scholarly journals Effect of recasting on the elastic modulus of metal-ceramic systems from nickel-chromium and cobalt-chromium alloys

2007 ◽  
Vol 64 (7) ◽  
pp. 469-473 ◽  
Author(s):  
Nemanja Mirkovic

Background/Aim. Elastic modulus of metal-ceramic systems determines their flexural strength and prevents damages on ceramics during mastication. Recycling of basic alloys is often a clinical practice, despite the possible effects on the quality of the future metal-ceramic dentures. This research was done to establish recasting effects of nickel-chromium and cobalt-chromium alloys on the elastic modulus of metalceramic systems in making fixed partial dentures. Methods. The research was performed as an experimental study. Six metal-ceramic samples of nickel-chromium alloy (Wiron 99) and cobalt-chromium alloy (Wirobond C) were made. Alloy residues were recycled through twelve casting generations with the addition of 50% of new alloy on the occasion of every recasting. Three- point bending test was used to determine elastic modulus, recommended by the standard ISO 9693:1999. Fracture load for damaging ceramic layer was recorded on the universal testing machine (Zwick, type 1464), with the speed of 0,05 mm/min. Results. The results of this research revealed significant differences between elasticity modules of metal-ceramic samples in every examined recycle generation. Recasting had negative effect on the elastic modulus of the examined alloys. This research showed the slight linear reduction of elastic modulus up to the 6th generation of recycling. After the 6th recycling there was a sudden fall of elastic modulus. Conclusion. Recasting of nickelchromium and cobalt-chromium alloys is not recommended because of the reduced elastic modulus of these alloys. Instead of reusing previously recasted alloys, the alloy residues should be returned to the manufacturer. .

2007 ◽  
Vol 64 (4) ◽  
pp. 241-245 ◽  
Author(s):  
Nemanja Mirkovic

Background/Aim. Metal-ceramic bond strength and alloys' elastic modulus clearly determine the potential of alloy application, because the ceramic integrity during mastication depends on these two characteristics. The aim of this study was to evaluate metal-ceramic bond strength and elastic modulus of cobalt-chromium alloys in making porcelainfused- to-metal restorations, regarding the application of the most frequent nickel-chromium alloy. Methods. The research was performed as an experimental study. Six metalceramic samples were made from nickel-chromium alloy (Wiron 99) and cobalt-chromium alloy (Wirobond C), according to the manufactures manuals and instructions from ISO 9693: 1996. Three-point bending test was performed up to the ceramic fracture. The fracture load was measured on an universal testing machine (Zwick, type 1464), with cross-head speed of 0,05mm/min. Results. The results of this study confirmed the significant differences between the metal-ceramic bond strength (p < 0.01) and elastic modulus (p < 0.001) of nickel-chromium and cobalt-chromium alloys, where cobalt-chromium alloys showed higher values for both tested parameters. Conclusion. Cobalt-chromium metal-ceramic alloys can successfully replace nickel-chromium alloys, especially for fabrication of long-span metal-ceramic bridges due to the great flexural strength.


2008 ◽  
Vol 65 (5) ◽  
pp. 365-369 ◽  
Author(s):  
Nemanja Mirkovic ◽  
Miroslav Draganjac ◽  
Dragoslav Stamenkovic ◽  
Ljubisa Ristic

Introduction/Aim. This research was done to establish recasting effects of nickel-chromium and cobalt-chromium alloys on the thickness of their metal-ceramic interface in making fixed partial dentures. Metal-ceramic interface determines their functional integrity and prevents damages on ceramics during mastication. Investigation of metal-ceramic samples is supposed to show if base metal alloys for metalceramics are successfully recycled without any risk of reduction of metal-ceramic interface thickness. Methods. The research was performed as an experimental study. Per six metal-ceramic samples of nickel-chromium alloy (Wiron99) and cobalt-chromium alloy (Wirobond C) were made each. Alloy residues were recycled through twelve casting generations with the addition of 50% of new alloy on the occasion of every recasting. Analysis Energy Dispersive X-ray (EDX) (Oxford Instruments) and Scanning Electon Microscop (SEM) analysis (JEOL) were used to determine thickness of metal-ceramic interface together with PC Software for quantification of visual information's (KVI POPOVAC). Results. Results of this research introduced significant differences between thickness of metal-ceramic interface in every examined recycle generation. Recasting had negative effect on thickness of metal-ceramic interface of the examined alloys. This research showed almost linear reduction of elastic modulus up to the 12th generation of recycling. Conclusion. Recasting of nickel-chromium and cobaltchromium alloys is not recommended because of reduced thickness of metal-ceramic interface of these alloys. Instead of recycling, the alloy residues should be returned to the manufacturers.


2018 ◽  
Vol 72 (3) ◽  
pp. 149-156
Author(s):  
Vladimir Stefanovic ◽  
Zoran Lazic ◽  
Nemanja Mirkovic ◽  
Ervin Taso ◽  
Nenad Simeunovic ◽  
...  

This research was performed to establish recasting effects of nickel-chromium dental alloys on the composition of their metal-ceramic interface in making fixed partial dentures. The metal-ceramic interface determines denture functional integrity and prevents damages on ceramics during mastication. Recycling of nickel-chromium alloys is often a practice, without detailed knowledge about possible effects on the composition of the metal-ceramic interface. Investigation of metal-ceramic samples is intended to show if base metal alloys for metal-ceramics are successfully recycled without any composition change in the metal-ceramic interface. The research was performed as an experimental study in which six metal-ceramic samples of nickel-chromium alloy ?Wiron 99? (Bego, Germany) were made. Alloy residues were recycled through twelve casting generations with the addition of 50 wt% of the new alloy on the occasion of every recasting. EDX analysis was performed by using the ?Inca X Sight? apparatus (Oxford Instruments, UK) and a SEM device JSM 6460 LV (JEOL, Japan). This appliance was used in conjunction with the PC software for quantification of chemical elements in order to determine the composition of metal-ceramic interfaces. Results of this research revealed significant differences between compositions of metal-ceramic interfaces in every examined recycle generation. Recasting had a negative effect on alloy components, which concentration is decreasing in the metal-ceramic junction zone. The concentration of cerium in the intermediate phase decreased the most, followed by concentrations of niobium, molybdenum, nickel and chromium. Results showed a permanent reduction of metal components up to the 12th generation of recycling. Cerium concentration (wt%) decreased from 28 to 16.26 %, nickel concentration from 3.31 to 1.82 % and chromium concentration from 2.95 to 2.03 %. Similarly, the molybdenum content decreased from 8.71to 4.68 wt%, while that of niobium from 9.82 to 3.97 wt%. Therefore, recasting of nickel-chromium alloys is not recommended because of changed composition of the metal-ceramic interface of these alloys.


2006 ◽  
Vol 17 (1) ◽  
pp. 24-28 ◽  
Author(s):  
Alfredo Julio Fernandes Neto ◽  
Heitor Panzeri ◽  
Flavio Domingues Neves ◽  
Ricardo Alves do Prado ◽  
Gustavo Mendonça

Ceramometal bond strength has played an important role for the replacement of gold alloys by nickel-chromium alloys in dentistry. This study evaluated the metal/porcelain bond strength of three ceramic systems (Vita VMK 88, Williams and Duceram) associated with three nickel-chromium alloys (Durabond, Lite Cast B and Resistal P) and one experimental cobalt-chromium-titanium alloy. Thirty cast cylinder specimens (15 mm in height; 6 mm in diameter) were obtained for each alloy, in away that 10 specimens of each alloy were tested with each porcelain. Bond strength was measured with an Emic screw-driven mechanical testing machine by applying parallel shear forces to the specimens until fracture. Kruskal-Wallis and Mann-Whitney U tests were used for statistical analysis of the alloy/ceramic combinations (p<0.05). Resistal P/Duceram had significantly higher bond strength (44.38±9.12 MPa) (p<0.05) than the other combinations, except for Co-Cr-Ti alloy/Vita VMK 88 (38.41±12.64 MPa). The association of the experimental Co-Cr-Ti alloy with Williams porcelain had significantly higher bond strength (28.20±3.86 MPa) than the combination of other alloys with the same porcelain (p<0.05). Based of these results and within the limitations of an in vitro study, it may be concluded that the bond strength of the three ceramic systems to the Ni-Cr and Co-Cr-Ti alloys varied significantly, indicating that metal/ceramic compatibility was very important to the bond strength.


2017 ◽  
Vol 18 (9) ◽  
pp. 837-841
Author(s):  
T Meenakshi ◽  
Munagapati Bharathi ◽  
Jayasree Komala

ABSTRACT Aim The aim of this study was to evaluate the effect of recasting base metal alloy on the metal–ceramic bond strength. Materials and methods A total of 60 test samples were prepared from new and recast nickel–chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A2, A3, A4, and A5 were prepared from 50% new alloy and 50% casting remnants (sprue and buttons) of the previous group by weight. All these samples were coated with ceramic (IPS d.SIGN and Ivoclar-Vivadent), and samples were then subjected to three-point bending test to evaluate metal–ceramic bond strength. Results The values were analyzed using one-way analysis of variance and Tukey's post hoc test. The mean bond strength of group A0 was higher than that of groups A1, A2, A3, A4, and A5. Conclusion Metal–ceramic bond strength decreased significantly with multiple recastings. Clinical significance Bond strength between metal and ceramic is a crucial factor for the clinical performance of metal–ceramic restorations. Recasting of alloys may affect the metal oxide layer composition and thickness of metal–ceramic interface, and thereby the metal–ceramic bond. How to cite this article Meenakshi T, Bharathi M, Komala J. Evaluation of the Effect of recasting Nickel–chromium Base Metal Alloy on the Metal–ceramic Bond Strength: An in vitro Study. J Contemp Dent Pract 2017;18(9):837-841.


Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 959
Author(s):  
Verónica Rodríguez ◽  
Celia Tobar ◽  
Carlos López-Suárez ◽  
Jesús Peláez ◽  
María J. Suárez

The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.


2015 ◽  
Vol 26 (3) ◽  
pp. 258-262 ◽  
Author(s):  
Renato Sussumu Nishioka ◽  
Luis Gustavo Oliveira de Vasconcellos ◽  
Renata Pilli Jóias ◽  
Sigmar de Mello Rode

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.


2019 ◽  
Vol 18 ◽  
pp. e191443
Author(s):  
Laise Pena Braga Monteiro ◽  
Issae Sousa Sano ◽  
Suelen Reis Cunha ◽  
Eliza Burlamaqui Klautau ◽  
Bruno Pereira Alves

Aim: The aim of this study was to evaluate the influence of tungsten inert gas (TIG) welding and airborne particle abrasion using aluminum oxide particles on the flexural strength of a joint between ceramic and cobalt-chromium alloys. Methods: The specimens were cast and welded using TIG, then divided into 6 groups (n = 10) and subjected to blasting with 250 μm, 100 μm, and 50 μm aluminum oxide particles. Ceramic systems were applied to the central part of all specimens. A three-point bending test using a velocity of 0.5 mm/m was performed on the specimens to measure flexural strength. Data were analyzed using two-way analysis of variance and Tukey’s test. Results: TIG welding demonstrated the lowest resistance compared with the non-welded groups. Airborne particle abrasion using 250 μm aluminum oxide particles demonstrated greater resistance in the welded groups (p < 0.05). Mixed faults were found in all specimens. Conclusion: TIG welding decreased the bond strength, and the particle size of aluminum oxide did not affect the metal-ceramic bond in groups without TIG welding.


Sign in / Sign up

Export Citation Format

Share Document