scholarly journals Fault Analysis using SFCL in the Convertor System at the Load Line

2021 ◽  
pp. 60-67
Author(s):  
Suman Baghel ◽  
Sanjeev Jarring

Among many renewable energy sources, solar energy is considered one of the most promising resources for large-scale electricity generation. Here propose resistive SFCL if a fault occurs in a simple low voltage (LV) network. To assess the impact of SFCL in the power system under study, the space-time approach is used to evaluate the short-circuit current in force and spurious control strategies are suggested to achieve the goal. The results complement the feasibility of the proposed A-ACO-based rationalization control for transmission activity according to the limiting circuit and fault current analyzer. The second model of the bastard chassis concludes that the chassis with residual current limiting circuit and analyzer reduces the expansion of the residual current and prevents the voltage from dropping to zero, that no artificial and temporal innovation is used as before. Intelligence-based computer procedures further shorten the working time, which also makes the frame more efficient, as the voltage is restored to its typical value in a short time if the test frame is played for 1 second in a MATLAB climate / SIMULINK. The time taken by the ACO algorithm to restore normal operating conditions in the line was 0.197 seconds, 0.206 seconds and 0.27 seconds for LLLG, LLG and LG errors, respectively.

2013 ◽  
Vol 448-453 ◽  
pp. 1732-1737
Author(s):  
Liu Bin ◽  
Hong Wei Cui ◽  
Li Xu ◽  
Kun Wang ◽  
Zhu Zhan ◽  
...  

This paper analyses the characteristics of large-scale offshore wind farm collection network and the impact of the medium voltage collection system optimization,while from the electrical technology point,it proposes the short circuit current of the collection network computational model and algorithms,based on the principle of equivalent circuit.Taking a wind power coolection system planned for a certain offshore wind farm planning for example, the validity of the model and algorithm is verified.


2020 ◽  
Author(s):  
Paulo Andrade Souza ◽  
Renan R. dos Santos ◽  
Manoelito C. N. Filho ◽  
Daniel Barbosa ◽  
Luciano Sales Barros

Due to the increasing penetration of Renewable Energy Sources (RES) such as wind energy in electrical grids, Wind Energy Conversion Systems (WECS) participation in primary control is becoming required including the Doubly Fed Induction Generator (DFIG)-based WECS. High integration of large scale DFIG-based WECS brings new challenges to their primary control support, and more strongly due to the wind condition and grid parameter uncertainties. One of the most used types of control strategy for DFIG-based WECS primary support is the synthetic inertia, however, robustness of these techniques have not been tested. In this work three synthetic inertia control strategies will be tested under different operating conditions of wind speed, frequency and voltage sag. For testing the DFIG-based WECS, it was modeled on ATP including its control systems and the results quantified the controllers robustness on the tested controllers with respect to transient frequency behavior.


Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 156 ◽  
Author(s):  
Saba Gul ◽  
Azhar Ul Haq ◽  
Marium Jalal ◽  
Almas Anjum ◽  
Ihsan Ullah Khalil

Fault analysis in photovoltaic (PV) arrays is considered important for improving the safety and efficiency of a PV system. Faults do not only reduce efficiency but are also detrimental to the life span of a system. Output can be greatly affected by PV technology, configuration, and other operating conditions. Thus, it is important to consider the impact of different PV configurations and materials for thorough analysis of faults. This paper presents a detailed investigation of faults including non-uniform shading, open circuit and short circuit in different PV interconnections including Series-Parallel (SP), Honey-Comb (HC) and Total-cross-Tied (TCT). A special case of multiple faults in PV array under non-uniform irradiance is also investigated to analyze their combined impact on considered different PV interconnections. In order to be more comprehensive, we have considered monocrystalline and thin-film PV to analyze faults and their impact on power grids. Simulations are conducted in MATLAB/Simulink, and the obtained results in terms of power(P)–voltage(V) curve are compared and discussed. It is found that utilization of thin-film PV technology with appropriated PV interconnections can minimize the impact of faults on a power grid with improved performance of the system.


2013 ◽  
Vol 860-863 ◽  
pp. 1914-1918
Author(s):  
Yi Rong Su ◽  
Jie Yu ◽  
Jun Liu ◽  
Gan Zhou ◽  
Li Ping Zhan ◽  
...  

In order to improve the level of automation and security of the low voltage power supply system, this paper proposed the calculation method of short-circuit current criterion under condition of protection action. Firstly, the impact of circuit breakers on the short-circuit current is analyzed. Then, the current criterion under condition of short-circuit protection are given. Finally, using a special case, the calculation process of aforementioned current criterion is given in detail.


2013 ◽  
Vol 479-480 ◽  
pp. 559-564
Author(s):  
Cheng Ting Hsu ◽  
Chao Shun Chen ◽  
Chia Hung Lin ◽  
Tsun Jen Cheng

This paper investigates the impact of photovoltaic generation system (pvgs) on the distribution system. The installations of various types of distributed generators (dgs) on the distribution system have significantly changed the operating, planning and maintaining strategies of the utility. In this paper, one practical Taiwan Power Company (taipower) distribution system with a large-scale of pvgs is selected for study. Many power quality issues like steady state voltage variation, reverse power, voltage unbalance, short-circuit current and harmonic are analyzed by considering many different operation scenarios of the distribution system and pvgs. The simulation results are compared with the related standards and it is found that the pvgs impact on the concerned power quality and reliability issues are all within the limits. It is concluded that the simulation results of the paper are very helpful to the electric utilities and pv producers for providing better power quality as well as increasing photovoltaic (pv) penetration in distribution grids.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xi Huo ◽  
Jing Chen ◽  
Shigui Ruan

Abstract Background The COVID-19 outbreak in Wuhan started in December 2019 and was under control by the end of March 2020 with a total of 50,006 confirmed cases by the implementation of a series of nonpharmaceutical interventions (NPIs) including unprecedented lockdown of the city. This study analyzes the complete outbreak data from Wuhan, assesses the impact of these public health interventions, and estimates the asymptomatic, undetected and total cases for the COVID-19 outbreak in Wuhan. Methods By taking different stages of the outbreak into account, we developed a time-dependent compartmental model to describe the dynamics of disease transmission and case detection and reporting. Model coefficients were parameterized by using the reported cases and following key events and escalated control strategies. Then the model was used to calibrate the complete outbreak data by using the Monte Carlo Markov Chain (MCMC) method. Finally we used the model to estimate asymptomatic and undetected cases and approximate the overall antibody prevalence level. Results We found that the transmission rate between Jan 24 and Feb 1, 2020, was twice as large as that before the lockdown on Jan 23 and 67.6% (95% CI [0.584,0.759]) of detectable infections occurred during this period. Based on the reported estimates that around 20% of infections were asymptomatic and their transmission ability was about 70% of symptomatic ones, we estimated that there were about 14,448 asymptomatic and undetected cases (95% CI [12,364,23,254]), which yields an estimate of a total of 64,454 infected cases (95% CI [62,370,73,260]), and the overall antibody prevalence level in the population of Wuhan was 0.745% (95% CI [0.693%,0.814%]) by March 31, 2020. Conclusions We conclude that the control of the COVID-19 outbreak in Wuhan was achieved via the enforcement of a combination of multiple NPIs: the lockdown on Jan 23, the stay-at-home order on Feb 2, the massive isolation of all symptomatic individuals via newly constructed special shelter hospitals on Feb 6, and the large scale screening process on Feb 18. Our results indicate that the population in Wuhan is far away from establishing herd immunity and provide insights for other affected countries and regions in designing control strategies and planing vaccination programs.


Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2427
Author(s):  
Michał Szulborski ◽  
Sebastian Łapczyński ◽  
Łukasz Kolimas

The manuscript presents advanced coupled analysis: Maxwell 3D, Transient Thermal and Fluent CFD, at the time of a rated current occurring on the main busbars in the low-voltage switchgear. The simulations were procured in order to aid the design process of such enclosures. The analysis presented the rated current flow in the switchgear busbars, which allowed determining their temperature values. The main assumption of the simulation was measurements of temperature rise during rated current conditions. Simulating such conditions is a valuable asset in order to design better solutions for energy distribution gear. The simulation model was a precise representation of the actual prototype of the switchgear. Simulations results were validated by experimental research. The heat dissipation in busbars and switchgear housing through air convection was presented. The temperature distribution for the insulators in the rail bridge made of fireproof material was considered: halogen-free polyester. The results obtained during the simulation allowed for a detailed analysis of switchgear design and proper conclusions in practical and theoretical aspects. That helped in introducing structural changes in the prepared prototype of the switchgear at the design and construction stages. Deep analysis of the simulation results allowed for the development concerning the final prototype of the switchgear, which could be subjected to the full type tests. Additionally, short-circuit current simulations were procured and presented.


Sign in / Sign up