Influence of Radiopacity of Dental Composites on the Diagnosis of Secondary Caries: The Correlation Between Objective and Subjective Analyses

2014 ◽  
Vol 39 (1) ◽  
pp. 90-97 ◽  
Author(s):  
AD Cruz ◽  
RG Esteves ◽  
IAVP Poiate ◽  
PP Portero ◽  
SM Almeida

SUMMARY This study aimed to objectively evaluate the radiopacity of different dental composites and their subjective influence on diagnosing secondary caries–like lesions and how these results correlate. For objective analysis, three resin specimens (1 mm thick, with a 4-mm internal diameter) were made with four composites: 1) Charisma; 2) Filtek Z250; 3) Prisma AP.H; and 4) Glacier. Three human teeth were selected and then mesio-distally sectioned (1 mm thick) to make the dental specimens. An aluminum (Al) wedge (12 steps, 1 mm thick, 99.8% purity) was used as an internal standard to calculate the radiopacity. For subjective analysis, 20 human teeth were selected and then prepared with a mesio-occluso-distal (MOD) inlay cavity, with half the teeth receiving a round cavity to simulate the carious lesion. The MOD was restored using the composites at four different times. Standardized radiographs were acquired and then digitized (300 dpi and eight-bit TIFF) for both analyses. A histogram objectively measured the pixel intensity values of the images, which were converted into millimeters of Al using linear regressions. Eight observers subjectively evaluated the images using a five-point rating scale to diagnose the caries. The data were statistically analyzed using the Student t-test, the Kappa test, diagnostic testing, and the Pearson correlation coefficient (α=0.05). All materials showed radiopacity values compatible with dental tissues (p>0.05); Glacier was similar to dentin and Prisma AP.H was similar to enamel, while the remaining materials showed a middle radiopacity. Prisma AP.H and Glacier differed (p<0.05) in relation to their accuracy to caries diagnosis, with Glacier having greater accuracy. There was a correlation between objective and subjective analyses with negative linear dependence. An increase in the material's radiopacity could have a subjectively negative influence on the diagnosis of secondary caries; thus, an ideal radiopacity for a dental composite is closer to the dentin image and produces similar attenuation to X-rays than does dentin.

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xuetao Zhou ◽  
Dongsheng Zhang ◽  
Zexin Xie ◽  
Yang Yang ◽  
Menghui Chen ◽  
...  

Abstract Objective To explore the clinical effect of 3D printing combined with framework internal fixation technology on the minimally invasive internal fixation of high complex rib fractures. Methods Total 16 patients with high complex rib fractures were included in the study. Before the procedure, the 3D rib model was reconstructed based on the thin-layer chest CT scan. According to the 3D model, the rib locking plate was pre-shaped, and the preoperative planning were made including the direction of the locking plate, the location of each nail hole and the length of the screw. During the operation, the locking plate was inserted from the sternum to the outermost fracture lines of ribs with screws at both ends. In addition, the locking plate was used as the frame to sequentially reduce the middle fracture segment and fix with screws or steel wires. Chest x-rays or chest CT scans after surgery were used to assess the ribs recovery. All patients were routinely given non-steroidal anti-inflammatory drugs (NSAIDS) for analgesia, and the pain level was evaluated using numerical rating scale (NRS). Results The preoperative planning according to the 3D printed rib model was accurate. The reduction and fixation of each fracture segment were successfully completed through the framework internal fixation technology. No cases of surgical death, and postoperative chest pain was significantly alleviated. Five to 10 months follow up demonstrated neither loosening of screws, nor displacement of fixtures among patients. The lungs of each patients were clear and in good shape. Conclusion The application of 3D printing combined with framework internal fixation technology to the high complex rib fractures is beneficial for restoring the inherent shape of the thoracic cage, which can realize the accurate and individualized treatment as well as reduces the operation difficulty.


Biomolecules ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1133
Author(s):  
Kevin Adi Kurnia ◽  
Fiorency Santoso ◽  
Bonifasius Putera Sampurna ◽  
Gilbert Audira ◽  
Jong-Chin Huang ◽  
...  

Tail coiling is a reflection response in fish embryos that can be used as a model for neurotoxic analysis. The previous method to analyze fish tail coiling is largely based on third-party software. In this study, we aim to develop a simple and cost-effective method called TCMacro by using ImageJ macro to reduce the operational complexity. The basic principle of the current method is based on the dynamic change of pixel intensity in the region of interest (ROI). When the fish tail is moving, the average intensity is increasing. In time when the fish freeze, the peak of mean intensity is maintaining at a relatively low level. By using the optimized macro settings and excel VBA scripts, all the tail coiling measurement processes can be archived with few operation steps with high precision. Three major endpoints of tail coiling counts, tail coiling duration and tail coiling intervals can be obtained in batch. To validate this established method, we tested the potential neurotoxic activity of Tricaine (methanesulfonate, MS-222) and psychoactive compound of caffeine. Zebrafish embryos after Tricaine exposure displayed significantly less tail coiling activity in a dose-dependent manner, and were comparable to manual counting through the Wilcoxon test and Pearson correlation double validation. Zebrafish embryos after caffeine exposure displayed significantly high tail coiling activity. In conclusion, the TCMacro method presented in this study provides a simple and robust method that is able to measure the relative tail coiling activities in zebrafish embryos in a high-throughput manner.


2011 ◽  
Vol 22 (2) ◽  
pp. 129-133 ◽  
Author(s):  
Patrícia Lima Moreira ◽  
Michel Reis Messora ◽  
Stela Márcia Pereira ◽  
Solange Maria de Almeida ◽  
Adriana Dibo da Cruz

The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (Az), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (Az=0.66, Filtek-Z250>Az=0.56, TPH-Spectrum) compared to 0º (Az=0.55, Charisma>Az=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.


2017 ◽  
Vol 23 (13) ◽  
pp. 1578-1591 ◽  
Author(s):  
David R. Coghill ◽  
Alain Joseph ◽  
Vanja Sikirica ◽  
Mark Kosinski ◽  
Caleb Bliss ◽  
...  

Objective: To assess relationships between treatment-associated changes in measures of ADHD symptoms, functional impairments, and health-related quality of life in children and adolescents with ADHD. Method: Pearson correlation coefficients were calculated post hoc for changes from baseline to endpoint in outcomes of one randomized, placebo- and active-controlled trial of lisdexamfetamine (osmotic-release methylphenidate reference) and one of guanfacine extended-release (atomoxetine reference). Results: Changes in ADHD Rating Scale IV (ADHD-RS-IV) total score generally correlated moderately with changes in Child Health and Illness Profile−Child Edition: Parent Report Form (CHIP-CE:PRF) Achievement and Risk Avoidance ( r ≈ .4), but weakly with Resilience, Satisfaction, and Comfort ( r ≈ .2); and moderately with Weiss Functional Impairment Rating Scale–Parent (WFIRS-P) total score ( r ≈ .5). CHIP-CE:PRF Achievement and Risk Avoidance correlated moderately to strongly with WFIRS-P total score ( r ≈ .6). Conclusion: The ADHD-RS-IV, CHIP-CE:PRF, and WFIRS-P capture distinct but interconnected aspects of treatment response in individuals with ADHD.


2021 ◽  
Vol 15 (1) ◽  
pp. 9-12
Author(s):  
Ameer Hamza Mahmood-ul-Hassan ◽  
Abdul Sannan ◽  
Nehala Nooz ◽  
Ansa Ramay ◽  
Muhammad Huzaifa ◽  
...  

Background: The world is facing COVID-19 pandemic and almost 70% of the world had gone under Lockdown. People are facing stress, insomnia and anxiety. The lack of basic awareness and spread of fake news are common causes of all these issues. This study was done to determine the prevalence of insomnia and anxiety in medical and non-medical students. Subjects and methods: Subjects were approached through friends in universities using WhatsApp. People having insomnia and anxiety before quarantine were excluded from this study. People using anti-depressants and anti-psychotics before quarantine were also excluded from this study. A descriptive cross-sectional study was conducted among 965 students of medical and non-medical universities in the cities of Lahore, Rawalpindi and Islamabad. Consent was taken for using the Hamilton Anxiety Rating Scale and Insomnia Severity Index for scoring of anxiety and insomnia respectively. An online questionnaire made in Google forms was used for data collection. Independent t-tests, Pearson Correlation and Regression analysis were performed using SPSS v25. Results: Increased prevalence of anxiety and insomnia in non-medical students as compared to the medical students was observed. There was statistically significant strong correlation between anxiety and insomnia of the enrolled subjects (r=0.742, p<0.001). A linear regression equation was formulated. Increased prevalence of anxiety and insomnia in females was also determined. Conclusion: Non-medical students, compared to medical students, among which, females, compared to males, were more likely to suffer from anxiety and insomnia during lockdown.


2020 ◽  
Vol 11 ◽  
Author(s):  
Yaoxian Jiang ◽  
Guangyao Yang ◽  
Yuan Liang ◽  
Qin Shi ◽  
Boqi Cui ◽  
...  

PurposeA computer-aided system was used to semiautomatically measure Tönnis angle, Sharp angle, and center-edge (CE) angle using contours of the hip bones to establish an auxiliary measurement model for developmental screening or diagnosis of hip joint disorders.MethodsWe retrospectively analyzed bilateral hip x-rays for 124 patients (41 men and 83 women aged 20–70 years) who presented at the Affiliated Zhongshan Hospital of Dalian University in 2017 and 2018. All images were imported into a computer-aided detection system. After manually outlining hip bone contours, Tönnis angle, Sharp angle, and CE angle marker lines were automatically extracted, and the angles were measured and recorded. An imaging physician also manually measured all angles and recorded hip development, and Pearson correlation coefficients were used to compare computer-aided system measurements with imaging physician measurements. Accuracy for different angles was calculated, and the area under the receiver operating characteristic (AUROC) curve was used to represent the diagnostic efficiency of the computer-aided system.ResultsFor Tönnis angle, Sharp angle, and CE angle, correlation coefficients were 0.902, 0.887, and 0.902, respectively; the accuracies of the computer-aided detection system were 89.1, 93.1, and 82.3%; and the AUROC curve values were 0.940, 0.956, and 0.948.ConclusionThe measurements of Tönnis angle, Sharp angle, and CE angle using the semiautomatic system were highly correlated with the measurements of the imaging physician and can be used to assess hip joint development with high accuracy and diagnostic efficiency.


1975 ◽  
Vol 19 ◽  
pp. 1-17 ◽  
Author(s):  
Ronald Jenkins

X-ray spectrometry is an old technique dating back some sixty-odd years and although most of the early interest revolved around the qualitative aspects of the method it wasn't long before attempts were made to obtain quantitative data. One of the first recorded attempts was that by Coster and von Hevesey who in 1923 accurately determined the amount of hafnium in zirconium using tantalum as an internal standard. Glocker and Schreiber were the first to attempt calculation of X-ray characteristic line intensity from first principles although no attempt was made at that time to correct for secondary fluorescence. In von Hevesey's book, “Chemical Analysis by X-Rays,” published in 1932 , a whole chapter is devoted to what is called “Disturbing effects and their avoidance.” Among the effects discussed were primary and secondary absorbtion and third element effects. Matrix correction equations were developed although most of the quantitative work at that time was done using internal standards.


2020 ◽  
Vol 9 (4) ◽  
pp. 335-344
Author(s):  
Marcus P.J. van Diemen ◽  
Ellen P. Hart ◽  
Pieter W. Hameeteman ◽  
Emma M. Coppen ◽  
Jessica Y. Winder ◽  
...  

Background: Huntington’s disease (HD) is a neurodegenerative disease with cognitive, motor and psychiatric symptoms. A toxic accumulation of misfolded mutant huntingtin protein (Htt) induces mitochondrial dysfunction, leading to a bioenergetic insufficiency in neuronal and muscle cells. Improving mitochondrial function has been proposed as an opportunity to treat HD, but it is not known how mitochondrial function in different tissues relates. Objective: We explored associations between central and peripheral mitochondrial function in a group of mild to moderate staged HD patients. Methods: We used phosphorous magnetic resonance spectroscopy (31P-MRS) to measure mitochondrial function in vivo in the calf muscle (peripheral) and the bio-energetic state in the visual cortex (central). Mitochondrial function was also assessed ex vivo in circulating peripheral blood mononuclear cells (PBMCs). Clinical function was determined by the Unified Huntington’s Disease Rating Scale (UHDRS) total motor score. Pearson correlation coefficients were computed to assess the correlation between the different variables. Results: We included 23 manifest HD patients for analysis. There was no significant correlation between central bio-energetics and peripheral mitochondrial function. Central mitochondrial function at rest correlated significantly to the UHDRS total motor score (R = –0.45 and –0.48), which increased in a subgroup with the largest number of CAG repeats. Discussion: We did not observe a correlation between peripheral and central mitochondrial function. Central, but not peripheral, mitochondrial function correlated to clinical function. Muscle mitochondrial function is a promising biomarker to evaluate disease-modifying compounds that improve mitochondrial function, but Huntington researchers should use central mitochondrial function to demonstrate proof-of-pharmacology of disease-modifying compounds.


2020 ◽  
Vol 24 (5) ◽  
pp. 457-460
Author(s):  
Lauren A.V. Orenstein ◽  
Adaugo Amah ◽  
Fiona M. Shaw ◽  
Chao Zhang ◽  
Robert A. Swerlick ◽  
...  

Background Hidradenitis suppurativa (HS) is a chronic inflammatory skin disease that severely impairs patients’ quality of life (QoL). Instruments such as the 10-item Dermatology Life Quality Index and 16-item Skindex-16 have been used to assess QoL in HS; however, it is unknown whether the shorter 3-item Skindex-mini can also provide an accurate assessment of skin-related QoL in patients with HS. Objectives The aim was to assess how well the Skindex-16 correlates with its shorter adaptation, the Skindex-mini, in capturing QoL among patients with HS. Methods This retrospective cross-sectional study included all HS patients seen in the HS Clinic at The Emory Clinic between January 1, 2019, and August 16, 2019. We compared the correlation between the symptom, emotion, and function domains of the Skindex-16 and Skindex-mini using Pearson correlation coefficients (CC). Secondary outcome measures included individual survey item analysis, ItchyQuant scores, and numeric rating scale of pain. Results We identified 108 encounters among 75 unique hidradenitis suppurativa patients (43 black/African American, 18 white, 5 Asian/Pacific Islander, 3 Latino, 4 Other, 2 unknown). Pearson CC between the Skindex-16 and Skindex-mini domain scores for all encounters were 0.770 ( P < .001), 0.787 ( P < .001), and 0.801 ( P < .001) for the symptom, emotion, and function domains, respectively. The mean pain and ItchyQuant scores were 4.14 (SD 3.31) and 3.55 (SD 3.34), respectively. Conclusions The Skindex-mini correlated highly with the Skindex-16 in a racially diverse group of patients with HS. The Skindex-mini is a streamlined QoL instrument that could be practically implemented into routine clinical care among diverse patients presenting to dermatology.


Sign in / Sign up

Export Citation Format

Share Document