Effect of Sonic Resin Composite Delivery on Void Formation Assessed by Micro-computed Tomography

2018 ◽  
Vol 43 (2) ◽  
pp. 144-150 ◽  
Author(s):  
R Hirata ◽  
RR Pacheco ◽  
E Caceres ◽  
MN Janal ◽  
MF Romero ◽  
...  

SUMMARY Objectives: The aim of this study was to quantify the internal void volume formation in commercially available, resin composites inserted using conventional or sonic insertion methods, and analyzed using three-dimensional (3D) micro-computed tomography (μCT). Methods and Materials: Four resin composites were evaluated: one conventional (Herculite, Ultra, Kerr Corporation, Orange, CA, USA), one flowable bulk fill (SureFil SDR Flow, Dentsply International, York, PA, USA), and two packable bulk fill (SonicFill, Kerr Corporation, and Tetric EvoCeram Bulk Fill, Ivoclar Vivadent Inc, Schaan, Liechtenstein). Eight groups were evaluated according to each resin composite type and insertion method (conventional or sonic; n=5). Forty ABS 3D-printed cylindrical molds, 5.0 mm in diameter and 4.0 mm in depth, were fabricated. For the conventional resin composite, the mold was filled incrementally (two layers), while for bulk-fill resin composites, insertion was performed in a single increment. The sonic insertion method was performed using a specific handpiece (SonicFill Handpiece, Kerr Corporation). Resin composites were light cured using a multipeak light-emitting diode light-curing unit (VALO, Ultradent Products Inc, South Jordan, UT, USA) in its regular mode. Samples were evaluated by μCT, and data were imported into software (Amira, version 5.5.2, VSG, Burlington, MA, USA) for 3D reconstruction, from which the percentage of void volume was calculated. Data were analyzed using two-way analysis of variance and Tukey post hoc test at a preset alpha of 0.05. Results: The conventional insertion method resulted in reduced porosity, compared with sonic insertion, for SureFil SDR Flow and Tetric EvoCeram bulk fill. The sonic insertion method did not demonstrate any influence on void formation for Herculite Ultra or SonicFill. Conclusion: Results suggest that the sonic insertion method might increase void formation during resin composite delivery, depending on restorative material brand.

2018 ◽  
Vol 40 (8) ◽  
pp. 2984-2992 ◽  
Author(s):  
Gülbike Demirel ◽  
İsmail Hakkı Baltacıoğlu ◽  
Mehmet Eray Kolsuz ◽  
Mert Ocak ◽  
Kaan Orhan

2014 ◽  
Vol 39 (2) ◽  
pp. 174-180 ◽  
Author(s):  
XY Zhao ◽  
SB Li ◽  
LJ Gu ◽  
Y Li

SUMMARY This in vitro study evaluated the efficacy of micro–computed tomography (CT) in marginal leakage detection of Class V restorations. Standardized Class V preparations with cervical margins in dentin and occlusal margins in enamel were made in 20 extracted human molars and restored with dental bonding agents and resin composite. All teeth were then immersed in 50% ammoniacal silver nitrate solution for 12 hours, followed by a developing solution for eight hours. Each restoration was scanned by micro-CT, the depth of marginal silver leakage in the central scanning section was measured, and the three-dimensional images of the silver leakage around each restoration were reconstructed. Afterward, all restorations were cut through the center and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by the micro-CT and the microscope were compared for equivalency. The silver leakage depth in cervical walls observed by micro-CT and microscope showed no significant difference; however, in certain cases the judgment of leakage depth in the occlusal wall in micro-CT image was affected by adjacent enamel structure, providing less leakage depth than was observed with the microscope (p<0.01). Micro-CT displayed the three-dimensional image of the leakage around the Class V restorations with clear borders only in the dentin region. It can be concluded that micro-CT can detect nondestructively the leakage around a resin composite restoration in two and three dimensions, with accuracy comparable to that of the conventional microscope method in the dentin region but with inferior accuracy in the enamel region.


2021 ◽  
pp. 105566562110363
Author(s):  
Jiuli Zhao ◽  
Hengyuan Ma ◽  
Yongqian Wang ◽  
Tao Song ◽  
Chanyuan Jiang ◽  
...  

Objective Palatoplasty would involve the structures around the pterygoid hamulus. However, clinicians hold different opinions on the optimal approach for the muscles and palatine aponeurosis around the pterygoid hamulus. The absence of a consensus regarding this point can be attributed to the lack of investigations on the exact anatomy of this region. Therefore, we used micro-computed tomography to examine the anatomical structure of the region surrounding the pterygoid hamulus. Design Cadaveric specimens were stained with iodine–potassium iodide and scanned by micro-computed tomography to study the structures of the tissues, particularly the muscle fibers. We imported Digital Imaging and Communications in Medicine images to Mimics to reconstruct a 3-dimensional model and simplified the model. Results Three muscles were present around the pterygoid hamulus, namely the palatopharyngeus (PP), superior constrictor (SC), and tensor veli palatini (TVP). The hamulus connects these muscles as a key pivot. The TVP extended to the palatine aponeurosis, which bypassed the pterygoid hamulus, and linked the PP and SC. Some muscle fibers of the SC originated from the hamulus, the aponeurosis of which was wrapped around the hamulus. There was a distinct gap between the pterygoid hamulus and the palatine aponeurosis. This formed a pulley-like structure around the pterygoid hamulus. Conclusions Transection or fracture of the palatine aponeurosis or pterygoid hamulus, respectively, may have detrimental effects on the muscles around the pterygoid hamulus, which play essential roles in the velopharyngeal function and middle ear ventilation. Currently, cleft palate repair has limited treatment options with proven successful outcomes.


2013 ◽  
Vol 7 (1) ◽  
pp. 47-54 ◽  
Author(s):  
Emi Yamashita-Mikami ◽  
Mikako Tanaka ◽  
Naoki Sakurai ◽  
Kazuho Yamada ◽  
Hayato Ohshima ◽  
...  

The subject was a 53-year-old male. An alveolar bone sample was obtained from the site of the lower left first molar, before dental implant placement. Although the details of the trabecular structure were not visible with conventional computed tomography, micro-computed tomography (microCT) three-dimensional images of the alveolar bone biopsy sample showed several plate-like trabeculae extending from the lingual cortical bone. Histological observations of the bone sample revealed trabeculae, cuboidal osteoblasts, osteoclasts and hematopoietic cells existing in the bone tissue at the implantation site. Bone metabolic markers and calcaneal bone density were all within normal ranges, indicating no acceleration of the patient’s bone metabolism.Using microCT, and histological and histomorphometrical techniques, a great deal of valuable information about the bone tissue was obtained from a biopsy sample extracted from the patient’s planned implant site.


2014 ◽  
Vol 695 ◽  
pp. 588-591
Author(s):  
Khairul Salleh Basaruddin ◽  
Ruslizam Daud

This study aims to investigate the influence of trabecular bone in human mandible bone on the mechanical response under implant load. Three dimensional voxel finite element (FE) model of mandible bone was reconstructed from micro-computed tomography (CT) images that were captured from bone specimen. Two FE models were developed where the first consists of cortical bone, trabecular bone and implants, and trabecular bone part was excluded in the second model. A static analysis was conducted on both models using commercial software Voxelcon. The results suggest that trabecular bone contributed to the strength of human mandible bone and to the effectiveness of load distribution under implant load.


2021 ◽  
Vol 8 (11) ◽  
Author(s):  
Matthew J. Lawson ◽  
Orestis L. Katsamenis ◽  
David Chatelet ◽  
Aiman Alzetani ◽  
Oliver Larkin ◽  
...  

Micro-computed tomography (µCT) provides non-destructive three-dimensional (3D) imaging of soft tissue microstructures. Specific features in µCT images can be identified using correlated two-dimensional (2D) histology images allowing manual segmentation. However, this is very time-consuming and requires specialist knowledge of the tissue and imaging modalities involved. Using a custom-designed µCT system optimized for imaging unstained formalin-fixed paraffin-embedded soft tissues, we imaged human lung tissue at isotropic voxel sizes less than 10 µm. Tissue sections were stained with haematoxylin and eosin or cytokeratin 18 in columnar airway epithelial cells using immunofluorescence (IF), as an exemplar of this workflow. Novel utilization of tissue autofluorescence allowed automatic alignment of 2D microscopy images to the 3D µCT data using scripted co-registration and automated image warping algorithms. Warped IF images, which were accurately aligned with the µCT datasets, allowed 3D segmentation of immunoreactive tissue microstructures in the human lung. Blood vessels were segmented semi-automatically using the co-registered µCT datasets. Correlating 2D IF and 3D µCT data enables accurate identification, localization and segmentation of features in fixed soft lung tissue. Our novel correlative imaging workflow provides faster and more automated 3D segmentation of µCT datasets. This is applicable to the huge range of formalin-fixed paraffin-embedded tissues held in biobanks and archives.


2021 ◽  
Author(s):  
Paul M. Gignac ◽  
Haley D. O’Brien ◽  
Jimena Sanchez ◽  
Dolores Vazquez Sanroman

Abstract Advancements in tissue visualization techniques have spurred significant gains in the biomedical sciences by enabling researchers to integrate their datasets across anatomical scales. Of particular import are techniques that enable the interpolation of multiple hierarchical scales in samples taken from the same individuals. This study demonstrates that two-dimensional histology techniques can be employed on neural tissues following three-dimensional diffusible iodine-based contrast-enhanced computed tomography (diceCT) without causing tissue degradation. This represents the first step toward a multiscale pipeline for brain visualization. We studied brains from adolescent male Sprague-Dawley rats, comparing experimental (diceCT-stained then de-stained) to control (without diceCT) brains to evaluate neural tissues for immunolabeling integrity, compare somata sizes, and distinguish neurons from glial cells within the telencephalon and diencephalon. We hypothesized that if experimental and control samples do not differ significantly in quantitative metrics, brain tissues are robust to the chemical, temperature, and radiation environments required for these multiple, successive imaging protocols. Visualizations for experimental brains were first captured via micro-computed tomography scanning of isolated, iodine-infused specimens. Samples were then cleared of iodine, serially sectioned, and prepared again using immunofluorescent, fluorescent, and cresyl violet labeling, followed by imaging with confocal and light microscopy, respectively. Our results show that many neural targets are resilient to diceCT imaging and compatible with downstream histological staining as part of a low-cost, multiscale brain imaging pipeline.


2019 ◽  
Vol 31 (2) ◽  
pp. 236-241
Author(s):  
Aws ArRejaie ◽  
Saleh A. Alsuliman ◽  
Mohammed O. Aljohani ◽  
Hesham A. Altamimi ◽  
Emad Alshwaimi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document