creates troubles for convergence near the stall condition, and the stall mechanism predictions are more difficult for the axial supercritical carbon dioxide compressor.


Author(s):  
Byeung Jun Lim ◽  
Tae Choon Park ◽  
Young Seok Kang

In this study, characteristics of stall inception in a single-stage transonic axial compressor with circumferential grooves casing treatment were investigated experimentally. Additionally, the characteristic of increasing irregularity in the pressure inside circumferential grooves as the compressor approaches the stall limit was applied to the stall warning method. Spike-type rotating stall was observed in the single-stage transonic axial compressor with smooth casing. When circumferential grooves were applied, the stall inception was suppressed and the operating point of the compressor moved to lower flow rate than the stall limit. A spike-like disturbance was developed into a rotating stall cell and then the Helmholtz perturbation was overlapped on it at N = 80%. At N = 70 %, the Helmholtz perturbation was observed first and the amplitude of the wave gradually increased as mass flow rate decreased. At N = 60%, spike type stall inceptions were observed intermittently and then developed into continuous rotating stall at lower mass flow rate. Pressure measured at the bottom of circumferential grooves showed that the level of irregularity of pressure increased as flow rate decreased. Based on the characteristic of increasing irregularity of the pressure signals inside the circumferential grooves as stall approaches, an autocorrelation technique was applied to the stall warning. This technique could be used to provide warning against stall and estimate real-time stall margins in compressors with casing treatments.


2004 ◽  
Vol 126 (3) ◽  
pp. 333-338 ◽  
Author(s):  
Axel Fischer ◽  
Walter Riess ◽  
Joerg R. Seume

The FVV sponsored project “Bow Blading” (cf. acknowledgments) at the Turbomachinery Laboratory of the University of Hannover addresses the effect of strongly bowed stator vanes on the flow field in a four-stage high-speed axial compressor with controlled diffusion airfoil (CDA) blading. The compressor is equipped with more strongly bowed vanes than have previously been reported in the literature. The performance map of the present compressor is being investigated experimentally and numerically. The results show that the pressure ratio and the efficiency at the design point and at the choke limit are reduced by the increase in friction losses on the surface of the bowed vanes, whose surface area is greater than that of the reference (CDA) vanes. The mass flow at the choke limit decreases for the same reason. Because of the change in the radial distribution of axial velocity, pressure rise shifts from stage 3 to stage 4 between the choke limit and maximum pressure ratio. Beyond the point of maximum pressure ratio, this effect is not distinguishable from the reduction of separation by the bow of the vanes. Experimental results show that in cases of high aerodynamic loading, i.e., between maximum pressure ratio and the stall limit, separation is reduced in the bowed stator vanes so that the stagnation pressure ratio and efficiency are increased by the change to bowed stators. It is shown that the reduction of separation with bowed vanes leads to a increase of static pressure rise towards lower mass flow so that the present bow bladed compressor achieves higher static pressure ratios at the stall limit.


Author(s):  
Hongwei Ma ◽  
Jun Zhang

The purpose of this paper is to investigate numerically the effects of the tip geometry on the performance of an axial compressor rotor. There are three case studies which are compared with the base line tip geometry. 1) baseline (flat tip); 2) Cavity (tip with a cavity); 3) SSQA (suction side squealer tip) and 4) SSQB (modified suction side squealer tip). The case of SSQB is a combination of suction side squealer tip and the cavity tip. From leading edge to 10% chord, the tip has a cavity. From 10% chord to trailing edge, the tip has a suction side squealer. The numerical results of 2) show that the cavity tip leads to lower leakage mass flow and greater loss in tip gap and the rotor passage. The loading near the blade tip is lower than the baseline, thus the tangential force of the blade is lower. It leads to lower pressure rise than the baseline. The performance of the compressor for the tip with cavity is worse than the baseline. The results of 3) show that the higher curvature of the suction side squealer increases the loading of the blade and the tangential blade force. With the suction side squealer tip, the leakage flow experiences two vena contractor thus the mass of the leakage flow is reduced which is benefit for the performance of the compressor. The loss in the tip gap is lower than baseline. The performance is better than the baseline with greater pressure rise of the rotor, smaller leakage mass flow and lower averaged loss. For the case the SSQB, the leakage mass flow is lower than the SSQA and the loss in the tip gap and the rotor passage is greater than SSQA. The performance of the case of the SSQB is worse than the case of SSQA.


2014 ◽  
Vol 30 (3) ◽  
pp. 307-313 ◽  
Author(s):  
R. Taghavi-Zenou ◽  
S. Abbasi ◽  
S. Eslami

ABSTRACTThis paper deals with tip leakage flow structure in subsonic axial compressor rotor blades row under different operating conditions. Analyses are based on flow simulation utilizing computational fluid dynamic technique. Three different circumstances at near stall condition are considered in this respect. Tip leakage flow frequency spectrum was studied through surveying instantaneous static pressure signals imposed on blades surfaces. Results at the highest flow rate, close to the stall condition, showed that the tip vortex flow fluctuates with a frequency close to the blade passing frequency. In addition, pressure signals remained unchanged with time. Moreover, equal pressure fluctuations at different passages guaranteed no peripheral disturbances. Tip leakage flow frequency decreased with reduction of the mass flow rate and its structure was changing with time. Spillage of the tip leakage flow from the blade leading edge occurred without any backflow in the trailing edge region. Consequently, various flow structures were observed within every passage between two adjacent blades. Further decrease in the mass flow rate provided conditions where the spilled flow ahead of the blade leading edge together with trailing edge backflow caused spike stall to occur. This latter phenomenon was accompanied by lower frequencies and higher amplitudes of the pressure signals. Further revolution of the rotor blade row caused the spike stall to eventuate to larger stall cells, which may be led to fully developed rotating stall.


Author(s):  
Chihiro Myoren ◽  
Yasuo Takahashi ◽  
Manabu Yagi ◽  
Takanori Shibata ◽  
Tadaharu Kishibe

An axial compressor was developed for an industrial gas turbine equipped with a water atomization cooling (WAC) system, which is a kind of inlet fogging technique with overspray. The compressor performance was evaluated using a 40MW-class test facility for the advanced humid air turbine system. A prediction method to estimate the effect of WAC was developed for the design of the compressor. The method was based on a streamline curvature (SLC) method implementing a droplet evaporation model. Four test runs with WAC have been conducted since February 2012. The maximum water mass flow rate was 1.2% of the inlet mass flow rate at the 4th test run, while the design value was 2.0%. The results showed that the WAC decreased the inlet and outlet temperatures compared with the DRY (no fogging) case. These decreases changed the matching point of the gas turbine, and increased the mass flow rate and the pressure ratio by 1.8% and 1.1%, respectively. Since prediction results agreed with the results of the test run qualitatively, the compressor performance improvement by WAC was confirmed both experimentally and analytically. The test run with the design water mass flow rate is going to be conducted in the near future.


Author(s):  
Garth V. Hobson ◽  
Anthony J. Gannon ◽  
Scott Drayton

A new design procedure was developed that uses commercial-off-the-shelf software (MATLAB, SolidWorks, and ANSYS-CFX) for the geometric rendering and analysis of a transonic axial compressor rotor with splitter blades. Predictive numerical simulations were conducted and experimental data were collected in a Transonic Compressor Rig. This study advanced the understanding of splitter blade geometry, placement, and performance benefits. In particular, it was determined that moving the splitter blade forward in the passage between the main blades, which was a departure from the trends demonstrated in the few available previous transonic axial compressor splitter blade studies, increased the mass flow range with no loss in overall performance. With a large 0.91 mm (0.036 in) tip clearance, to preserve the integrity of the rotor, the experimentally measured peak total-to-total pressure ratio was 1.69 and the peak total-to-total isentropic efficiency was 72 percent at 100 percent design speed. Additionally, a higher than predicted 7.5 percent mass flow rate range was experimentally measured, which would make for easier engine control if this concept were to be included in an actual gas turbine engine.


1999 ◽  
Vol 121 (2) ◽  
pp. 365-375 ◽  
Author(s):  
H. M. Saxer-Felici ◽  
A. P. Saxer ◽  
A. Inderbitzin ◽  
G. Gyarmathy

This paper presents a parallel numerical and experimental study of rotating stall cells in an axial compressor. Based on previous theoretical and experimental studies stressing the importance of fluid inertia and momentum exchange mechanisms in rotating stall, a numerical simulation using the Euler equations is conducted. Unsteady two-dimensional solutions of rotating stall behavior are obtained in a one-stage low subsonic axial compressor. The structure and speed of propagation of one fully developed rotating stall cell together with its associated unsteady static pressure and throughflow field distributions are presented. The numerical capture of a stalled flow region starting from a stable high-flow operating point with an axisymmetric flow distribution and evolving at a reduced mass flow operating point into a rotating stall pattern is also discussed. The experimental data (flow visualization, time-averaged and unsteady row-by-row static pressure measurements) acquired in a four-stage water model of a subsonic axial compressor cover a complete characteristic line ranging from high mass flow in the stable regime to zero throughflow. Stall inception is presented together with clearly marked different operating zones within the unstable regime. For one operating point in the unstable regime, the speed of propagation of the cell as well as the static pressure spikes at the front and rear boundaries of the rotating stall cell are compared between computations, measurements, and an idealized theory based on momentum exchange between blade rows entering and leaving the stalled cell. In addition, the time evolution of the pressure trace at the rotor/stator interface is presented. This study seems to support the assumption that the cell structure and general mechanism of full-span rotating stall propagation are essentially governed by inertial effects and momentum exchange between the sound and stalled flow at the cell edges.


Sign in / Sign up

Export Citation Format

Share Document