scholarly journals Composite vs Ceramic Computer-aided Design/Computer-assisted Manufacturing Crowns in Endodontically Treated Teeth: Analysis of Marginal Adaptation

2013 ◽  
Vol 38 (6) ◽  
pp. 663-673 ◽  
Author(s):  
A Ramírez-Sebastià ◽  
T Bortolotto ◽  
M Roig ◽  
I Krejci

SUMMARY Objectives To compare the marginal adaptation between ceramic and composite CEREC crowns in endodontically treated teeth restored with endocrowns or with a short or a long post. Methodology Forty-eight intact maxillary incisors were used. After endodontic treatment, the crowns were sectioned 2 mm coronally to the cemento-enamel junction, which provided a ferrule of 2 mm. The prepared teeth were divided randomly into six groups (n=8). Group 1 was restored with a large fiberglass post, composite core, and ceramic full-coverage computer-aided design/computer-assisted manufacturing (CAD-CAM) crown. Group 2 was restored with a short fiberglass post, composite core, and ceramic full-coverage CAD-CAM crown. Group 3 was restored with a large fiberglass post, composite core, and composite full-coverage CAD-CAM crown (LPCpr). Group 4 was restored with a short fiberglass post, composite core, and composite full-coverage CAD-CAM crown (SPCpr). Groups 5 and 6 were restored with ceramic and composite CEREC machined endocrowns, respectively (EndoCer and EndoCpr). The restored teeth were loaded thermomechanically in a computer-controlled chewing machine. Impressions of each restoration were made in a polyvinylsiloxane material before and after loading. Gold-coated epoxy replicas were prepared for scanning electron microscopy examination at 200× magnification. Results Loading had a statistically significant effect (p<0.05) on the percentage of “continuous margin” in all groups. The LPCpr, SPCpr, and EndoCpr groups showed the highest percentage of continuous margin initially and after loading. The effect of the different post lengths on marginal adaptation was not significant (p>0.05). Conclusion CAD-CAM crowns fabricated from millable composite resin blocks (Paradigm MZ100) offer a superior option to all-ceramic crowns (IPS Empress CAD).

Biology ◽  
2021 ◽  
Vol 10 (11) ◽  
pp. 1170
Author(s):  
Giulio Marchesi ◽  
Alvise Camurri Piloni ◽  
Vanessa Nicolin ◽  
Gianluca Turco ◽  
Roberto Di Lenarda

Restorative materials are experiencing an extensive upgrade thanks to the use of chairside Computer-aided design/computer-assisted manufacturing (CAD/CAM) restorations. Therefore, due to the variety offered in the market, choosing the best material could be puzzling for the practitioner. The clinical outcome of the restoration is influenced mainly by the material and its handling than by the fabrication process (i.e., CAD/CAM). Information on the restorative materials performances can be difficult to gather and compare. The aim of this article is to provide an overview of chairside CAD/CAM materials, their classification, and clinically relevant aspects that enable the reader to select the most appropriate material for predictable success.


2014 ◽  
Vol 7 (2) ◽  
pp. 158-166 ◽  
Author(s):  
Frank Wilde ◽  
Carl-Peter Cornelius ◽  
Alexander Schramm

We investigated the workflow of computer-assisted mandibular reconstruction that was performed with a patient-specific mandibular reconstruction plate fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) techniques and a fibula flap. We assessed the feasibility of this technique from virtual planning to the completion of surgery. Computed tomography (CT) scans of a cadaveric skull and fibula were obtained for the virtual simulation of mandibular resection and reconstruction using ProPlan CMF software (Materialise®/DePuy Synthes®). The virtual model of the reconstructed mandible provided the basis for the computer-aided design of a patient-specific reconstruction plate that was milled from titanium using a five-axis milling machine and CAM techniques. CAD/CAM techniques were used for producing resection guides for mandibular resection and cutting guides for harvesting a fibula flap. Mandibular reconstruction was simulated in a cadaveric wet laboratory. No problems were encountered during the procedure. The plate was fixed accurately to the residual bone without difficulty. The fibula segments were attached to the plate rapidly and reliably. The fusion of preoperative and postoperative CT datasets demonstrated high reconstruction precision. Computer-assisted mandibular reconstruction with CAD/CAM-fabricated patient-specific reconstruction plates appears to be a promising approach for mandibular reconstruction. Clinical trials are required to determine whether these promising results can be translated into successful practice and what further developments are needed.


1983 ◽  
Vol 27 (5) ◽  
pp. 391-391
Author(s):  
H. McIlvaine Parsons

Although automation in manufacturing is by no means novel, only recently have such manifestations as increasing use of robots and CAD/CAM (Computer-Aided Design/Computer-Assisted Manufacturing) involved human factors scientists/practitioners. This panel session suggests how these can contribute to industrial productivity by examining and recommending suitable divisions of labor between automation and workers and ways to improve interactions between them. For the most part these considerations have been sadly lacking in both technical and popular discussions about industrial robots. Five panelist will approach them from two perspectives: actual human factors experience in industrial automation, including robotics, and applicable experience in closely related areas, such as the use of teleoperators in hostile environments (nuclear and battlefield).


2016 ◽  
Vol 41 (6) ◽  
pp. 607-616 ◽  
Author(s):  
MD Gaintantzopoulou ◽  
HM El-Damanhoury

SUMMARY The aim of the study was to evaluate the effect of preparation depth and intraradicular extension on the marginal and internal adaptation of computer-aided design/computer-assisted manufacture (CAD/CAM) endocrown restorations. Standardized preparations were made in resin endodontic tooth models (Nissin Dental), with an intracoronal preparation depth of 2 mm (group H2), with extra 1- (group H3) or 2-mm (group H4) intraradicular extensions in the root canals (n=12). Vita Enamic polymer-infiltrated ceramic-network material endocrowns were fabricated using the CEREC AC CAD/CAM system and were seated on the prepared teeth. Specimens were evaluated by microtomography. Horizontal and vertical tomographic sections were recorded and reconstructed by using the CTSkan software (TView v1.1, Skyscan).The surface/void volume (S/V) in the region of interest was calculated. Marginal gap (MG), absolute marginal discrepancy (MD), and internal marginal gap were measured at various measuring locations and calculated in microscale (μm). Marginal and internal discrepancy data (μm) were analyzed with nonparametric Kruskal-Wallis analysis of variance by ranks with Dunn's post hoc, whereas S/V data were analyzed by one-way analysis of variance and Bonferroni multiple comparisons (α=0.05). Significant differences were found in MG, MD, and internal gap width values between the groups, with H2 showing the lowest values from all groups. S/V calculations presented significant differences between H2 and the other two groups (H3 and H4) tested, with H2 again showing the lowest values. Increasing the intraradicular extension of endocrown restorations increased the marginal and internal gap of endocrown restorations.


2016 ◽  
Vol 31 (3) ◽  
pp. 140 ◽  
Author(s):  
Adriana Postiglione Buhrer Samra ◽  
Eduardo Morais ◽  
Rui Fernando Mazur ◽  
Sergio Roberto Vieira ◽  
Rodrigo Nunes Rached

Objective: The CAD/CAM process in Dentistry describes an indirect restoration designed by a computer (Computer Aided Design) and milled by a computer assisted machine (Computer Aided Machined). It can be divided into three different steps: data acquisition, indirect restoration design and construction of the prosthesis itself. This paper relates the state of art of the CAD/CAM systems in dentistry and some of the concerns and special cares that can interphere to optimize their results. Yet, it stablish some considerations about the role of CAD/CAM systems in the present and near future of the dental practice.Methods: The Scientific Electronic Library Online (SCIELO) and biomedical journal literature of the National Library of Medicine (MEDLINE/PubMed) electronic databases were used to search the literature from 2004 to 2013.Conclusion: There are advantages to using CAD/CAM in Dentistry: the new materials are esthetically pleasing and durable; there is increased efficiency in laboratory processing; quick fabrication of the restoration; and quality control of restorations such as fit, mechanical durability and predictability. These advantages will ultimately benefit our patients.


2020 ◽  
Vol 19 ◽  
pp. e200537
Author(s):  
Roniel Kapler ◽  
Michelle Villa Oliveira ◽  
Ingrid de Oliveira Bandeira ◽  
Thayara Coelho Metzker ◽  
Adriana Oliveira Carvalho ◽  
...  

Aim: The aim of this study was to evaluate the marginal adaptation of ceramic and composite resin crowns fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) technology using an intraoral digital scanner. Methods: A human mandibular right second molar was prepared for a ceramic crown. The impressions were made using intraoral scanning device and crowns were milled. Tem crowns were fabricated for each group (n=10): GF – Feldspathic Ceramic (Cerec Blocs, Sirona), GL - Lithium Disilicate Ceramic (IPS e.max CAD, Ivoclar), GG - composite resin (Grandio Blocs, VOCO) and GB - composite resin (Brava Block, FGM). The marginal gap was measured for each specimen at 4 points under magnification with a stereomicroscope. All data were statistically analyzed using one-way ANOVA followed by the Tukey’s test (α=.05). Results: The lowest marginal discrepancy value was observed in GB (60.95 ± 13.64 μm), which was statistically different from the GL (84.22 ± 20.86 μm). However, there was no statistically significant difference between these groups when compared with the other groups, GF (73.26 ±8.19 μm) and GG (68.42 ± 11.31 μm). Conclusion: It can be concluded that the composite resin presented the lowest variance compared to the lithium disilicate glass ceramic, although the marginal gap of all materials tested was within the acceptable clinical limit (120 μm).


Author(s):  
A. N. Bozhko

Computer-aided design of assembly processes (Computer aided assembly planning, CAAP) of complex products is an important and urgent problem of state-of-the-art information technologies. Intensive research on CAAP has been underway since the 1980s. Meanwhile, specialized design systems were created to provide synthesis of assembly plans and product decompositions into assembly units. Such systems as ASPE, RAPID, XAP / 1, FLAPS, Archimedes, PRELEIDES, HAP, etc. can be given, as an example. These experimental developments did not get widespread use in industry, since they are based on the models of products with limited adequacy and require an expert’s active involvement in preparing initial information. The design tools for the state-of-the-art full-featured CAD/CAM systems (Siemens NX, Dassault CATIA and PTC Creo Elements / Pro), which are designed to provide CAAP, mainly take into account the geometric constraints that the design imposes on design solutions. These systems often synthesize technologically incorrect assembly sequences in which known technological heuristics are violated, for example orderliness in accuracy, consistency with the system of dimension chains, etc.An AssemBL software application package has been developed for a structured analysis of products and a synthesis of assembly plans and decompositions. The AssemBL uses a hyper-graph model of a product that correctly describes coherent and sequential assembly operations and processes. In terms of the hyper-graph model, an assembly operation is described as shrinkage of edge, an assembly plan is a sequence of shrinkages that converts a hyper-graph into the point, and a decomposition of product into assembly units is a hyper-graph partition into sub-graphs.The AssemBL solves the problem of minimizing the number of direct checks for geometric solvability when assembling complex products. This task is posed as a plus-sum two-person game of bicoloured brushing of an ordered set. In the paradigm of this model, the brushing operation is to check a certain structured fragment for solvability by collision detection methods. A rational brushing strategy minimizes the number of such checks.The package is integrated into the Siemens NX 10.0 computer-aided design system. This solution allowed us to combine specialized AssemBL tools with a developed toolkit of one of the most powerful and popular integrated CAD/CAM /CAE systems.


Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 959
Author(s):  
Verónica Rodríguez ◽  
Celia Tobar ◽  
Carlos López-Suárez ◽  
Jesús Peláez ◽  
María J. Suárez

The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.


Sign in / Sign up

Export Citation Format

Share Document