Cervical Margin Integrity of Class II Resin Composite Restorations in Laser- and Bur-Prepared Cavities Using Three Different Adhesive Systems

2012 ◽  
Vol 37 (3) ◽  
pp. 316-323 ◽  
Author(s):  
PA Oskoee ◽  
S Kimyai ◽  
ME Ebrahimi ◽  
S Rikhtegaran ◽  
F Pournaghi-Azar

SUMMARY One of the challenges in durability of posterior tooth-colored restorative materials is polymerization shrinkage, which results in gap formation between the restoration and tooth structure. The aim of the present study was to investigate marginal adaptation of Class II composite restorations using a self-etching and two etch-and-rinse adhesive systems in cavities prepared either with bur or Er,Cr:YSGG laser. A total of 45 extracted sound human premolars were selected. In each tooth, mesial and distal Class II cavities were prepared either by a diamond bur or by Er,Cr:YSGG laser with the margins 1 mm apical to the cemento-enamel junction. Then the teeth were randomly divided into three groups of 15 each, according to the type of the adhesive system used (Single Bond, Single Bond 2, and Adper Easy One adhesive systems). Subsequent to restoring the teeth, the specimens were subjected to thermal cycling between 5 ± 2°C and 55 ± 2°C for 500 cycles and were then cut longitudinally into two halves using a diamond disk. Marginal adaptation was evaluated using a stereomicroscope, and the values for gap widths were obtained in micrometers. Data were analyzed using two-factor analysis of variance and post hoc tests. There were statistically significant differences in mean marginal gap widths between the adhesive type and preparation groups (p<0.05). The interfacial gap width in bur-prepared cavities was significantly less than that in laser-prepared cavities, and the lowest gap width was observed in Adper Easy One regardless of the type of the preparation.

2014 ◽  
Vol 38 (3) ◽  
pp. 223-228 ◽  
Author(s):  
H C Güngör ◽  
E Canoğlu ◽  
Z C Çehreli

>Purpose: To compare the occlusal and gingival microleakage of Class-II composite restorations utilizing etch-and-rinse and self-etch adhesives and different liner materials in primary and permanent teeth. Study design: Standardized class-II cavities were prepared in freshly-extracted sound primary and permanent molars (n=80/each), with all cavosurface margins involving enamel. The main experimental groups were; A. Single Bond 2/primary teeth; B. Adper SE Plus/primary teeth; C. Single Bond 2/permanent teeth; and D. Adper SE Plus/permanent teeth. Each group comprised 4 subgroups (n=10/each) with respect to the liner material employed (n=10/subgroup): 1. Fuji VII; 2. Fuji Triage; 3. Filtek Supreme XT Flowable Composite, and 4. No liner. All teeth were restored with Filtek Supreme XT Universal Nanofilled Composite. Following thermocycling and immersion in basic fuchsin, the extent of microleakage was measured on crown sections using image analysis. The data were analyzed with Wilcoxon Signed Ranks Test, Mann-Whitney U-Test and Kruskal-Wallis One-Way ANOVA at ?=0.05. Results: In both primary and permanent teeth the use of etch-and-rinse adhesive resulted in similar occlusal and gingival microleakage values (p>0.05). As for the self-etch adhesive, similar results were observed (p>0.05) with the exception of significantly less occlusal leakage in the Fuji Triage VII and Fuji Triage subgroups of primary teeth than those of permanent teeth (pÃ0.05). When the effects of liner material and the type of adhesive were disregarded, significantly more gingival microleakage was observed in primary teeth than in permanent teeth (pÃ0.01), while the occlusal microleakage values were similar (p>0.05). Irrespective of the tooth type and adhesive material, comparison of subgroups containing a liner material with those without one revealed no significant differences for both occlusal and gingival microleakage values (p>0.05). Conclusions: Occlusal microleakage was similar in both primary and permanent teeth, while a lesser extent of gingival seal was observed in primary teeth. Overall, placement of a liner material did not improve resistance to microleakage.


2017 ◽  
Vol 16 ◽  
pp. 1-11
Author(s):  
Shahin Kasraei ◽  
Ebrahim Yarmohammadi ◽  
Maryam Farhadian ◽  
Mona Malek

Objective: this study aimed to assess the effect of treatment of phosphoric acid etched dentin surface with 5% bromelain enzyme and Nd:YAG laser prior to the use of etch and rinse adhesive systems on microleakage margins of class V composite restorations. Materials and Methods: sixty sound premolar teeth were selected. Standard class V cavities were prepared in the buccal and lingual surfaces of each teeth. Preparation in that way 1 mm of the cavity was above and 1 mm of it was below the cementoenamel junction. The teeth were then randomly divided into three groups including 20 teeth(40cavities  in each gorup). Two ethanol base etch and rinse system (Adper Single Bond and OptiBond Solo) was applied in each group. In the control group, cavities were etched with 37% phosphoric acid. Adper Single Bond was applied to 20 and OptiBond Solo was applied to the remaining 20 cavities and they were restored with Z250 composite (n=40). The same procedures were performed in bromelain and Nd:YAG laser groups with the difference that prior to the application of adhesive, aqueous 5% bromelain was applied in bromelain group while Nd:YAG laser was irradiated in laser group. All teeth were thermocycled and their apices were sealed with sticky wax. The tooth surfaces were coated with nail varnish except for 1 mm around the restoration margins, and the teeth were then immersed in fuchsine and sectioned by a diamond disc into mesial and distal halves. Marginal microleakage at both sides was determined and scored under a stereomicroscope at x40 magnification. Then data were analyzed using the Kruskal Wallis and Mann Whitney tests (α=0.05). Results: according the result of Mann Whitney test, Cervical margins showed significantly higher microleakage than the occlusal margins (P=0.000) but no significant difference was noted in microleakage of occlusal (P=0.362) or gingival (P=0.147) margins among the three groups by Kruskal Wallis test. Conclusion: in conclusion, application of proteolytic agents(5% bromelain solution and Nd:YAG laser)  on acid-etched dentin surface prior to the application of adhesive has no significant effect on marginal microleakage of class V composite restorations. 


2020 ◽  
Vol 45 (5) ◽  
pp. 473-483 ◽  
Author(s):  
CAGA Costa ◽  
NLG Albuquerque ◽  
JS Mendonça ◽  
AD Loguercio ◽  
VPA Saboia ◽  
...  

Clinical Relevance At 24 months, the dentin pretreatment with epigallocatechin-3-gallate did not impair the clinical performance of the adhesive Single Bond Universal regardless of the bonding strategy used. SUMMARY Purpose: To evaluate the two-year effect of dentin pretreatment with epigallocatechin-3-gallate (EGCG) on the clinical performance of restorations of noncarious cervical lesions (NCCLs) with Single Bond Universal, applied in two different modes (self-etch and etch-and-rinse). Methods and Materials: In this randomized clinical trial, 33 volunteers were selected, and 156 NCCLs were assigned to four groups: ER, etch-and-rinse; ER-EGCG, 0.1% EGCG dentin pretreatment + etch-and-rinse; SE, self-etch; and SE-EGCG, 0.1% EGCG dentin pretreatment + self-etch. The NCCLs were restored with a nanofilled resin composite and evaluated at baseline and at six, 12, 18, and 24 months using FDI criteria for retention, marginal staining, marginal adaptation, caries, and postoperative sensitivity. Two evaluators were blinded to the treatments performed, and impressions were taken for resin replicas to allow indirect observations. Statistical analyses were performed with Kruskal-Wallis and McNemar tests with a significance level of 5%. Results: Six restorations (one from ER, two from SE, one from ER-EGCG, and two from SEEGCG) were lost at 24 months with no significant differences (p>0.05). The retention rates were 97.0% (ER and ER-EGCG), 94.1% (SE), and 94.2% (SE-EGCG). For marginal adaptation, a significant difference was detected between the baseline and 24 months for the SE group (p=0.0313). There were no statistical differences among all other evaluated criteria at 24 months, neither for each group at baseline nor for 24-month comparisons (p>0.05). Conclusions: The pretreatment with EGCG provided no benefit in the clinical performance of the adhesive regardless of the bonding strategy used. In addition, it adds an additional required step to the restorative procedure.


2021 ◽  
Author(s):  
TP Matos ◽  
TA Hanzen ◽  
R Almeida ◽  
C Tardem ◽  
MC Bandeca ◽  
...  

SUMMARY Objectives: To evaluate the 5-year clinical performance of two-step etch-and-rinse adhesives in noncarious cervical lesions (NCCL). Methods and Materials: The sample comprised 35 adults with at least two similar-sized NCCL. Seventy restorations were placed, according to one of the following groups: Adper Single Bond 2 (SB) and Ambar (AM). The restorations were placed incrementally using a resin composite (Opallis). The restorations were evaluated at baseline and after 6 and 18 months and 5 years using some items of the FDI criteria. The differences in the ratings of the two materials after 6 months, 18 months, and 5 years were performed with Friedman repeated measures ANOVA by rank and McNemar test for significance in each pair (α=0.05). Results: Five patients did not attend the 60-month recall. No significant differences were observed between the materials for any criteria evaluated. Twenty-one restorations failed (12 for SB and 9 for AM) after 60 months. Thus, the retention rate for SB at 60 months were 55.6% for SB and 71% for AM (p=0.32). After 60 months, 12 restorations (6 for SB and 6 AM) showed some loss of marginal adaptation (p=1.0). Slight marginal discoloration was observed in 10 restorations (6 for SB and 4 AM; p=0.91). Five restorations (2 for SB and 3 for AM) showed recurrences of caries (p=1.0). Conclusions: Both two-step etch-and-rinse adhesives—Adper Single Bond 2, a polyalkenoic acid-containing adhesive, and Ambar, a 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing adhesive—showed acceptable clinical performance after 60 months.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Secil Bektaş Donmez ◽  
Melek D. Turgut ◽  
Serdar Uysal ◽  
Pinar Ozdemir ◽  
Meryem Tekcicek ◽  
...  

The purpose of this study was to assess the clinical performance of composite restorations placed with different adhesive systems in primary teeth. In 32 patients, 128 composite restorations were placed using a split-mouth design as follows (4 groups/patient): three-step etch-and-rinse (Group 1), two-step etch-and-rinse (Group 2), two-step self-etch (Group 3), and one-step self-etch (Group 4). The restorations were clinically evaluated at baseline and at 6, 18, and 36 months according to the FDI criteria. There was no significant difference between the adhesive systems in retention of the restorations (p>0.05). Over time, there was a statistically significant decrease in marginal adaptation in all groups, whereas surface and marginal staining significantly increased in Groups 3 and 4 (p<0.05). The etch-and-rinse adhesive systems resulted in better marginal adaptation than the self-etch adhesive systems (p<0.05). It was concluded that preetching of the primary enamel might help improve the clinical performance of the self-etch adhesive systems in primary teeth.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


Folia Medica ◽  
2016 ◽  
Vol 57 (3-4) ◽  
pp. 250-256 ◽  
Author(s):  
Neshka A. Manchorova-Veleva ◽  
Stoyan B. Vladimirov ◽  
Donka А. Keskinova

Abstract BACKGROUND: Dental adhesives are believed to influence marginal adaptation and marginal discoloration when used under posterior resin-based composite restorations. Studies on the latest adhesive systems reveal that the group of the three-step etch-and-rinse adhesive (3-E&RA) and the one-step self-etch adhesive (1-SEA) have entirely different bonding mechanisms, as well as different bond strength and resistance to chemical, thermal and mechanical factors. STUDY OBJECTIVES: A hypothesis that a 1-SEA would result in greater enamel marginal discoloration and poorer marginal adaptation than a 3-E&RA was tested. MATERIAL AND METHODS: One hundred restorations were placed with a 1-SEA and 100 restorations with a 3-E&RA. Teeth were restored with Filtek Supreme nanofilled resin-composite and were evaluated for marginal adaptation and marginal discoloration at baseline, and 6 months, 12 months, and 36 months postoperatively. RESULTS: The statistical analysis revealed significant differences in marginal integrity between test groups. The 1-SEA resulted in greater enamel marginal discoloration and poorer marginal adaptation than the 3-E&RA at any recall time. CONCLUSIONS: Marginal adaptation and marginal discoloration depend on the type of dentin adhesive used. The restorations with Filtek Supreme and Scotchbond MP are better than the restorations with Adper Prompt L-Pop with regard to the marginal adaptation and marginal discoloration at 6-, 12- and 36-month evaluations.


2016 ◽  
Vol 41 (3) ◽  
pp. E57-E63 ◽  
Author(s):  
JD Theobaldo ◽  
A Catelan ◽  
U Rodrigues-Filho ◽  
GM Marchi ◽  
DANL Lima ◽  
...  

SUMMARY Objective: To evaluate the microshear bond strength of composite resin restorations in dental blocks with or without exposure to cigarette smoke. Method: Eighty bovine dental blocks were divided into eight groups (n=10) according to the type of adhesive (Scotchbond Multi-Purpose, 3M ESPE, St Paul, MN, USA [SBMP]; Single Bond 2, 3M ESPE [SB]; Clearfil SE Bond, Kuraray Medical Inc, Okayama, Japan [CSEB]; Single Bond Universal, 3M ESPE [SBU]) and exposure to smoke (no exposure; exposure for five days/20 cigarettes per day). The adhesive systems were applied to the tooth structure, and the blocks received a composite restoration made using a matrix of perforated pasta. Data were statistically analyzed using analysis of variance and Tukey test (α&lt;0.05). Results: For enamel, there was no difference between the presence or absence of cigarette smoke (p=0.1397); however, there were differences among the adhesive systems (p&lt;0.001). CSEB showed higher values and did not differ from SBU, but both were statistically different from SB. The SBMP showed intermediate values, while SB demonstrated lower values. For dentin, specimens subjected to cigarette smoke presented bond strength values that were lower when compared with those not exposed to smoke (p&lt;0.001). For the groups without exposure to cigarette smoke, CSEB showed higher values, differing from SBMP. SB and SBU showed intermediary values. For the groups with exposure to cigarette smoke, SBU showed values that were higher and statistically different from SB and CSEB, which presented lower values of bond strength. SBMP demonstrated an intermediate value of bond strength. Conclusion: The exposure of dentin to cigarette smoke influenced the bonding strength of adhesives, but no differences were noted in enamel.


Sign in / Sign up

Export Citation Format

Share Document