954-P: Continuous Glucose Monitoring in Hospitalized Patients: A Systematic Meta-analysis and Review

Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 954-P
Author(s):  
NASSEH HASHEMI ◽  
KIM HOULIND ◽  
NIELS EJSKJAER
Diabetes ◽  
2020 ◽  
Vol 69 (Supplement 1) ◽  
pp. 849-P ◽  
Author(s):  
ALEXANDRA MIGDAL ◽  
ELIAS SPANAKIS ◽  
RODOLFO J. GALINDO ◽  
GEORGIA DAVIS ◽  
LAKSHMI G. SINGH ◽  
...  

2012 ◽  
Vol 166 (4) ◽  
pp. 567-574 ◽  
Author(s):  
A Szypowska ◽  
A Ramotowska ◽  
K Dżygało ◽  
D Golicki

ObjectiveReal-time continuous glucose monitoring (RT-CGM) provides detailed information on glucose patterns and trends, thus allowing the patients to manage their diabetes more effectively.DesignThe aim of this study was to explore the potential beneficial effects of the use of RT-CGM on diabetes management compared with self blood glucose measurement (SBGM) in patients with type 1 diabetes mellitus (T1DM), by means of a systematic review and meta-analysis of randomized controlled trials (RCTs).MethodsMEDLINE, EMBASE, and the Cochrane Library were searched through by two independent investigators for RCTs concerning the use of RT-CGM in patients with T1DM. Only studies with a similar insulin regimen in the experimental and control groups were included in the analysis.ResultsSeven RCTs (n=948) met the inclusion criteria. Combined data from all studies showed better HbA1c reduction in subjects using RT-CGM compared with those using SBGM (mean difference (MD) −0.25; 95% confidence interval (95% CI): from −0.34 to −0.17; P<0.001). Patients treated with insulin pump and RT-CGM had a lower HbA1c level compared with subjects managed with insulin pump and SBGM (four RCTs, n=497; MD −0.26; 95% CI: from −0.43 to −0.10; P=0.002). The benefits of applying RT-CGM were not associated with an increasing rate of major hypoglycemic episodes. The use of RT-CGM for over 60–70% of time was associated with a significant lowering of HbA1c.ConclusionsRT-CGM is more beneficial than SBGM in reducing HbA1c in patients with type 1 diabetes. Further studies are needed to evaluate the efficacy of this system in the pediatric population, especially in very young children.


2021 ◽  
Author(s):  
Georgia M. Davis ◽  
Elias K. Spanakis ◽  
Alexandra L. Migdal ◽  
Lakshmi G. Singh ◽  
Bonnie Albury ◽  
...  

<b>Background: </b>Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient use of CGM has remained investigational with limited data on its accuracy in the hospital setting. <p><b>Methods: </b>To analyze the accuracy of Dexcom G6 CGM,<b> </b>we compared retrospective matched-pair CGM and capillary point-of-care (POC) glucose data from three inpatient CGM studies (two interventional and one observational) in general medicine and surgery patients with diabetes treated with insulin. Analysis of accuracy metrics included mean absolute relative difference (MARD), median absolute relative difference (ARD), and proportion of CGM values within ±15, 20 and 30% or ±15, 20 and 30 mg/dL of POC reference values for blood glucose >100 mg/dL or ≤100 mg/dL, respectively (?/15, /20, 0/30). Clinical reliability was assessed using Clarke error grid analyses.</p> <p><b>Results: </b>A total of 218 patients were included (96% with type 2 diabetes) with a mean age of 60.6 ± 12 years. The overall MARD (n=4,067 matched glucose pairs) was 12.8% and median ARD was 10.1% [IQR 4.6, 17.6]. The proportion of readings meeting ?/15, /20 and 0/30 criteria were 68.7, 81.7, and 93.8%. Clarke error grid analysis showed 98.7% of all values in zones A+B. MARD and median ARD were higher in hypoglycemia (<70mg/dL) and severe anemia (hemoglobin <7g/dL).</p> <p><b>Conclusion: </b>Our results indicate that CGM technology is a reliable tool for hospital use and may help improve glucose monitoring in non-critically ill hospitalized patients with diabetes. </p>