scholarly journals Numerical studies on vibration propagation and damping test V1

2018 ◽  
Vol 51 (1) ◽  
pp. 55-80 ◽  
Author(s):  
Arja Saarenheimo ◽  
Michael Borgerhoff ◽  
Kim Calonius ◽  
Anthony Darraba ◽  
Alexandre Hamelin ◽  
...  

Earthquakes and aircraft impacts induce vibrations that propagate throughout the entire building and they need to be considered in designing SSCs (Structures, Systems and Components). Mainly linear calculation methods have been in use in design practice and the codes and standards consider damping ratios only for linear structural analyses. Induced vibrations, especially in damaged concrete structures, have not been studied extensively enough for optimization of structural frameworks and/or qualified systems and components. Experimental data on damping properties of damaged reinforced concrete are needed also for benchmarking analysis programs and methods. Recently, within IMPACT project, a new type of test series considering vibration propagation has been carried out at VTT. The test target is a reinforced concrete structure with two parallel walls connected to a floor slab. The front wall is additionally supported by triangular shaped side walls which are connected to the floor slab too. The test structure is supported on elastomeric bearing pads, with back pipes effective mainly in compression and with bars effective in tension. In order to obtain information on vibration propagation in damaged concrete structure at different levels of damage grades the same structure was tested six times. At each time the mass of the deformable stainless steel missile was 50 kg. The hit point located in the middle of the front wall. The impact velocity was about 110 m/s in the first four tests (V1A-D) and about 60 m/s in the remaining two tests (V1E and F). In this paper, numerical results on tests V1A and V1F are compared with the corresponding experimental ones. The calculated results, such as accelerations, displacements, their response spectra and strains, are compared with experimental measurements. Five finite element (FE) programs are used in computations: Abaqus, Europlexus, LS-DYNA, SOFiSTiK and an in-house code (IHC). Most of the FE-codes in the present study use shell elements. In Abaqus and SOFiSTiK non-linear behaviour of shell section is modelled by dividing the cross section into layers. Reinforcements are also modelled as layers. In Europlexus and IHC, an alternative approach is adopted in which the non-linear behaviour of concrete and reinforcement is homogenized beforehand in the shell thickness direction obtaining relations between stress resultants and generalized strains valid for the shell section. In LS-DYNA, 3D solid elements for modelling concrete and beam elements for modelling reinforcements are used. Equations of motion are integrated with explicit central difference time integration method, except in SOFiSTiK implicit integration method is used. Modelling and computations with the mentioned FE-programs are made independently of each other. Computations with LS-DYNA are carried out as blind exercises. Consideration of the results from benchmarking point of view is still on-going. However it is evident that analysed results follow reasonable well test results in main design parameter level such as maximum displacements, accelerations and strains. Also frequency spectra are estimated reasonably well.

2010 ◽  
Vol 36 ◽  
pp. 176-181
Author(s):  
Xian Feng He ◽  
Shou Gang Zhao ◽  
Yuan Bao Leng

The corrosion of steel will have a bad impact on the safety of reinforced concrete structure. In severe cases, it may even be disastrous. In order to understand the impact of steel corrosion on the structure, tests are carried out to study corrosion and expansion rules of steel bars as well as the impact rules of corrosion on bond force between steel and concrete. The results show that wet and salty environment will result in steel corrosion; relatively minor corrosion will not cause expansion cracks of protection layers; when steel rust to a certain extent, it will cause cracks along the protection layer; when there exists minor corrosion in steel and the protection layer does not have expansion cracks, the bond force is still large and rapidly decreases as the corrosion rate increases.


Author(s):  
Mikhail Sainov

Introduction. The main factor determining the stress-strain state (SSS) of rockfill dam with reinforced concrete faces is deformability of the dam body material, mostly rockfill. However, the deformation properties of rockfill have not been sufficiently studied yet for the time being due to technical complexity of the matter, Materials and methods. To determine the deformation parameters of rockfill, scientific and technical information on the results of rockfill laboratory tests in stabilometers were collected and analyzed, as well as field data on deformations in the existing rockfill dams. After that, the values of rockfill linear deformation modulus obtained in the laboratory and in the field were compared. The laboratory test results were processed and analyzed to determine the parameters of the non-linear rockfill deformation model. Results. Analyses of the field observation data demonstrates that the deformation of the rockfill in the existing dams varies in a wide range: its linear deformation modulus may vary from 30 to 500 МPа. It was found out that the results of the most rockfill tests conducted in the laboratory, as a rule, approximately correspond to the lower limit of the rockfill deformation modulus variation range in the bodies of the existing dams. This can be explained by the discrepancy in density and particle sizes of model and natural soils. Only recently, results of rockfill experimental tests were obtained which were comparable with the results of the field measurements. They demonstrate that depending on the stress state the rockfill linear deformation modulus may reach 700 МPа. The processing of the results of those experiments made it possible to determine the parameters on the non-linear model describing the deformation of rockfill in the dam body. Conclusions. The obtained data allows for enhancement of the validity of rockfill dams SSS analyses, as well as for studying of the impact of the non-linear character of the rockfill deformation on the SSS of reinforced concrete faces of rockfill dams.


Author(s):  
Genadijs Sagals ◽  
Nebojsa Orbovic ◽  
Thambiayah Nitheanandan

Abstract This paper describes the work conducted by the Canadian Nuclear Safety Commission (CNSC) related to the numerical simulations of reinforced concrete (RC) structures under deformable missile impact. The current paper is a continuation of the work conducted in the frame of the OECD/NEA* IRIS (Improving Robustness Assessment Methodologies for Structures Impacted by Missiles) Phase 3 benchmark project. The concrete mock-up with two simple structures attached, one welded and another bolted, was built and tested at the VTT Technical Research Centre in Espoo, Finland. This mock-up was impacted by three subsequent missiles with varying velocities in order to obtain the damage accumulation. To examine vibration transmission through the mock-up, the simple structures modelling equipment were attached to the rear wall of the structure, while the missile impact was at the centre of the front wall. The parameters of the missiles and the RC structure were selected to ensure a flexible behaviour of the RC target in the impact area with only moderate damages, specifically cracking and permanent deformation without perforation. The non-linear dynamic behaviour of the reinforced concrete slabs under missile impact was analyzed using the commercial FE code LS-DYNA. A hybrid FE model using both 3-D solid and 2-D shell FE models was developed for the target discretization. Since the ultimate objective of this work is to model the entire structure over long time periods, a simplified combined shell-solid model with distributed (smeared) reinforcement was selected and validated. This model employs solid FE around an impact area and shell FE for the rest of the mock-up. Detailed modelling of a large RC structure with all equipment attached leads to a very large finite element (FE) model. Therefore, two-level FE modelling using sub-modelling approach was employed: first, analyze the vibrations of a reinforced concrete structure with simplified equipment modelling, and second, analyze in detail the equipment connected to it. This approach assumes uncoupled dynamic behaviour of the structure and the equipment. While the sub-modelling technique is commonly used in static analysis, a special sensitivity analysis was conducted to prove the applicability of sub-modelling for impact analysis. Finally, the effect of structural damping was examined and the best possible damping was selected. The selected damping values and sub-models resulted in relatively good agreement with the test results for both global (RC mock-up) and local (equipment) behaviour.


Author(s):  
Oleg Rubin ◽  
Anton Antonov ◽  
Sergey Lisichkin ◽  
Kirill Frolov ◽  
Andrey Lisichkin

Introduction. Floorings of the turbine hall and installation sites of the HPP (PSS) are one of the most important reinforced concrete structures, as during operation they are subjected to significant process duties, including those not provided for by the project. Thus, during the testing of crane equipment on the floor surface of the installation site of the Alluriquin HPP under construction, the cargo weighing 22 tons fell, under the influence of which the floor slab was punched, which required a comprehensive study of the condition of the reinforced concrete structure of the floor and the surrounding area of the failure of structures, as well as the development of measures to strengthen the damaged structure. Materials and Methods. Visual and instrumental studies of the stress and strain state (SSS) of the reinforced concrete structure of the turbine hall slab and surrounding structures were carried out with the use of optical devices (MPB-3 reading microscope), Schmidt hammer to determine the strength of concrete structures, as well as the “reinforcement load removal” method to determine the actual stresses in the reinforcement of structures. Results. The punching of the reinforced concrete floor of the installation site with vertical displacements of the edges of through cracks up to 12 mm, as well as the system of cracks formed during the fall of cargo was revealed. The actual stresses in the reinforcement are determined by the “reinforcement load removal” method. On the basis of finite element modeling the actual condition of structures during the period of cargo fall and after the removal of the load is obtained. On the basis of the analysis of results of field and design studies the schematic diagram of strengthening of structures by carbon composite materials is developed. Conclusions. The actual SSS of the reinforced concrete floor of the installation site and its support structures during the period of the cargo fall and after the termination of the impulse load is established. The vertical displacement of the edges of the crack of the floor punching was 17.5 mm during the period of the fall of the load and 12 mm after the removal of the impulse load. Crack opening width in reinforced concrete structures in the cargo drop area reached 2 mm. At the moment when the cargo fell on the floor slab, the values of stresses in the reinforcement cage reached 200 MPa; after the impact — 76.2 MPa. With a view of the subsequent safe operation of the reinforced concrete floor and surrounding structures the basic schemes of their strengthening by external reinforcement on the basis of carbon fiber have been developed, which have been proved by calculation.


2019 ◽  
Vol 2019 ◽  
pp. 1-16 ◽  
Author(s):  
Xiwu Zhou ◽  
Runcheng Zhang ◽  
Ruisheng Xiong ◽  
Guoxue Zhang ◽  
Xiangyu Wang

The reinforced concrete structure of a port wharf is affected by steel corrosion and ship docking impact. Replacing an ordinary steel bar with a stainless steel bar can solve the corrosion problem of the steel bar while ensuring the bearing capacity of the structure. However, the research on impact resistance of stainless steel-reinforced concrete structure is not perfect. In this paper, impact mechanical properties of reinforced concrete beams before and after equal strength replacement of stainless steel bars are analyzed by theoretical analysis and drop hammer impact test, and the possibility and applicable scope of equal strength replacement of stainless steel bars are put forward. The results indicated the following: (1) when the reinforcement ratios were small (0.21% to 1.32%), the stainless steel-reinforced concrete beams with equal strength were able to effectively reduce the stiffness losses of the beams undergoing impact loads, as well as improve the elastic resilience abilities, and reduce the structural damages. Therefore, the corrosion and impact problems of reinforcements could be solved by replacing ordinary reinforcements with stainless steel reinforcements and (2) when the reinforcement ratios were large (1.32% to 2.57%), the shear failures of the stainless steel-reinforced concrete beams were observed to be relatively serious, and the impact resistance performances had worsened. The research results provide technical support for the engineering application of stainless steel-reinforced concrete structure design.


Sign in / Sign up

Export Citation Format

Share Document