Thermal Effects of Short Radio Waves on Migrating Birds

1995 ◽  
Vol 5 (3) ◽  
pp. 672-679 ◽  
Author(s):  
Shani Kleinhaus ◽  
Berry Pinshow ◽  
Ron Frumkin ◽  
Raphael Ruppin ◽  
Menachem Margaliot
2017 ◽  
Vol 41 (1) ◽  
pp. 108-115 ◽  
Author(s):  
Christian Hoyer ◽  
Christian Pfütze ◽  
Rudy Plarre ◽  
Ulf Trommler ◽  
Steffen Steinbach ◽  
...  

2019 ◽  
Vol 16 (161) ◽  
pp. 20190716 ◽  
Author(s):  
Dmitry Kobylkov ◽  
Joe Wynn ◽  
Michael Winklhofer ◽  
Raisa Chetverikova ◽  
Jingjing Xu ◽  
...  

According to the currently prevailing theory, the magnetic compass sense in night-migrating birds relies on a light-dependent radical-pair-based mechanism. It has been shown that radio waves at megahertz frequencies disrupt magnetic orientation in migratory birds, providing evidence for a quantum-mechanical origin of the magnetic compass. Still, many crucial properties, e.g. the lifetime of the proposed magnetically sensitive radical pair, remain unknown. The current study aims to estimate the spin coherence time of the radical pair, based on the behavioural responses of migratory birds to broadband electromagnetic fields covering the frequency band 0.1–100 kHz. A finding that the birds were unable to use their magnetic compass under these conditions would imply surprisingly long-lived (greater than 10 µs) spin coherence. However, we observed no effect of 0.1–100 kHz radiofrequency (RF) fields on the orientation of night-migratory Eurasian blackcaps ( Sylvia atricapilla ). This suggests that the lifetime of the spin coherence involved in magnetoreception is shorter than the period of the highest frequency RF fields used in this experiment (i.e. approx. 10 µs). This result, in combination with an earlier study showing that 20–450 kHz electromagnetic fields disrupt magnetic compass orientation, suggests that the spin coherence lifetime of the magnetically sensitive radical pair is in the range 2–10 µs.


2021 ◽  
Vol 87 (1) ◽  
Author(s):  
A. G. Mikhaylenko ◽  
V. S. Beskin ◽  
Ya. N. Istomin

Thermal effects on the properties of four electromagnetic waves propagating in the pulsar magnetosphere are analysed. It is shown that thermal effects change only quantitatively the dispersion properties of superluminal ordinary O-mode freely escaping the pulsar magnetosphere; whereas properties of the extraordinary X-mode remain unchanged. The research shows that for two subluminal waves propagating along magnetic field lines thermal effects result in essential absorption. However, this attenuation occurs at considerable distances from the neutron star, and there is no doubt of their existence.


1994 ◽  
Vol 144 ◽  
pp. 21-28 ◽  
Author(s):  
G. B. Gelfreikh

AbstractA review of methods of measuring magnetic fields in the solar corona using spectral-polarization observations at microwaves with high spatial resolution is presented. The methods are based on the theory of thermal bremsstrahlung, thermal cyclotron emission, propagation of radio waves in quasi-transverse magnetic field and Faraday rotation of the plane of polarization. The most explicit program of measurements of magnetic fields in the atmosphere of solar active regions has been carried out using radio observations performed on the large reflector radio telescope of the Russian Academy of Sciences — RATAN-600. This proved possible due to good wavelength coverage, multichannel spectrographs observations and high sensitivity to polarization of the instrument. Besides direct measurements of the strength of the magnetic fields in some cases the peculiar parameters of radio sources, such as very steep spectra and high brightness temperatures provide some information on a very complicated local structure of the coronal magnetic field. Of special interest are the results found from combined RATAN-600 and large antennas of aperture synthesis (VLA and WSRT), the latter giving more detailed information on twodimensional structure of radio sources. The bulk of the data obtained allows us to investigate themagnetospheresof the solar active regions as the space in the solar corona where the structures and physical processes are controlled both by the photospheric/underphotospheric currents and surrounding “quiet” corona.


Author(s):  
K.C. Newton

Thermal effects in lens regulator systems have become a major problem with the extension of electron microscope resolution capabilities below 5 Angstrom units. Larger columns with immersion lenses and increased accelerating potentials have made solutions more difficult by increasing the power being handled. Environmental control, component choice, and wiring design provide answers, however. Figure 1 indicates with broken lines where thermal problems develop in regulator systemsExtensive environmental control is required in the sampling and reference networks. In each case, stability better than I ppm/min. is required. Components with thermal coefficients satisfactory for these applications without environmental control are either not available or priced prohibitively.


Author(s):  
A. G. Jackson ◽  
M. Rowe

Diffraction intensities from intermetallic compounds are, in the kinematic approximation, proportional to the scattering amplitude from the element doing the scattering. More detailed calculations have shown that site symmetry and occupation by various atom species also affects the intensity in a diffracted beam. [1] Hence, by measuring the intensities of beams, or their ratios, the occupancy can be estimated. Measurement of the intensity values also allows structure calculations to be made to determine the spatial distribution of the potentials doing the scattering. Thermal effects are also present as a background contribution. Inelastic effects such as loss or absorption/excitation complicate the intensity behavior, and dynamical theory is required to estimate the intensity value.The dynamic range of currents in diffracted beams can be 104or 105:1. Hence, detection of such information requires a means for collecting the intensity over a signal-to-noise range beyond that obtainable with a single film plate, which has a S/N of about 103:1. Although such a collection system is not available currently, a simple system consisting of instrumentation on an existing STEM can be used as a proof of concept which has a S/N of about 255:1, limited by the 8 bit pixel attributes used in the electronics. Use of 24 bit pixel attributes would easily allowthe desired noise range to be attained in the processing instrumentation. The S/N of the scintillator used by the photoelectron sensor is about 106 to 1, well beyond the S/N goal. The trade-off that must be made is the time for acquiring the signal, since the pattern can be obtained in seconds using film plates, compared to 10 to 20 minutes for a pattern to be acquired using the digital scan. Parallel acquisition would, of course, speed up this process immensely.


1933 ◽  
Vol 148 (5) ◽  
pp. 272-273 ◽  
Author(s):  
J. H. Davis
Keyword(s):  

Author(s):  
Bagus Septyanto ◽  
Dian Nurdiana ◽  
Sitti Ahmiatri Saptari

In general, surface positioning using a global satellite navigation system (GNSS). Many satellites transmit radio signals to the surface of the earth and it was detected by receiver sensors into a function of position and time. Radio waves really bad when spreading in water. So, the underwater positioning uses acoustic wave. One type of underwater positioning is USBL. USBL is a positioning system based on measuring the distance and angle. Based on distance and angle, the position of the target in cartesian coordinates can be calculated. In practice, the effect of ship movement is one of the factors that determine the accuracy of the USBL system. Ship movements like a pitch, roll, and orientation that are not defined by the receiver could changes the position of the target in X, Y and Z coordinates. USBL calibration is performed to detect an error angle. USBL calibration is done by two methods. In USBL calibration Single Position obtained orientation correction value is 1.13 ̊ and a scale factor is 0.99025. For USBL Quadrant calibration, pitch correction values is -1.05, Roll -0.02 ̊, Orientation 6.82 ̊ and scale factor 0.9934 are obtained. The quadrant calibration results deccrease the level of error position to 0.276 - 0.289m at a depth of 89m and 0.432m - 0.644m at a depth of 76m


Sign in / Sign up

Export Citation Format

Share Document