scholarly journals Blunt trauma of bone structures of the chest: Computed tomography vs multidetector computed tomography

2013 ◽  
Vol 70 (8) ◽  
pp. 757-761 ◽  
Author(s):  
Kosta Petrovic ◽  
Ivan Turkalj ◽  
Sanja Stojanovic ◽  
Viktorija Vucaj-Cirilovic ◽  
Olivera Nikolic ◽  
...  

Background/Aim. Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). Methods. This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists independently and separately described the findings for 5-mmthick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thinslice examination together which was ultimately considered as a real, true finding. Results. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05) in favor of better display of injury by MDCT examination. Conclusion. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

Author(s):  
Jorge Oviedo-Quirós ◽  
José Campos-Zumbado ◽  
Diana Hernández-Montoya ◽  
María Fernanda Lines-Gutiérrez

A descriptive and exploratory study was carried out with the aim of proposing and validating an open protocol for making 3D impressions of stereolithographic models, which is available to professionals in the area of Dentistry. Nine operators (senior students of the Dentistry degree), without previous experience in the use of software and hardware for 3D printing, divided into two groups were trained through theoretical and practical sessions. The A worked with three helical tomographies (TAC) and the B with three cone beam computed tomography (CBCT), all in DICOM format, converted to STL files. In total, 99 bone structures corresponding to 33 jaws, 33 axis and 33 facial masses-skull bases were analyzed, and a total of 33 jaws were printed in PLA (polylactic acid filament). At the end of the study, no statistically significant difference was found in the implementation of the proposed protocol between the operators, the measurements of the pieces printed by each of them, the gold standard, the TAC and the CBCT, with which not only validated the protocol, but it was possible to determine the resources necessary to carry out this type of 3D printing.


2009 ◽  
Vol 75 (11) ◽  
pp. 1081-1083 ◽  
Author(s):  
Daniela Molena ◽  
Nicole Burr ◽  
Andrea Zucchiatti ◽  
Erik Lovria ◽  
Mark L. Gestring ◽  
...  

With the increased use of chest computed tomography (CT) scan in the initial evaluation of major trauma, findings that were not seen on a chest radiograph (CXR) are increasingly identified. Pneumomediastinum (PM) seen on CXR in blunt trauma patients is considered worrisome for airway and/or esophageal injury. The purpose of this study was to determine the incidence and clinical significance of PM found on CT in blunt trauma patients. Blunt trauma patients admitted to a single Regional Trauma Center over a 2-year period were identified. Records were reviewed for demographics, mechanism, diagnostic evaluations, injuries, and outcome. A total of 2052 patients met study criteria. Fifty-five (2.7%) had PM; 49 patients (89%) had PM identified on CT alone, whereas six patients (11%) had it identified on both CXR and CT. There was no significant difference in gender or age between the two groups. Associated injuries were similar between groups. No patients had tracheobronchial or esophageal injuries. In this study, PM seen on CT was found to have little clinical significance other than as a marker for severe blunt trauma. No patients with airway or esophageal injuries were seen in any of the PM patients.


2021 ◽  
Vol 11 (7) ◽  
pp. 1963-1966
Author(s):  
Limei Bai

Objective: Patients with craniocerebral injury usually accompanied by intracranial hypertension and vomiting, which affect the effect of CT scanning. The aim of this study was to discuss the application effects of gastrointestinal decompression on computed tomography (CT) examination for patients with craniocerebral injury. Methods: A total of 80 patients with craniocerebral injury in our hospital were randomly selected and divided into control and observation groups, 40 cases in each group. The observation group was given gastrointestinal decompression before the CT examination, while the control group received routine examination. The success rate of CT examination, CT scanning effect, examination, and complication during scanning were recorded and compared in two groups. Results: The one-time success rate (100.0%) of CT examination was 100.0% (40/40) in the observation group was significantly higher than the rate in the control group (82.5%, P = 0.034). The CT examination clearly showed in the types of craniocerebral injury, the brain tissue injury, the ventricular compression and the midline displacement. The CT examination time of observation group was shorter than that of control group (P < 0.001), while there was no significant difference in the whole examination time spent on both gastrointestinal decompression operation and CT examination between the two groups (P = 0.301). In the observation group, there was only 1 case of retching, and no cases of vomiting or aspiration during scanning. The incidence of various complications in observation group was significantly lesser than the incidence in control group (P = 0.034). Conclusions: Continue gastrointestinal decompression can significantly reduce the incidence of vomiting and other complication in patients with craniocerebral injury during CT examination, reduce the CT examination time, and improve the success rate of one-time scanning.


2019 ◽  
Vol 30 (5) ◽  
pp. 585-592 ◽  
Author(s):  
Nicola Montemurro ◽  
Paolo Perrini ◽  
Vittoriano Mangini ◽  
Massimo Galli ◽  
Andrea Papini

OBJECTIVEOdontoid process fractures are very common in both young and geriatric patients. The axial trabecular architecture of the dens appears to be crucial for physiological and biomechanical function of the C1–2 joint. The aim of this study is to demonstrate the presence of a Y-shaped trabecular structure of the dens on axial CT and to describe its anatomical and biomechanical implications.METHODSFifty-four C2 odontoid processes in healthy subjects were prospectively examined for the presence of a Y-shaped trabecular structure at the odontocentral synchondrosis level with a dental cone beam CT scan. Length, width, and axial area of the odontoid process were measured in all subjects. In addition, measurements of the one-third right anterior area of the Y-shaped structure were taken.RESULTSThe Y-shaped trabecular structure was found in 79.6% of cases. Length and width of the odontoid process were 13.5 ± 0.6 mm and 11.2 ± 0.9 mm, respectively. The mean area of the odontoid process at the odontocentral synchondrosis was 93.5 ± 4.3 mm2, whereas the mean one-third right anterior area of the odontoid process at the same level was 29.3 ± 2.5 mm2. The mean area of the odontoid process and its length and width were similar in men and women (p > 0.05). No significant difference was found in the mean area of the odontoid process in people older than 65 years (94 ± 4.2 mm2) compared to people younger than 65 years (93.3 ± 4.4 mm2; p > 0.05).CONCLUSIONSThe authors identified a new anatomical entity, named the Y-shaped trabecular structure of the odontoid process, on axial CT scans. This structure appears to be the result of bone transformation induced by the elevated dynamic loading at the C1–2 level. The presence of the Y-shaped structure provides new insights into biomechanical responses of C2 under physiological loading and traumatic conditions.


2019 ◽  
Vol 65 (4) ◽  
pp. 590-595
Author(s):  
Arkadiy Naumenko ◽  
Kseniya Sapova ◽  
Oleg Konoplev ◽  
Svetlana Astashchenko ◽  
Igor Chernushevich

Precise localization and excision of the originating site of a sinonasal inverted papilloma is essential for decreasing tumor recurrence. In this study we evaluated the use of preoperative computed tomography (CT) to pinpoint the attachment/origi-nating sites of the tumor.


Author(s):  
Qinglin Meng ◽  
Mengqi Liu ◽  
Weiwei Deng ◽  
Ke Chen ◽  
Botao Wang ◽  
...  

Background: Calcium-suppressed (CaSupp) technique involving spectral-based images has been used to observe bone marrow edema by removing calcium components from the image. Objective: This study aimed to evaluate the knee articular cartilage using the CaSupp technique in dual-layer detector computed tomography (DLCT). Methods: Twenty-eight healthy participants and two patients with osteoarthritis were enrolled, who underwent DLCT and magnetic resonance imaging (MRI) examination. CaSupp images were reconstructed from spectral-based images using a calcium suppression algorithm and were overlaid conventional CT images for visual evaluation. The morphology of the knee cartilage was evaluated, and the thickness of the articular cartilage was measured on sagittal proton density– weighted and CaSupp images in the patellofemoral compartment. Results: No abnormal signal or density, cartilage defect, and subjacent bone ulceration were observed in the lateral and medial femorotibial compartments and the patellofemoral compartment on MRI images and CaSupp images for the 48 normal knee joints. CaSupp images could clearly identify cartilage thinning, defect, subjacent bone marrow edema, and edema of the infrapatellar fat pad in the same way as MRI images in the three knee joints with osteoarthritis. A significant difference was found in the mean thickness of the patellar cartilage between MRI images and CaSupp images, while the femoral cartilage presented no significant difference in thickness between MRI images and CaSupp images over all 48 knee joints. Conclusion: The present study demonstrated that CaSupp images could effectively be used to perform the visual and quantitative assessment of knee cartilage.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jie Guo ◽  
Xiaofeng Li ◽  
Ruiqi Ma ◽  
Jiang Qian

Abstract Background Postoperative ocular imbalance is an important problem for orbital decompression surgery in thyroid eye disease (TED). The aim of this study was to evaluate the changes in unilateral ocular deviation and duction following orbital decompression and discuss the biomechanics of ocular imbalance. Methods Fifty-four TED patients who underwent unilateral orbital decompression were included. Fifteen patients underwent 1-wall (deep lateral wall) decompression, 18 patients underwent 2-wall (deep lateral and medial wall) decompression and 21 patients underwent 3-wall (deep lateral, medial and inferior wall) decompression. Objective and subjective deviation of the operated eyes were evaluated using the prism test and synoptophore, respectively. Ocular ductions were measured using Hirschberg’s method. The diameters of the extraocular rectus were measured by computed tomography. Results Ocular deviation and duction showed no significant difference after 1-wall decompression (p = 0.25–0.89). Esotropia increased after 2-wall decompression (p = 0.001–0.02), and hypotropia increased after 3-wall decompression (p = 0.02). Adduction increased but abduction decreased following 2-wall and 3-wall decompression (p < 0.05). Infraduction increased following 3-wall decompression (p < 0.001). Additionally, the increase in esotropia was significantly correlated with the increase in adduction and with the decrease in abduction (r = 0.37–0.63, p < 0.05). There were significant correlations between the diameter of the medial rectus and the increase in esotropia, the increase in adduction and the decrease in abduction postoperatively (r = 0.35–0.48, p < 0.05). Conclusions The changes in ocular deviation and duction were different after 1-wall, 2-wall and 3-wall orbital decompression. The increased contractile force of the rectus may be an important reason for strabismus changes after orbital decompression surgery.


Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 541
Author(s):  
Xiao-Chuan Fan ◽  
Lin-Sha Ma ◽  
Li Chen ◽  
Diwakar Singh ◽  
Xiaohui Rausch-Fan ◽  
...  

(1) Background—The aim of the present study was to evaluate the correlation between the temporomandibular joint (TMJ) osseous morphology of normal skeletal pattern individuals with different dental malocclusions by using cone-beam computed tomography (CBCT). (2) Methods—The CBCT images of bilateral TMJs in 67 subjects with skeletal class I and average mandibular angle (26 males and 41 females, age range 20–49 years) were evaluated in this study. The subjects were divided into class I, class II division 1, and class II division 2 according to the molar relationship and retroclination of the maxillary incisors. Angular and linear measurements of TMJ were evaluated and the differences between the groups were statistically analyzed. (3) Results—Intragroup comparisons showed statistical differences for articular eminence inclination, the width of the glenoid fossa, the ratio of the width of the glenoid fossa to the depth of the glenoid fossa, the condylar angle, and the intercondylar angle between the malocclusion groups. The measurements of the glenoid fossa shape showed no significant difference between the left and right sides. Females showed more differences in the morphological parameters of TMJ between the three malocclusion groups than the males. (4) Conclusion—The present study revealed differences in the TMJ osseous morphology between dental class I and class II malocclusions in the normal skeletal pattern.


Author(s):  
Beomcho Jun ◽  
Sunwha Song

Abstract Objective This paper describes the construction of portals for electrode placement during cochlear implantation and emphasises the utility of pre-operative temporal bone three-dimensional computed tomography. Methods Temporal bone three-dimensional computed tomography was used to plan portal creation for electrode insertion. Results Pre-operative temporal bone three-dimensional computed tomography can be used to determine the orientation of temporal bone structures, which is important for mastoidectomy, posterior tympanotomy and cochleostomy, and when using the round window approach. Conclusion It is essential to create appropriate portals (from the mastoid cortex to the cochlea) in a step-by-step manner, to ensure the safe insertion of electrodes into the scala tympani. Pre-operative three-dimensional temporal bone computed tomography is invaluable in this respect.


Sign in / Sign up

Export Citation Format

Share Document