Effect of Light Energy Density on Conversion Degree and Hardness of Dual-cured Resin Cement

2010 ◽  
Vol 35 (1) ◽  
pp. 120-124 ◽  
Author(s):  
P. C. P. Komori ◽  
A. B. Paula ◽  
A. A. Martin ◽  
R. N. Tango ◽  
M. A. C. Sinhoreti ◽  
...  

Clinical Relevance Light energy density can influence the curing of dual-cured resin cement. The ultimate physical properties of dual-cured resin cement depend on light energy delivered from the light-curing unit. It can guide the clinicians to select the appropriate curing unit for curing dual cement.

2020 ◽  
Author(s):  
RQ Ramos ◽  
RR Moraes ◽  
GC Lopes

Clinical Relevance The use of multipeak LED light-curing guarantees efficiency on light activation of Ivocerin-containing light-cured resin cement.


2007 ◽  
Vol 16 (6) ◽  
pp. 480-484 ◽  
Author(s):  
Rubens Nisie Tango ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Américo Bortolazzo Correr ◽  
Lourenço Correr-Sobrinho ◽  
Guilherme Elias Peçanha Henriques

2009 ◽  
Vol 20 (5) ◽  
pp. 410-413 ◽  
Author(s):  
Rogério Vieira Reges ◽  
Ana Rosa Costa ◽  
Américo Bortolazzo Correr ◽  
Evandro Piva ◽  
Regina Maria Puppin-Rontani ◽  
...  

The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the catalyst paste and inserted into a black Teflon mold (5 mm diameter x 1 mm high). A transparent strip was placed over the mold and a ceramic disc (Duceram Plus, shade A3) was positioned over the resin cement. Light-activation was performed through the ceramic for 40 s using quartz-tungsten-halogen (QTH) (XL 2500; 3M ESPE) or light-emitting diode (LED) (Ultrablue Is, DMC) LCUs with power density of 615 and 610 mW/cm2, respectively. The Koop hardness was measured using a microhardness tester HMV 2 (Shimadzu) after 15 min or 24 h. Four indentations were made in each specimen. Data were subjected to ANOVA and Tukey's test (a=0.05). The QTH LCU provided significantly higher (p<0.05) KHN values than the LED LCU. When the post-cure times were compared for the same shade, QTH and LED at 24 h provided significantly higher (p<0.05) KHN values than at 15 min. It may be concluded that the Knoop hardness was generally dependent on the LCU and post-cure time. The opaque shade of the resin cement showed lower Knoop hardness than the other shades for both LCUs and post-cure times.


2009 ◽  
Vol 23 (2) ◽  
pp. 108-112 ◽  
Author(s):  
Nelson Tetsu Iriyama ◽  
Rubens Nisie Tango ◽  
Izabella Paola Manetta ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Lourenço Correr Sobrinho ◽  
...  

2013 ◽  
Vol 8 (2) ◽  
pp. 141-146 ◽  
Author(s):  
Nurcan Ozakar Ilday ◽  
Yusuf Ziya Bayindir ◽  
Funda Bayindir ◽  
Aysel Gurpinar

2007 ◽  
Vol 32 (5) ◽  
pp. 443-450 ◽  
Author(s):  
M. G. Brackett ◽  
W. W. Brackett ◽  
W. D. Browning ◽  
F. A. Rueggeberg

Clinical Relevance The selection of light curing unit (quartz-tungsten-halogen or blue light-emitting diode), composite classification and shade have an influence on the amount of residual yellow after photocuring and, in some combinations, the color difference may be visually detectable.


2007 ◽  
Vol 32 (6) ◽  
pp. 571-578 ◽  
Author(s):  
K. M. Rode ◽  
Y. Kawano ◽  
M. L. Turbino

Clinical Relevance Different light curing units, the thickness of the resin composite increments and the exposure distance to a curing light may change the physical properties of a restorative material and compromise its mechanical behavior under clinical loading conditions. Understanding how these factors can affect the quality of restorative products may help the dental professional in selecting the best activating source for a specific clinical application.


10.2341/05-26 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 261-265 ◽  
Author(s):  
A. R. Yazici ◽  
A. Müftü ◽  
G. Kugel ◽  
R. D. Perry

Clinical Relevance The thickness of the residual dentin is a critical factor in the reducing thermal transfer to pulp, and this transfer varies with the curing unit used.


Sign in / Sign up

Export Citation Format

Share Document