scholarly journals Technology of Plasticity. Three-Dimensional FEM Analysis of Helical Gear Subjected to the Carburized Quenching Process.

2001 ◽  
Vol 50 (6) ◽  
pp. 598-605 ◽  
Author(s):  
Manabu FUKUMOTO ◽  
Masatoshi YOSHIZAKI ◽  
Hideki IMATAKA ◽  
Kazuo OKAMURA ◽  
Kenji YAMAMOTO
2004 ◽  
Vol 120 ◽  
pp. 489-497
Author(s):  
R. Mukai ◽  
D.-Y. Ju

Predictions of deformation, residual stresses and hardness after heat treatment of gears by numerical simulation are very useful to determine optimum condition to decrease the distortion of machinery parts. In this paper, simulation on carburizing quenching of a helical gear made of carbon steel SCr420 was carried out using three-dimensional coupled analysis based on thermo-mechanical theory considering phase transformation. The expansion and latent heat due to phase transformation at various carburizing conditions were measured by TMA and DSC to determine the thermal physical properties of SCr420 carbon steel. The influence of the transformation plasticity strain on deformation, residual stress and hardness of a gear was clarified in the simulation. The accuracy of simulation also is verified by the comparison between the experimental data and the simulated result of the distortion and residual stress. From the predicted results, improvement of the hardness and strength on surface of the gear due to the carburizing-quenching process can be verified.


2021 ◽  
Vol 11 (12) ◽  
pp. 5461
Author(s):  
Elmedin Mešić ◽  
Enis Muratović ◽  
Lejla Redžepagić-Vražalica ◽  
Nedim Pervan ◽  
Adis J. Muminović ◽  
...  

The main objective of this research is to establish a connection between orthodontic mini-implant design, pull-out force and primary stability by comparing two commercial mini-implants or temporary anchorage devices, Tomas®-pin and Perfect Anchor. Mini-implant geometric analysis and quantification of bone characteristics are performed, whereupon experimental in vitro pull-out test is conducted. With the use of the CATIA (Computer Aided Three-dimensional Interactive Application) CAD (Computer Aided Design)/CAM (Computer Aided Manufacturing)/CAE (Computer Aided Engineering) system, 3D (Three-dimensional) geometric models of mini-implants and bone segments are created. Afterwards, those same models are imported into Abaqus software, where finite element models are generated with a special focus on material properties, boundary conditions and interactions. FEM (Finite Element Method) analysis is used to simulate the pull-out test. Then, the results of the structural analysis are compared with the experimental results. The FEM analysis results contain information about maximum stresses on implant–bone system caused due to the pull-out force. It is determined that the core diameter of a screw thread and conicity are the main factors of the mini-implant design that have a direct impact on primary stability. Additionally, stresses generated on the Tomas®-pin model are lower than stresses on Perfect Anchor, even though Tomas®-pin endures greater pull-out forces, the implant system with implemented Tomas®-pin still represents a more stressed system due to the uniform distribution of stresses with bigger values.


2012 ◽  
Vol 178-181 ◽  
pp. 2373-2377 ◽  
Author(s):  
Wen Tsung Liu ◽  
Yi Yi Li

From the 921 earthquake to the major typhoons, including the Morakot typhoon, they damaged original landscape of rivers in Taiwan. In recent years, it alleged that abutment bridge exposed to the most serious security problems. Because of bridge piers in addition to the face of long-term river erosion, the flood on the pier will produce localized erosion near the bridge. The pier will be due to inadequate bearing capacity, resulting in subsidence, displacement, bridge version accompanied by tilting and even caving. The river erosion of soil around the piers deposits and production of contraction will often reduce the bearing capacity. Therefore, how to accurately estimate the scour depth, calculate piers to withstand water impact and analyses its stability for preventing injuries in the first place is the current pressing issues. In this study, three-dimensional finite element method (FEM) analysis program Plaxis 3D foundation is used. Polaris second bridge is selected for analysis. Based on local scouring of the model and various numerical variable conditions, the parameter of bridge pier is studied.


2012 ◽  
Vol 06 (01) ◽  
pp. 009-015 ◽  
Author(s):  
Didem Nalbantgil ◽  
Murat Tozlu ◽  
Fulya Ozdemir ◽  
Mehmet Oguz Oztoprak ◽  
Tulin Arun

ABSTRACTObjectives: Non-homogeneous force distribution along the miniplates and the screws is an unsolved question for skeletal anchorage in orthodontics. To overcome this issue, a miniplate structure was designed featuring spikes placed on the surface facing the cortical bone. The aim of this study was to examine and compare the force distribution of the newly designed plate-screw systems with the conventional one.Methods: A model of bone surface with 1.5 mm cortical thickness, along with the two newly designed miniplates and a standard miniplate-screw were simulated on the three-dimensional model. 200 g experimental force was applied to the tip of the miniplates and the consequential effects on the screws and cortical bone was evaluated using three-dimensional finite element method.Results: As a result of this finite element study, remarkably lower stresses were observed on the screws and the cortical bone around the screws with the newly designed miniplate when compared with the conventional one.Conclusion: The newly designed miniplate that has spikes was found effective in reducing the stress on and around the screws and the force was distributed more equivalently. (Eur J Dent 2012;6:9-15)


Sign in / Sign up

Export Citation Format

Share Document