scholarly journals A CFD investigation and heat transfer augmentation of double pipe heat exchanger by employing helical baffles on shell and tube side

2021 ◽  
pp. 300-300
Author(s):  
Sobhanadri Anantha ◽  
Senthilkumar Gnanamani ◽  
Vivekanandan Mahendran ◽  
Venkatesh Rathinavelu ◽  
Ramkumar Rajagopal ◽  
...  

The inclusion of baffles in a double pipe heat exchanger is becoming increasingly important as it improves the heat exchanger's performance. CFD analysis is used in this paper to investigate the performance of double pipe heat exchangers with and without helical baffles on both shell tube sides. The 3D Computation Fluid Dynamics (CFD) model was created in Solid Works, and the FloEFD software was used to analyze the conjugate Heat Transfer between the heat exchanger's tube and shell sides. Heat transfer characteristic like Outlet temperature of shell and tube are investigated along with pressure drop on shell and tube side. Based on CFD results of Double Pipe Heat exchanger with helical baffle on both shell side and tube side (Type 4) gives the better results than the other type of heat exchangers with an increased pressure drop than the others, results reveals that type 4 outlet temperature of shell side is 8% higher and on tube side it is 5.5% higher, also pressure drop on shell side is 12% higher and on tube side it is 42% higher than the other types.

2006 ◽  
Vol 129 (9) ◽  
pp. 1277-1285 ◽  
Author(s):  
Qiu-wang Wang ◽  
Gong-nan Xie ◽  
Bo-tao Peng ◽  
Min Zeng

The heat transfer and pressure drop of three types of shell-and-tube heat exchangers, one with conventional segmental baffles and the other two with continuous helical baffles, were experimentally measured with water flowing in the tube side and oil flowing in the shell side. The genetic algorithm has been used to determine the coefficients of correlations. It is shown that under the identical mass flow, a heat exchanger with continuous helical baffles offers higher heat transfer coefficients and pressure drop than that of a heat exchanger with segmental baffles, while the shell structure of the side-in-side-out model offers better performance than that of the middle-in-middle-out model. The predicted heat transfer rates and friction factors by means of the genetic algorithm provide a closer fit to experimental data than those determined by regression analysis. The predicted corrections of heat transfer and flow performance in the shell sides may be used in engineering applications and comprehensive study. It is recommended that the genetic algorithm can be used to handle more complicated problems and to obtain the optimal correlations.


2007 ◽  
Vol 129 (10) ◽  
pp. 1425-1431 ◽  
Author(s):  
B. Peng ◽  
Q. W. Wang ◽  
C. Zhang ◽  
G. N. Xie ◽  
L. Q. Luo ◽  
...  

Two shell-and-tube heat exchangers (STHXs) using continuous helical baffles instead of segmental baffles used in conventional STHXs were proposed, designed, and tested in this study. The two proposed STHXs have the same tube bundle but different shell configurations. The flow pattern in the shell side of the heat exchanger with continuous helical baffles was forced to be rotational and helical due to the geometry of the continuous helical baffles, which results in a significant increase in heat transfer coefficient per unit pressure drop in the heat exchanger. Properly designed continuous helical baffles can reduce fouling in the shell side and prevent the flow-induced vibration as well. The performance of the proposed STHXs was studied experimentally in this work. The heat transfer coefficient and pressure drop in the new STHXs were compared with those in the STHX with segmental baffles. The results indicate that the use of continuous helical baffles results in nearly 10% increase in heat transfer coefficient compared with that of conventional segmental baffles for the same shell-side pressure drop. Based on the experimental data, the nondimensional correlations for heat transfer coefficient and pressure drop were developed for the proposed continuous helical baffle heat exchangers with different shell configurations, which might be useful for industrial applications and further study of continuous helical baffle heat exchangers. This paper also presents a simple and feasible method to fabricate continuous helical baffles used for STHXs.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Swanand Gaikwad ◽  
Ashish Parmar

AbstractHeat exchangers possess a significant role in energy transmission and energy generation in most industries. In this work, a three-dimensional simulation has been carried out of a shell and tube heat exchanger (STHX) consisting of segmental baffles. The investigation involves using the commercial code of ANSYS CFX, which incorporates the modeling, meshing, and usage of the Finite Element Method to yield numerical results. Much work is available in the literature regarding the effect of baffle cut and baffle spacing as two different entities, but some uncertainty pertains when we discuss the combination of these two parameters. This study aims to find an appropriate mix of baffle cut and baffle spacing for the efficient functioning of a shell and tube heat exchanger. Two parameters are tested: the baffle cuts at 30, 35, 40% of the shell-inside diameter, and the baffle spacing’s to fit 6,8,10 baffles within the heat exchanger. The numerical results showed the role of the studied parameters on the shell side heat transfer coefficient and the pressure drop in the shell and tube heat exchanger. The investigation shows an increase in the shell side heat transfer coefficient of 13.13% when going from 6 to 8 baffle configuration and a 23.10% acclivity for the change of six baffles to 10, for a specific baffle cut. Evidence also shows a rise in the pressure drop with an increase in the baffle spacing from the ranges of 44–46.79%, which can be controlled by managing the baffle cut provided.


2019 ◽  
Vol 140 ◽  
pp. 580-591 ◽  
Author(s):  
Ganesh Kumar Poongavanam ◽  
Balaji Kumar ◽  
Sakthivadivel Duraisamy ◽  
Karthik Panchabikesan ◽  
Velraj Ramalingam

2021 ◽  
Author(s):  
praveen math

Abstract Shell and Tube heat exchangers are having special importance in boilers, oil coolers, condensers, pre-heaters. They are also widely used in process applications as well as the refrigeration and air conditioning industry. The robustness and medium weighted shape of Shell and Tube heat exchangers make them well suited for high pressure operations. The aim of this study is to experiment, validate and to provide design suggestion to optimize the shell and tube heat exchanger (STHE). The heat exchanger is made of acrylic material with 2 baffles and 7 tubes made of stainless steel. Hot fluid flows inside the tube and cold fluid flows over the tube in the shell. 4 K-type thermocouples were used to read the hot and cold fluids inlet and outlet temperatures. Experiments were carried out for various combinations of hot and cold water flow rates with different hot water inlet temperatures. The flow conditions are limited to the lab size model of the experimental setup. A commercial CFD code was used to study the thermal and hydraulic flow field inside the shell and tubes. CFD methodology is developed to appropriately represent the flow physics and the procedure is validated with the experimental results. Turbulent flow in tube side is observed for all flow conditions, while the shell side has laminar flow except for extreme hot water temperatures. Hence transition k-kl-omega model was used to predict the flow better for transition cases. Realizable k- epsilon model with non-equilibrium wall function was used for turbulent cases. Temperature and velocity profiles are examined in detail and observed that the flow remains almost uniform to the tubes thus limiting heat transfer. Approximately 2/3 rd of the shell side flow does not surround the tubes due to biased flow contributing to reduced overall heat transfer and increased pressure loss. On the basis of these findings an attempt has been made to enhance the heat transfer by inducing turbulence in the shel l side flow. The two baffles were rotated in opposite direction to each other to achieve more circulation in the shell side flow and provide more contact with tube surface. Various positions of the baffles were simulated and studied using CFD analysis and th e results are summarized with respect to heat transfer and pressure loss.


2013 ◽  
Vol 655-657 ◽  
pp. 461-464 ◽  
Author(s):  
Su Fang Song

The three-dimensional model of heat exchangers with continuous helical baffles was built. The fluid flow dynamics and heat transfer of shell side in the helical baffled heat exchanger were simulated and calculated. The velocity, pressure and temperature distributions were achieved. The simulation shows that with the same baffle pitch, shell-side heat transfer coefficient increased by 25% and the pressure drop decreases by 18% in helical baffled heat exchanger compared with segmental helical baffles. With the analyzing of the flow and heat transfer in heat exchanger in 5 different inclination angles from 11°to 21°, it can be found that both shell side heat transfer coefficient and pressure drop will reduce respectively by 86% and 52% with the increases 11°to 21°of the inclination angles. Numerical simulation provided reliable theoretical reference for further engineering research of heat exchanger with helical baffles.


2019 ◽  
Vol 55 (6) ◽  
pp. 1769-1781 ◽  
Author(s):  
H. Arya ◽  
M. M. Sarafraz ◽  
O. Pourmehran ◽  
M. Arjomandi

2017 ◽  
Vol 57 (2) ◽  
pp. 125 ◽  
Author(s):  
Putu Wijaya Sunu ◽  
I Made Rasta

This investigation was performed to experimentally investigate the enhancement of heat transfer and the friction of an annulus in a double pipe heat exchanger system with rectangular grooves in the turbulent flow regime. The shell is made of acrylic and its diameter is 28 mm. The tube is made of aluminium and its diameter is 20 mm. Grooves were incised in the annulus room with a circumferential pattern, with a groove space of 2 mm, a distance between the grooves of 8mm and a groove height of 0.3 mm. The experiments consist of temperature and pressure measurement and a flow visualization. Throughout the investigation, the cold fluid flowed in the annulus room. The Reynold number of cold fluid varied from about 31981 to 43601 in a counter flow condition. The volume flow rate of hot fluid remains constant with Reynold number about 30904. Result showed the effect of grooves, which are applied in the annulus room. The grooves induce the pressure drop, the pressure drop in the grooved annulus was greater by about 15.88% to 16.72% than the one in the smooth annulus. The total heat transfer enhancement is of 1.09–1.11. Moreover, the use of grooves in the annulus of the heat exchanger not only increase the heat transfer process, but also increase the pressure drop, which is related to the friction factor.


2019 ◽  
Vol 345 ◽  
pp. 815-824 ◽  
Author(s):  
Ganesh Kumar Poongavanam ◽  
Karthik Panchabikesan ◽  
Renuka Murugesan ◽  
Sakthivadivel Duraisamy ◽  
Velraj Ramalingam

Sign in / Sign up

Export Citation Format

Share Document