The effects of gap size and disturbance type on invasion of wet pine savanna by cogongrass, Imperata cylindrica (Poaceae)

2000 ◽  
Vol 87 (9) ◽  
pp. 1279-1286 ◽  
Author(s):  
Sharon E. King ◽  
James B. Grace
Molecules ◽  
2021 ◽  
Vol 26 (16) ◽  
pp. 4717
Author(s):  
Romeo Nago ◽  
Paul Nayim ◽  
Armelle Mbaveng ◽  
James Mpetga ◽  
Gabin Bitchagno ◽  
...  

The local botanical Imperata cylindrica in Cameroon was investigated for its antibacterial potency. The methanol extract afforded a total of seven compounds, including five hitherto unreported compounds comprising three flavonoids (1–3) and two C-15 isoprenoid analogues (4 and 5) together with known derivatives (6 and 7). The novelty of the flavonoids was related to the presence of both methyl and prenyl groups. The potential origin of the methyl in the flavonoids is discussed, as well as the chemophenetic significance of our findings. Isolation was performed over repeated silica gel and Sephadex LH-20 column chromatography and the structures were elucidated by (NMR and MS). The crude methanol extract and isolated compounds showed considerable antibacterial potency against a panel of multi-drug resistant (MDR) bacterial strains. The best MIC values were obtained with compound (2) against S. aureus ATCC 25923 (32 µg/mL) and MRSA1 (16 µg/mL).


Arthroplasty ◽  
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Goki Kamei ◽  
Shigeki Ishibashi ◽  
Koki Yoshioka ◽  
Satoru Sakurai ◽  
Hiroyuki Inoue ◽  
...  

Abstract Background In total knee arthroplasty (TKA) using the modified gap technique, the soft-tissue balance is measured after osteotomy of the distal femur and proximal tibia (conventional bone gap). However, after osteotomy, the flexion gap size during 90° knee flexion may be larger than that observed after implantation. The tension of the lateral compartment during 90° flexion may also be reduced after osteotomy of the distal femur. We manufactured a distal femoral trial component to reproduce the condition after implantation and prior to posterior condyle osteotomy. This study aimed to evaluate the effect of the trial component on the flexion gap. Methods This prospective study included 21 consecutive patients aged 78 years with medial osteoarthritis who underwent cruciate-retaining TKA between February 2017 and March 2018. The postoperative flexion gap size and inclination during 90° flexion were compared between cases with and without the trial component. Results The mean joint gap size with the trial component (13.4 ± 0.80 mm) was significantly smaller than that without the trial component (14.7 ± 0.84 mm). The mean gap inclination angle with the trial component (3.7° ± 0.62°) was significantly smaller than that without the trial component (5.5° ± 0.78°). Conclusions In the present study, the joint gap size and medial tension were significantly reduced after the trial component had been set. Accurate measurement of the soft-tissue balance is an important factor in the modified gap technique, and this method using a distal femoral trial component can offer better outcomes than those achieved with conventional methods.


2021 ◽  
Author(s):  
Kankan Swargiary ◽  
Romuald Jolivot ◽  
Waleed Soliman Mohammed

AbstractA polymer based horizontal single step waveguide for the sensing of alcohol is developed and analyzed. The waveguide is fabricated by 3-dimensional (3D) printing digital light processing (DLP) technology using monocure 3D rapid ultraviolet (UV) clear resin with a refractive index of n = 1.50. The fabricated waveguide is a one-piece tower shaped ridge structure. It is designed to achieve the maximum light confinement at the core by reducing the effective refractive index around the cladding region. With the surface roughness generated from the 3D printing DLP technology, various waveguides with different gap sizes are printed. Comparison is done for the different gap waveguides to achieve the minimum feature gap size utilizing the light re-coupling principle and polymer swelling effect. This effect occurs due to the polymer-alcohol interaction that results in the diffusion of alcohol molecules inside the core of the waveguide, thus changing the waveguide from the leaky type (without alcohol) to the guided type (with alcohol). Using this principle, the analysis of alcohol concentration performing as a larger increase in the transmitted light intensity can be measured. In this work, the sensitivity of the system is also compared and analyzed for different waveguide gap sizes with different concentrations of isopropanol alcohol (IPA). A waveguide gap size of 300 µm gives the highest increase in the transmitted optical power of 65% when tested with 10 µL (500 ppm) concentration of IPA. Compared with all other gaps, it also displays faster response time (t = 5 seconds) for the optical power to change right after depositing IPA in the chamber. The measured limit of detection (LOD) achieved for 300 µm is 0.366 µL. In addition, the fabricated waveguide gap of 300 µm successfully demonstrates the sensing limit of IPA concentration below 400 ppm which is considered as an exposure limit by “National Institute for Occupational Safety and Health”. All the mechanical mount and the alignments are done by 3D printing fused deposition method (FDM).


Sign in / Sign up

Export Citation Format

Share Document